There have distinctly been no the installation criteria and maintenance management of BIPV systems, although the BIPV market is consistently going on increasing. In addition, consideration of the BIPV generation quantity which has been installed at several diverse places is currently almost behind within region in Korea. Therefore, the main aim of this study is to evaluate the BIPV generation and to be base data of reducing rate depending on regional installation angles using PVpro which was verified by measured data. Various conditions were an angle of inclination and azimuth under six major cities: Seoul, Daejeon, Daegu, Busan, Gwangju, Jeju-si for the BIPV system generation analysis. As the results, Seoul showed the lowest BIPV generation: 1,054kWh/kWp.year, and Jeju-si have 5percent more generation: 1,108.0kWh/kWp.year than Seoul on horizontal plane. Gwangju and Daejeon turned out to have similar generation of result, and Busan showed the highest generation: 1,193.5kWh/kWp.year, which was increased by over 13percent from Seoul on horizontal plane. Another result, decreasing rate of BIPV generation depending on regional included angle indicate that the best position was located on azimuth: $0^{\circ}$(The south side) following the horizontal position(an angle of inclination: $30^{\circ}$). And the direction on a south vertical position(azimuth: $0^{\circ}$, an angle of inclination: $90^{\circ}$) then turned out reducing rate about 40percent compared with the best one. Therefore, these results would be used to identify the installation angle of the BIPV module as an appropriate position.

Keywords

References

  1. Solar & Energy, arket trend and perspectives of the world BIPV(2009-2020) 2nd version, pp. 348, June. 2012
  2. Energy Economic News, http://www.ekn.kr/news/articleView.html?idxno=78262, 2012
  3. Song, Jong-Hwa et al, "Power Performance Characteristics of Transparent Thin-film BIPV Module depending on an installation angle", Journal of Korean Solar Energy Society Vol.28 No2, pp 58-63, 2008
  4. Ju, Jai-Wook et al, "A Study on the Difference of Regional Electricity and Economic Comparative Valuation of the Photovoltaic System" Korean Institute of Architectural Sustainable Enviroment and Building Systems, Presentation paper, 2008
  5. Lee, Jaydy, Kim, Chul-Hwan, "An Analysis of Optimal Installation Condition and Maximum Power Generation of Photovoltaic Systems Applying Perez Model", The Transactions of the Korean Institute of Electrical Engineers Vol. 61, No. 5, pp. 683-689, 2012 https://doi.org/10.5370/KIEE.2012.61.5.683
  6. Yoon, Jong-Ho et al, "Software Development on Power and Economic Analysis of Photovoltaic System for Building Application", Journal of Korean Solar Energy Society Vol. 28, No. 1, pp. 1-8, 2008
  7. Yoon, Jonh-Ho et al, "Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level", Journal of Korean Solar Energy Society Vol. 32, No. 4, pp. 24-33, 2012 https://doi.org/10.7836/kses.2012.32.4.024
  8. TRNSYS Version 14.2 Manual, Solar Energy Laboratory Univerversity of Wisconsin-Madison, WI 53706 USA, 2000
  9. http://www.kma.go.kr/weather/observation/currentweather

Cited by

  1. An Experimental Study on the Performance Evaluation of Building Integrated Photovoltaic (BIPV) Generated Curtain-Wall for Reliability Verification vol.19, pp.2, 2014, https://doi.org/10.12813/kieae.2019.19.2.065
  2. 태양광발전시스템 국내 지역별 발전특성 분석 vol.39, pp.2, 2014, https://doi.org/10.7836/kses.2019.39.2.033