DOI QR코드

DOI QR Code

Mobile Energy Shelter House(MeSH) for victims when a disaster occurs - Focused on Indoor Thermal Environmental Performance -

재난·재해 시 이재민을 위한 이동형 에너지 셜터하우스 (MeSH) 계획 -실내 온열환경 성능을 중심으로-

  • Shin, Hwayeon (Dept. of Architectural Engineering, Kyungpook National Univ.) ;
  • Kim, Jeonggook (Dept. of Architectural Engineering, Sungkyunkwan Univ.) ;
  • Kim, Jonghun (Building Energy Research Center, KIER) ;
  • Jeong, Hakgeun (Building Energy Research Center, KIER) ;
  • Jang, Cheolyong (Building Energy Research Center, KIER) ;
  • Hong, Wonhwa (Dept. School of Architecture&Civil Engineering, Kyungpook National Univ.)
  • Received : 2014.10.08
  • Accepted : 2014.12.15
  • Published : 2014.12.31

Abstract

Development of temporary housing for victims whose house damaged is required. In this study is to plan temporary house space 'Mobile Energy Shelter House ; MeSH' that can be inhabited for a long time. And measure the indoor Environmental performance. 'Mobile Energy Shelter House : MeSH' was made by reflecting Passive Design, Universal Design. Also, thermal insulation that meets the 'Korea standard insulation' for use low energy. Winter season, measuring temperature, humidity, air velocity and radiation temperature when floor heating that temperature controllers ware installed is used. Confirmed the data for the 8:00pm to 8:00am because evening hours are expected as residents live. Average outdoor temperature was $-11.3^{\circ}C$ and Indoor temperature was from $16.09^{\circ}C$ to $20.63^{\circ}C$. Calculated the TDRi of the window surface for checked condensation risk. TDRi value was 0.185. Furthermore, PMV value was -0.08 to -0.85. It was satisfied to ISO comfort criterion ranged.

Keywords

References

  1. Shin, Hwa-Yeon, Kim, Jong-Hun, Jeong, Hak-Geun, Jang, Cheol-Yong, Hong, Won-Hwa, A Study on Mobile Energy Shelter House for Emergency welfare, Conference Journal of Architectural Institute of Korea, 2013.10
  2. Shin, Hwa-Yeon, Kim, Jeong-Gook, Kim, Jong-Hun, Jeong, Hak-Geun, Jang, Cheol-Yong, Hong, Won-Hwa, Indoor Thermal Environmental Performance of Mobile Energy Shelter House for Emergency Welfare, Conference Journal of Society of Air-conditioning and Refrigerating Engineering Korea, 2014
  3. Kim, Min-Gyeong, Moon, Hyuk, Kim, Hye-jung, Kim, Kyung-Sook, A Study on the Residential Planning Factors for Emergency Shelter after Disaster, Journal of Architectural Institute of Korea, 2011.06
  4. Moon, Jung-In, Song, Yeong-Hak, Wang, Woo-Chul, Lim, Seok-Ho, A Study Field Examinations and Interviews for Yeonpyeongdo Temperary Housing, Journal of the Korean Housing Association, 2012
  5. Park, Yeon-JiK, A research of actual conditions of temporal residence in stricken districts, Journal of Residention Environment Institute of Korea, 2004.05
  6. Song, Yeong-Hak, Wang, Woo-Chul, Lim, Seok-Ho, A Study of Temperary housing Design with Unit Modular Method, Journal of Architectural Institute of Korea, 2013.03
  7. Choi, Gyeong-Seok, Sohn, Jang-Yeul, Thermal Performance Evaluation of Apartment Housing Using Infra-red Camera, Journal of Society of Air-conditioning and Refrigerating Engineering Korea, 2010
  8. Max H. Sherman, The Use of Blower Door Data, LBL Report No. 35173, 03, 1998
  9. Ministry of infrastructure and Transport, Standards for Preventing the condensation in Multi-Residential House, 2013-845, 2013
  10. Fanger, P. O., Thermal Comfort, Dnish Technical Press, Copenhagen, 1970
  11. ASHRAE, Thermal Environmental ANSI/ASHRAE Standard 55-2004, 2004
  12. ASHRAE, Handbook Fundamentals (SI) 2013
  13. ISO 7730, Ergonomics of the thermal environment 2005
  14. Nationnal Disaster Information Center, Disaster yearbook, 2002-2012
  15. Ministry of infrastructure and Transport, Minimum Housing Standards Revision 2011-490, 2011

Cited by

  1. 방재주택 계획을 위한 공간계획 컨셉 및 수법의 고찰 - 일본 민간주택회사의 주택상품을 중심으로 - vol.18, pp.3, 2014, https://doi.org/10.12813/kieae.2018.18.3.033