DOI QR코드

DOI QR Code

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화

  • Received : 2013.06.07
  • Accepted : 2013.06.24
  • Published : 2013.06.30

Abstract

Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Keywords

References

  1. Korea Water Resources Corporation. Evaluation of an applicability of alternative disinfectants on water and wastewater treatment process. 2004.
  2. Steen PV, Brenner A, Shabtal Y, Oron G. The effect of environmental conditions on fecal caliform decay in post-treatment of UASB reactor effluent. Wat Sci Tech. 2000; 42(10-11): 111-118.
  3. Water Environment Federation. Wastewater disinfection: Manual of Practice. 1996; FD-10 Va: 37-39.
  4. Beak YS, Shon JS. Studies on the effect of water quality parameters on total coliform concentration in sewage effluents. J Kor Soc Wat Qual. 2006; 22(1): 166-171.
  5. Korea Ministry of Environment. General guidelines for business transactions handled the installation of the sewage treatment plant disinfection facilities. 2002.
  6. Beck YS, Song MH, Jung KH, Kwon DS, Lee GD. Formation characteristics of disinfection by-products using chlorine disinfection in sewage effluent. J Kor Soc Wat Qual. 2004; 20(3): 275-280.
  7. Chung GS. A study on the disinfection of coliformgroup in the effluent of sewage plant by high voltage electric field treatment. [dissertation].[Cheju]: Cheju National University; 2004.
  8. Korea Ministry of Environment. Public sewerage system installation business guide. 2007.
  9. Lee MG, Chung GS, Kam SK. A study on the disinfection of coliform group in the effluent of sewage plant by high voltage electric field treatment. J Environ Sci. 2008; 17(7): 817-826. https://doi.org/10.5322/JES.2008.17.7.817
  10. JJung KW, Yoon CG. Photoreactivation study of wastewater treatment effluent disinfected by UVirradiation for water reuse. Kor Soc of Wat and Wastewat Kor Soc on Wat Environ 2003 Joint Spring conference Proceeding. 2003. p105-108.
  11. Antoniadis N, Poulios I, Nikolakaki E, Mantzzavinos D. Sonochemical disinfection of municipal wastewater. J Hazard Mater. 2007; 146: 492-495. https://doi.org/10.1016/j.jhazmat.2007.04.065
  12. Kim DS, Park YS. E. coli disinfection using multi plasma reactor. J Environ Health Sci. 2013; 39(2): 187-195. https://doi.org/10.5668/JEHS.2013.39.2.187
  13. Kim DS, Park, YS. Effect of operating parameters on electrochemical degradation of Rhodamine B by three-dimensional electrode. J Environ Health Sci. 2009; 35(4): 295-303. https://doi.org/10.5668/JEHS.2009.35.4.295
  14. Ryu SM, Park HK, Lee BJ. Study on the characteristics of dielectric barrier discharging system and usability as a disinfectant. J Kor Soc Wat Wastewat. 2004; 18(4): 529-536.
  15. Kim DS, Park YS. A study on the microorganism disinfection of characteristics of discharged water of dielectric barrier discharge plasma. J Environ Health Sci. 2012; 38(2): 159-166. https://doi.org/10.5668/JEHS.2012.38.2.159
  16. Duk San Science. Availilable: http://www.dslab.co.kr/src/products/products_detail.php?product_mst_id=0460_00002[accessed 20 May 2013].
  17. Tezcanli-Guyer G, Ince NH. Degradation and toxicity reduction of textile dyestuff by ultrasound. Ultraso Sonochem. 2003; 10: 235-240. https://doi.org/10.1016/S1350-4177(03)00089-0
  18. Njatawidjaja E, Sugiarto AT, Ohshima T, Sato M. Decoloration of electrostatically atomized organic dye by the pulsed streamer corona discharge. J Electrostat. 2005; 63: 353-359. https://doi.org/10.1016/j.elstat.2004.12.001
  19. Park YS, Kim DS. The generation of $H_2O_2$ and $O_3$ in oxygen plasma processes. Kor Environ Soc Sci. 2011 Annual Conference Proceeding. 2011; 20: 180-182.

Cited by

  1. Inactivation of Sewage Microorganisms using Multi-Plasma Process vol.23, pp.5, 2014, https://doi.org/10.5322/JESI.2014.5.985