References
- Yoon, G., Lee, J. Y., Jeon, K. J., et all, "Development of a compact home health monitor for telemedicine", Telemed. J. E. Health, Vol. 11, Issue6, pp. 660-667, January, 2005. https://doi.org/10.1089/tmj.2005.11.660
- M. Folke, L. Cernerud, M. Ekstrom, B. Hok, "Critical review of non-invasive respiratory monitoring in medical care", Medical & Biological Engineering & Computing, Vol. 41, Issue 4, pp.377-383, July, 2003. https://doi.org/10.1007/BF02348078
- J. Muhlsteff, O. Such, R. Schmidt, M. Perkuhn, H. Reiter, et al, "Wearable approach for continuous ECG and activity patient-monitoring", Engineering in Medicine and Biology Society, 26th Annual International Conference of the IEEE, Volume 1, Issue 1-5, pp. 2184 - 2187, Sept. 2004.
- Wan-Young Chung, S. Bhardwaj, A. Purwar, Dae-Seok Lee, R. Myllylae, "A Fusion Health Monitoring Using ECG and Accelerometer sensors for Elderly Persons at Home", Proceeding of Engineering in Medicine and Biology Society, 29th Annual International Conference of the IEEE, Issue 22-26, pp. 3818- 3821, Aug, 2007.
- Ram, M.R., Madhav, K,V., Krishna ,E.H., "A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter", IEEE Transactions on Instrumentation and Measurement, Vol. 61, Issue 5, pp. 1445-1457, May, 2012. https://doi.org/10.1109/TIM.2011.2175832
- Boreom Lee, Jonghee Han, Hyun Jae Baek, Jae Hyuk Shin, Kwang Suk Park, Won Jin Yi, "Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry", Physiological Measurement, Vol. 31, No. 12, pp.1585-1603, October, 2010. https://doi.org/10.1088/0967-3334/31/12/003
- Han-Wook Lee, Ju-Won Lee, Won-Geun Jung, and Gun-Ki Lee, "The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals", International Journal of Control, Automation, and Systems, vol. 5, no. 6, pp. 701-706, December, 2007.
- I. Brown and A. A. Adams, "The ethical challenges of ubiquitous healthcare", International Review of Information Ethics, Vol. 8, No. 12, pp. 53-60, 2007.
- J. W. Lee, W. G. Jung, G. K. Lee, et all, "Design of filter to reject motion artifact of pulse oximetry", Computer Standards & Interfaces, Vol. 26, Issue 3, pp. 241-249, May, 2004. https://doi.org/10.1016/S0920-5489(03)00077-1
- Ju-Won Lee, Jae-Hyun Nam, "Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors", J. lnf. Commun. Converg. Eng. Vol. 10, No. 1, pp. 91-95, Mar. 2012.
- Simon O. Haykin, "Adaptive Filter Theory", Prentice Hall, pp. 365-372, 2002.
- Daniel Barolet, "Light-Emitting Diodes (LEDs) in Dermatology", Seminars In Cutaneous Medicine and Surgery, Vol. 27, No. 4, pp. 227-238, Dec., 2008.