DOI QR코드

DOI QR Code

Test Result on Embedded Steel Column-to-Foundation Connection for Modular Unit Structural System

유닛 모듈러 기둥 매입형 기초 접합부에 대한 실험 연구

  • Received : 2014.03.13
  • Accepted : 2014.08.30
  • Published : 2014.12.27

Abstract

A steel modular unit structural system has been used increasingly for mid and high-rise buildings, since the building can be easily constructed by assembling the pre-made modular unit structures. For this structural system, each modular unit structures have to be properly connected to the foundation to transfer the axial force and the bending moment that are generated from external load to the ground. In this study, a new type of the embedded steel column-to-foundation connection was proposed, and its flexural behavior was evaluated through a series of experimental study. Five full scale specimens for the proposed connections were constructed and tested. The effect of the main parameters that affect the flexural behavior of the proposed connection, such as embedment length and shape of end plate, were studied. From the results, it was found that the flexural stiffness of the proposed connection was higher than that of the semi-rigid connection for all test specimens, and 200 mm of embedment length was proper for the given test specimens in this study.

골조 유닛 모듈러 구조 형식은 기 제작된 유닛 구조물을 적층하여 건물을 보다 간편히 건설을 할 수 있어 중, 고층 건물에 적용이 확대되고 있다. 이러한 유닛 모듈러 구조 형식은 외력에 의하여 발생하는 축력과 휨모멘트를 지반에 잘 전달시켜야 함으로 각각의 유닛구조물은 기초와 적절히 연결되어야 한다. 본 연구에서는 새로운 형태의 매입형 유닛-기초 접합부를 제안하였으며, 제안된 접합부의 성능을 일련의 실험 연구를 통하여 평가하였다. 총 5개의 실물 크기의 실험체를 제작하여 실험을 수행하였으며, 매입 길이와 엔드 플레이트와 같은 제안된 유닛-기초 접합부의 휨거동에 영향을 미칠 수 있는 인자들의 영향을 살펴보았다. 실험결과, 모든 실험체에서 강성은 최소한 반강접의 강성을 상회하는 것으로 나타났으며, 기둥의 매입길이는 본 연구에서 수행한 실험체에서 약 200mm가 적절한 것으로 파악되었다.

Keywords

References

  1. Annan, C.D., Youssef, M.A., and Naggar, M.H. (2009) Experimental Evaluation of the Seismic Performance of Modular Steel-Braced Frames, Eng. Struct., Vol.31, pp. 1435-1446. https://doi.org/10.1016/j.engstruct.2009.02.024
  2. Lawson, R.M., Ogden, R.G., and Bergin, R. (2012) Application of Modular Construction in High-Rise Buildings, J. Archit. Eng., ASCE, Vol.18, No.2, pp.148-154. https://doi.org/10.1061/(ASCE)AE.1943-5568.0000057
  3. Lawson, R.M. and Richards, J. (2010) Modular Design for Highrise Buildings, Proc. Inst Civ Eng Struct Build, Vol.163, No.SB3, pp.151-164. https://doi.org/10.1680/stbu.2010.163.3.151
  4. Annan, C.D., Youssef, M.A., and El-Naggar, M.H. (2009) Seismic over Strength in Braced Frames of Modular Steel Buildings, J. Earthquake Engrg., Vol.13, No.1, pp.1-21. https://doi.org/10.1080/13632460902813190
  5. Hong, S-G., Cho, B-H., Chung, K-S., and Moon, J-H. (2011) Behavior of Framed Modular Building System with Double Skin steel Panels, J. Construct Steel Res., Vol.67, pp.936-946. https://doi.org/10.1016/j.jcsr.2011.02.002
  6. 하태휴, 조봉호, 김태형, 이두용, 엄태성(2013) 내력벽식 스터드 패널을 적용한 모듈러건물유닛의 내진성능, 한국강구조학회논문집, 한국강구조학회, 제25권, 제5호, pp. 519-530.(Ha, T.H., Cho, B.H., Kim, T.H., Lee, D.Y., and Eom, T.S. (2013) Earthquake Resistance of Modular Building Units Using Load-Bearing Steel Stud Panels, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.5, pp.519-530 (in Korean).)
  7. 이상섭, 배규웅, 박금성, 홍성엽(2013) 유닛 모듈러 기둥-보 조인트의 구조성능에 대한 실험적 평가, 한국강구조학회논문집, 한국강구조학회, 제25권, 제3호, pp.255-265.(Lee, S.S., Bae, K.W., Park, K.S., and Hong, S.Y. (2013) An Experimental Evaluation of Structural Performance for the Beam to Column Joints in Unit Modular System, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.3, pp.255-265 (in Korean).) https://doi.org/10.7781/kjoss.2013.25.3.255
  8. 마향욱, 오현철, 김동욱, Kong Davon, 심창수(2012) 충전원형강관을 이용한 모듈러 교각의 휨 거동 평가, 한국강구조학회논문집, 한국강구조학회, 제24권, 제6호, pp.725-734.(Ma, H.W., Oh, H.C., Kim, D.W., Kong Davon., and Shim, C.S. (2012) Evaluation of Flexural Behavior of a Modular Pier with Circular CFT, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.6, pp.725-734 (in Korean).) https://doi.org/10.7781/kjoss.2012.24.6.725
  9. Lehman, D.E. and Roeder, C.W. (2012) Foundation Connections for Circular Concrete-Filled Tubes, J. Construct. Steel Res., Vol.78, pp.212-25. https://doi.org/10.1016/j.jcsr.2012.07.001
  10. Moon, J., Lehman, D.E., Roeder, C.W., and Lee, H-E. (2013) Evaluation of Embedded Concrete-Filled Tube (CFT) Column-to-Foundation Connections, Eng. Struct., Vol.56, pp.22-35. https://doi.org/10.1016/j.engstruct.2013.04.011
  11. ABAQUS (2009) ABAQUS Analysis User's Manual Version 6.9-2. Dassault Systemes Simulia Corp., Providence, RI, USA.
  12. Moon, J, Lehman, D.E., Roeder, C.W., and Lee, H-E. (2012) Analytical Modeling of Bending of Circular Concrete-Filled steel Tubes, Eng. Struct., Vol.42, pp.349-361. https://doi.org/10.1016/j.engstruct.2012.04.028
  13. Saenz, L.P. (1964) Discussion of 'Equation for the stress-strain curve of concrete' by P. Desayi, and S. Krishnan, ACI J., Vol.61, pp.1229-1235.
  14. Hsu, T.T.C. and Mo, Y-L. (2010) Unified Theory of Concrete Structures, 2nd edition, John Wiley & Sons, Inc.
  15. Lee, J. and Fenves, G.L. (1998) Plastic-Damage Model for Cyclic Loading of Concrete Structures, Journal of Engineering Mechanics, ASCE, Vol.124, No.8, pp.892-900. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:8(892)