PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor

P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가

  • Received : 2013.12.14
  • Accepted : 2013.01.25
  • Published : 2014.01.30

Abstract

PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

PACS에서 용량이 큰 의료영상은 대용량 저장장치를 필요로 하고, 느린 전송으로 인하여 PACS의 성능을 저하시킨다. 따라서 판독의에 의해 판독되어진 영상이나 장기간 저장하는 영상의 질을 떨어뜨리지 않고, 추후 판독에 영향을 주지 않는 범위 내에서 압축하여 보관하게 된다. 압축 및 영상 저장 전송 시 발생되는 noise과 영상저장 및 전송 시 발생하는 정보손실 그리고 의료영상을 모니터에서 출력 시 발생하는 화질저하 등 많은 문제점 들이 발생한다. 본 연구는 P사 DSA 시스템의 Server display monitor와 Client display monitor의 PSNR을 평가하여 Server display 신호획득에서 부터 Client display monitor까지의 과정에서 발생하는 PSNR에 대한 평가 및 개선방안을 제안하고자 한다. 실험에 사용한 장비는 P사 DSA를 사용하였다. 혈관조영술 영상을 display하여 실험에 사용한 모니터로는 2가지로써 P사의 해상도 $1280{\times}1024$ 픽셀 모니터와 W사의 해상도 $1536{\times}2048$ 픽셀 모니터를 사용하였다. PACS Program은 MARO-view를 이용하였고 실험을 위해서 Visual $C^{++}$을 이용한 PSNR 측정 Program을 구현하여 실험에 사용하였다. 실험결과 No 1, 3번의 PSNR에 변화가 없는 것은 영상의 전송과 디스플레이 상에 Error가 없는 것으로 나타났으며, 압축률에서는 압축률이 낮은 쪽이 화질저하가 적었고, 영상의 손실 차이가 미미해 압축률에 따른 큰 문제점은 발견되지 않았다.

Keywords

References

  1. S.G. Hong, Y.J. Kim, "Using CR System at the Department of Radiation Oncology PACS Evaluation", J. Korean. Soc. Radiol., Vol. 6, No. 2, pp. 143-149, 2012. https://doi.org/10.7742/jksr.2012.6.2.143
  2. http://terms.naver.com/entry.nhn?docId=1214537&cid=40942&categ oryId=32746
  3. Cha S.J., Kim S.H., Kim Y.H., Hwang Y.J., Seo J.W., Kim S.Y., Kim M.Y., Kim H.R., Han Y.H., Hur G., Park J.H., Lee B.H., Lee S.T., Oh B.G., "Clinical Evaluation of the JPEG2000 Compression Rate of CT and MR Images for Long Term Archiving in PACS", J Korean Radiol Soc., Vol. 54, pp. 227-233, 2006. https://doi.org/10.3348/jkrs.2006.54.3.227
  4. K.S. Kang, "PSNR Appraisal of PACS Image", Nambu University, 2011.
  5. K.S. Kang, J.H. Lee, "PSNR Appraisal of MRI Image", Journal of the Korean Society of Radiology, Vol. 3, No. 4, pp. 13-20, 2009.
  6. K.J. Lee, M.G. Kim, J.W. Lee, H.C. Kim, "Research for The Environmental Optimization of Dose and Image quality in Digital Radiography", Journal of The Institute of Electronics Engineers of Korea, Vol. 50, NO. 2, pp. 203-209, 2013. https://doi.org/10.5573/ieek.2013.50.2.203
  7. J.W. Min, J.M. Kim, H.W. Jeong, C.O. "Research About Filter Association and Clinical Effect Noise Reduction of Digital Medical Imaging System", Journal of radiological science and technology, Vol. 30, No. 4, pp. 329-334, 2007.
  8. H.K. Jung, "Fundamentals of multimedia chapter 8, Lossy compression Algorithms", Hallym University, 2008.
  9. M.M. Sung, H.J. Kim, E.K. Kim, J.Y. Kwak, J.K. Yoo, H.S. Yoo, "Clinical Evaluation of JPEG2000 Compression Algorithm for Digital Mammography", Journal of the Korean society of imaging informatics in medicine, Vol. 7, pp. 13-19, 2001.
  10. The Korean Society of Medical Imaging Technology, "Textbook of Vascular And Interventional Radiography", CHUNG-KU Publisher, pp. 57, 2009.
  11. S.H. Park, J.J. Lee, G.S. Lee, G.Y. Kim, "Flexible Background - Texture Analysis for Coronary Artery Extraction Based on Digital Subtraction Angiography", Korea Information Processing Society Review, Vol. 12-B, No. 5, pp. 543-552, 2005. https://doi.org/10.3745/KIPSTB.2005.12B.5.543
  12. Korogi Y, Takahashi M, Katada K, et al., "Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering -comparison with conventional angiographic and surgical findings." Radiology, Vol. 211, pp .497-506, 1999. https://doi.org/10.1148/radiology.211.2.r99ma02497
  13. Anxionnat R, Bracard S, Ducrocq X, Trousset Y, et al., "Intracranial aneurysms: clinical value of 3D digital subtraction angiofraphy in the therapeutic decision and endovascular treatment", Radiology, Vol. 218, pp. 799-808, 2001. https://doi.org/10.1148/radiology.218.3.r01mr09799

Cited by

  1. Improvement of Angiogram Quality Using by High Pass Filter vol.8, pp.6, 2014, https://doi.org/10.7742/jksr.2014.8.6.301