DOI QR코드

DOI QR Code

A Study on Design of 50kW PMSG for Micro-grid Application

마이크로그리드용 50kW급 PMSG 설계에 관한 연구

  • 정문선 (국립목포대학교 전기공학과) ;
  • 문채주 (국립목포대학교 스마트그리드연구소) ;
  • 김형길 ((주)설텍) ;
  • 장영학 (국립목포대학교 스마트그리드연구소) ;
  • 박태식 (국립목포대학교 스마트그리드연구소)
  • Received : 2014.01.27
  • Accepted : 2014.04.11
  • Published : 2014.04.30

Abstract

In this paper, the 50kW aerogenerator which is applicable to the microgrid was designed and analyzed by using commercial simulation program Maxwell 2D. Particularly, the suggested PMSG to reduce the cogging torque introduced the offset and skew concept. The suggested optimal value of offset and skew was decided by 2mm and 60 degree of electric angle. The simulation results of the PMSG when load operation condition showed the average harmonic distortion 1.3%, voltage 322.41V, current 94.95A, and iron loss 9.73W, eddy current loss 73.68W, copper loss 3.52kW. The capacity of aerogenerator calculated 61.56kW, and the suggested design process can be applied to higher capacity generator.

본 논문에서는 마이크로그리드 적용을 위한 50kW 풍력발전기를 설계하였으며, 발전기의 해석은 maxwell 2D 상용프로그램을 사용하였다. 특히 제안된 PMSG는 코깅토크를 줄이고자 offset과 skew를 적용하였다. 최적의 옵셋과 스큐는 2mm와 전기각 60도를 제안하였다. 부하운전시 모의결과는 평균 고조파 1.3%, 전압 322.41V, 전류 94.95A, 철손 9.73W, 와류손 73.68W, 동손 3.52kW로 나타났다. 계산된 발전기 용량은 61.56kW이며, 제안된 설계절차는 더 큰 용량의 발전기설계에 적용할 수 있다.

Keywords

References

  1. J. Park, "Small Wind," Kisti market report, vol. 2, Issue 7, 2012, pp. 3-7.
  2. S. Yang, J. Kwon, and W. Kim, "The Design of Operating System on Wind Power Plant," J. of the Korea Institute of Electronic Communication Sciences, vol. 6, no. 1, 2011, pp. 136-141.
  3. J.-K. Park and Y.-C. Bae, "Development of a Technical Road Map for Future Research in Wind Power Generation using Grading Criteria as a Rubric for Research Focus," J. of the Institute of Electronic Communication Sciences, vol. 6, no. 3, 2011, pp. 417-423.
  4. Y.-K. Jeong, T.-H. Um, G.-H. Kim, and W. Hun, "A hybrid study on self-generators based on system for high-efficiency," J. of the Korea Institute of Electronic Communication Sciences, vol. 6, no. 6, 2011, pp. 897- 902.
  5. J. Lee, G. Kwon, B. Han, and H. Cha, "Operational Characteristic Analysis of DC Micro-grid with Detail Model of Distributed Generation," The Trans. of the Korean Institute of Electrical Engineers, vol. 58, no. 11, 2009, pp. 2175-2184.
  6. H. Li, Z. Chen, and H. Polinder, "Optimization of Multibrid Permanent-Magnet Wind Generator Systems," IEEE Trans. Energy Conversion, vol. 24, no. 1, 2009, pp. 82-92. https://doi.org/10.1109/TEC.2008.2005279
  7. S. Hauang and J. Luo, "A General Approach to Sizing and Power Density Equations For Comparison of Electrical Machines," IEEE Trans. Industry Applications, vol. 34, no. 1, 1998, pp. 92-97. https://doi.org/10.1109/28.658727
  8. T. Kim, "Design of 3MW Class Outer Rotor Type PMSG for Wind Turbine," J. of The korean society for new and renewable energy, vol. 6, no. 4, 2010, pp. 41-49.
  9. S. Lee, "Design and Comparison between 2MW Class RFPM and AFPM for Wind Turbine," Master's Thesis, Pohang Univ. of Science and Technology, 2012, pp. 54-55.
  10. J. Lee, S. Rhyu, Y. Kim, and I. Jung, "A Design for Improvement of Back-EMF performance in IPMSM Using of Electric Vehicles," Korean Society of Automotive Engineers Annual Conference, 2011, pp. 2355-2357.
  11. S. Kim, E. Kim, and J. Huh, "Voltage Quality and Network Interconnection Standard Suitability in Jeju-Hangwon Wind Power Generation Farm," J. of the Korean Solar Energy Society, vol. 26, no. 2, 2006, pp. 53-59.