DOI QR코드

DOI QR Code

Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report

  • Andrabi, Syed Mukhtar-Un-Nisar (Department of Conservative Dentistry, Dr. Z. A. Dental College, Aligarh Muslim University) ;
  • Kumar, Ashok (Department of Conservative Dentistry, Dr. Z. A. Dental College, Aligarh Muslim University) ;
  • Iftekhar, Huma (Department of Conservative Dentistry, Dr. Z. A. Dental College, Aligarh Muslim University) ;
  • Alam, Sharique (Department of Conservative Dentistry, Dr. Z. A. Dental College, Aligarh Muslim University)
  • Received : 2013.02.22
  • Accepted : 2013.04.28
  • Published : 2013.05.31

Abstract

During root canal preparation procedures, the potential for instrument breakage is always present. When instrument breakage occurs, it leads to anxiety of the clinician and as well as a metallic obstruction of the canal which hinders further cleaning and shaping. Separated instruments must always be attempted for retrieval and if retrieval is not possible bypass should be tried. With the increased use of nickel-titanium (NiTi) instruments the incidence of separated instruments has increased. A considerable amount of research has been done to understand the various factors related to the fracture of NiTi instruments to minimize its occurrence. This paper presents a review of the literature regarding the fracture of NiTi instruments and also describes a case report showing the use of a modified 18-guage needle and cyanoacrylate glue to retrieve a separated NiTi instrument from the mesiolingual canal of a mandibular first molar.

Keywords

References

  1. Hulsmann M. Removal of silver cones and fractured instruments using the canal finder system. J Endod 1990;16:596-600. https://doi.org/10.1016/S0099-2399(07)80203-2
  2. Fors UG, Berg JO. Endodontic treatment of root canals obstructed by foreign objects. Int Endod J 1986;19:2-10. https://doi.org/10.1111/j.1365-2591.1986.tb00884.x
  3. Vaudt J, Bitter K, Neumann K, Kielbassa AM. Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments. Int Endod J 2009;42:22-33. https://doi.org/10.1111/j.1365-2591.2008.01489.x
  4. Bonaccorso A, Cantatore G, Condorelli GG, Schafer E, Tripi TR. Shaping ability of four nickel-titanium rotary instruments in simulated S-shaped canals. J Endod 2009;35:883-886. https://doi.org/10.1016/j.joen.2009.03.007
  5. Carvalho LA, Bonetti I, Borges MA. A comparison of molar root canal preparation using stainless-steel and Nickel-Titanium instruments. J Endod 1999;25:807-810. https://doi.org/10.1016/S0099-2399(99)80302-1
  6. Sattapan B, Nervo GT, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod 2000;26:161-165. https://doi.org/10.1097/00004770-200003000-00008
  7. Hulsmann M, Schinkel I. Influence of several factors on the success or failure of removal of fractured instruments from the root canal. Endod Dent Traumatol 1999;15:252-258. https://doi.org/10.1111/j.1600-9657.1999.tb00783.x
  8. Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J 2000;33:297-310. https://doi.org/10.1046/j.1365-2591.2000.00339.x
  9. Plotino G, Pameijer CH, Grande NM, Somma F. Ultrasonics in endodontics: a review of the literature. J Endod 2007;33:81-95. https://doi.org/10.1016/j.joen.2006.10.008
  10. Cuje J, Bargholz C, Hulsmann M. The outcome of retained instrument removal in a specialist practice. Int Endod J 2010;43:545-554. https://doi.org/10.1111/j.1365-2591.2009.01652.x
  11. Alapati SB, Brantley WA, Svec TA, Powers JM, Nusstein JM, Daehn GS. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 2005;31:40-43.
  12. Askeland DR, Phule PF. The science and engineering of materials. 4th ed. California: Brooks/Cole-Thomson Learning; 2003.
  13. Spanaki-Voreadi AP, Kerezoudis NP, Zinelis S. Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: fractographic analysis. Int Endod J 2006;39:171-178. https://doi.org/10.1111/j.1365-2591.2006.01065.x
  14. Parashos P, Gordon I, Messer HH. Factors influencing defects of rotary nickel titanium endodontic instruments after clinical use. J Endod 2004;30:722-725. https://doi.org/10.1097/01.DON.0000129963.42882.C9
  15. Souter NJ, Messer HH. Complications associated with fractured file removal using an ultrasonic technique. J Endod 2005;31:450-452. https://doi.org/10.1097/01.don.0000148148.98255.15
  16. Torabinejad M, Lemon RR. Procedural accidents. In: Walton RE, Torabinejad M, eds. Principles and practice of endodontics, 3rd ed. Philadelphia: Saunders; 2002. p310-330.
  17. Spili P, Parashos P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod 2005;31:845-850. https://doi.org/10.1097/01.don.0000164127.62864.7c
  18. Ruddle CJ. Nonsurgical retreatment. J Endod 2004;30:827-845. https://doi.org/10.1097/01.don.0000145033.15701.2d

Cited by

  1. Prevention and management of fractured instruments in endodontic treatment vol.5, pp.1, 2015, https://doi.org/10.5412/wjsp.v5.i1.82
  2. The top 10 most-cited articles on the management of fractured instruments: a bibliometric analysis vol.44, pp.1, 2019, https://doi.org/10.5395/rde.2019.44.e2
  3. A Method for retrieving Endodontic or Atypical Nonendodontic separated Instruments from the Root Canal: A Report of Two Cases vol.15, pp.6, 2013, https://doi.org/10.5005/jp-journals-10024-1615
  4. A Method for retrieving Endodontic or Atypical Nonendodontic separated Instruments from the Root Canal: A Report of Two Cases vol.15, pp.6, 2013, https://doi.org/10.5005/jp-journals-10024-1615
  5. Mechanical Properties of Glide Path Preparation Instruments with Different Pitch Lengths vol.44, pp.5, 2013, https://doi.org/10.1016/j.joen.2018.01.022
  6. Removing Fractured Endodontic NiTi Instruments with a Tube Technique: Influence of Pre-Treatment with Various Agents on Adhesive Forces In Vitro vol.13, pp.1, 2013, https://doi.org/10.3390/ma13010144