Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT

PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성

  • Ham, Jun Cheol (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kang, Chun Koo (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Cho, Seok Won (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Bahn, Young Kag (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lee, Seung Jae (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lim, Han Sang (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lee, Chang Ho (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System)
  • 함준철 (연세의료원 세브란스병원 핵의학과) ;
  • 강천구 (연세의료원 세브란스병원 핵의학과) ;
  • 조석원 (연세의료원 세브란스병원 핵의학과) ;
  • 반영각 (연세의료원 세브란스병원 핵의학과) ;
  • 이승재 (연세의료원 세브란스병원 핵의학과) ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 이창호 (연세의료원 세브란스병원 핵의학과)
  • Received : 2013.02.05
  • Accepted : 2013.04.09
  • Published : 2013.04.27

Abstract

Purpose: Currently, decrement revision using LDCT is used in PET/CT. But cold artifacts are often found in decrement revision image by mismatch between LDCT image and Emission image near diaphragm due to patient's respiration. This research studied reduction of cold artifact by patient's respiration using CTAC Shift among revision methods. Materials and Methods: From March to September in 2012, 30 patients who had cold artifacts by respiration were targeted using PET/CT Discovery 600 (GE Healthcare, MI, USA) equipment. Patients with cold artifacts were additionally scan in diaphragm area, and the image shown cold artifacts at whole body test were revised using CTAC Shift. Cold artifacts including image, additional scan image and CTAC Shift revision image were evaluated as 1~5 points with naked eye by one nuclear medicine expert, 4 radiotechnologists with over 5 year experience. Also, standard uptake value of 3 images was compared using paired t-test. Results: Additional scan image and CTAC Shift revision image received relatively higher score in naked eye evaluation than cold artifacts including image. The additional scan image and CTAC Shift revision image had high correlation as the results of ANOVA test of standard uptake value and did not show significant difference. Conclusion: When cold artifacts are appeared by patient's respiration at PET/CT, it causes not only patient inconvenience but troubles in test schedule due to extra radiation exposure and time consumption by additional scan. But if CTAC Shift revision image can be acquired with out additional scan, it is considered to be helped in exact diagnosis without unnecessary extra radiation exposure and additional scan.

현재 PET/CT 검사에서 저선량 CT를 이용한 감쇠 보정을 사용하고 있다. 하지만 환자 호흡으로 인한 횡격막 부근의 저선량 CT 영상과 Emission 영상의 불일치로 감쇠 보정영상에서 Artifact가 발생하는 경우가 있다. 본 연구는 보정방법 중 CTAC Shift를 이용하여 환자의 호흡에 의한 Artifact의 감소를 연구했다. 2012년 3월부터 9월까지 PET/CT Discovery 600 (GE Healthcare, MI, USA) 장비를 이용하여 호흡에 의한 Artifact가 발생한 환자 30명을 대상으로 했다. Artifact가 발생한 환자는 횡격막 부분을 추가검사하였고, 전신 검사 시 Artifact가 발생한 영상을 CTAC Shift를 이용하여 보정했다. Artifact 발생 영상, 추가 검사영상, CTAC Shift 보정 영상의 육안적 평가는 핵의학 전문의 1명과 5년 이상 근무한 방사선사 4명에 의해 1-5점으로 나누어 평가했다. 또한 각 영상의 표준섭취화 계수를 ANOVA를 이용하여 비교했다. Artifact 발생 영상에 비해 추가 검사 영상과 CTAC Shift 보정 영상은 육안적 평가에서 상대적으로 높은 점수를 받았다. 추가 검사 영상과 CTAC Shift 보정 영상은 표준섭취화 계수의 ANOVA 결과, 높은 상관관계를 갖고 있으며, 유의한 차이를 보이지 않았다. PET/CT 검사 시 환자의 호흡에 의한 Artifact가 발생 할 경우 추가 검사로 인한 검사 시간이 증가하여 환자의 불편 뿐 아니라 피폭도 증가한다. 하지만 추가 검사 없이 CTAC Shift를 이용하여 보정된 영상을 획득한다면 불필요한 피폭 및 추가 검사도 감소하며, 정확한 진단에 도움을 줄 것으로 사료된다.

Keywords