Abstract

In general, sulfur containing odorants are added to fuel gases, such as LPG, and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. In this study, sulfur free odorant for low sulfur fuel and prevention of metal corrosion were developed to replace current sulfur containing odorant for gas fuel. They were selected from 12 odorant containing non-sulfur organic compounds and evaluated by odor olfactory method (odor quality, odor intensity). Finally, selected mixture odorants were methyl isovalerate, methyl acrylate, 2-ethyl-3-methyl pyrazine with blending ratio of 50% : 40% : 10%. Final Sulfur free odorant was added 40 wt ppm in LPG fuels and evaluated fuel quality characteristics, metal corrosion test and long term stability of LPG fuel. It were limit in current LPG fuel standard in fuel quality characteristics. Final Sulfur free odorant also had no influence on metal corrosion and long term stability test with 60 days by adding in LPG fuels. Finally, they were shown to be warning agent candidates to reduce sulfur content and metal corrosion for LPG fuel.

일반적으로 황분계 부취제는 연료가스로 인한 가스중독, 발화, 폭발 등의 사고를 방지하고, 배출가스에 의해 연료 가스 누출의 즉각적으로 손쉽게 검출할 수 있도록 LPG, 그리고 도시가스와 같은 연료가스에 첨가 사용하고 있다. 본 연구에서는 기존의 황을 함유한 가스용 부취제를 대체하여 연료의 저황분화와 금속 부식성을 낮출 수 있는 LPG 연료용 비황분계 부취제 개발을 위하여 실험하였다. 비황분계 부취제는 황을 함유하지 않는 12개의 부취물질을 선정하였으며, 직접 관능법에 의한 취질과 취기 평가를 실험하였다. 최종 선정된 혼합 부취물질은 methyl isovalerate, methyl acrylate, 2-ethyl-3-methyl pyrazine이며, 이때 조성비는 50% : 40% : 10% 이다. 최종 비황분계 부취제(K-Petro S-Free)는 LPG 연료에 40 wt ppm 혼합하여 품질평가, 금속 부식성 평가 그리고 장기 안정성 평가를 실험하였다. 이 때 LPG 연료용 비황분계 부취제는 국내 LPG 연료의 품질기준을 모두 만족하였다. 또한 금속에 대한 부식성에는 영향이 없으며, 60일간의 장기 안정성 평가에서 LPG연료의 조성에 영향을 주지 않았다. 따라서 최종 선정된 비황분계 부취제(K-Petro S-Free)는 LPG 연료의 첨가제로서 가능성을 보여주고 있다.

Keywords

References

  1. Therese, S., Elena, L., "Overcoming barriers to the implementation of alternative fuels for road transport in Europe", Journal of Cleaner Production, 16, 577-590, (2008) https://doi.org/10.1016/j.jclepro.2006.12.001
  2. Fuel quality standard of LPG in Korea, Korea Petroleum Quality & Distribution Authority, http://www.kpetro.or.kr/sub.jsp?MenuID=m2as402
  3. Arthur, R. K and Arun, V., "Measurement of Odorant Levels in Natural Gas", Ind. Eng. Chem., Prod. Res. Dev., 15(1), 59-63, (1976) https://doi.org/10.1021/i360057a011
  4. Marvin, L. W., John, W. G., Faye, O. C and Dennis, W. B., "Odorant Evaluation : A Study Ethanthiol and Tetrahydrothiophene as Waring agents in Propane", Environmental Science & Technology, 12(12), 1285-1288, (1978) https://doi.org/10.1021/es60147a003
  5. De wild, J. D., Nyqvist, R. G., De Bruiji F. A and Stobbe, E. R., "Removal of sulphur-containing odorants from fuel gases for fuel cellbased combined heat and power applications", Journal of Power Sources, 159, 995-1004, (2006) https://doi.org/10.1016/j.jpowsour.2005.11.100
  6. Lee, S. H., Song, T. Y., Baek, Y. S., "Optimization of Odor Concentration by Operation of Small Station Odorizer", KIGAS, 5(3), 36-44, (2001)
  7. Frank, G., Kerstin, K and Rainer, R., "Sulfur-Free Odorization with Gasodor S-Free-a Aeview of the Accompanying Research and Development Activities", Energy & Fules, 21, 3322-3333, (2007) https://doi.org/10.1021/ef700406x
  8. Imamura, D., Akai, M and Watanabe, S., "Exploration of Hydrogen Odorants for Fuel Cell Vehicles", Journal of Power Sources, 152, 226-232, (2005) https://doi.org/10.1016/j.jpowsour.2005.01.007
  9. Cui, H., Tum, S. Q and Reese, M. A., "Removal of sulfur compounds form utility pipelined synthetic natural gas using modified activated carbons", Catalysis Today, 139, 274-279, (2009) https://doi.org/10.1016/j.cattod.2008.03.024
  10. Ruzsanyi, V., Sielemann, S and Baumbach, J. I., "Detection of sulfur-free odorants in natural gas using ion mobility spectrometry", Journal of Environmental Monitoring, 9, 61-65, (2007) https://doi.org/10.1039/B613951E