DOI QR코드

DOI QR Code

Frequency Control of in Hybrid Wind Power System using Flywheel Energy Storage System

  • Lee, Jeong-Phil (Dept. of New & Renewable Electric Energy, Kyungnam College of Information & Technology) ;
  • Kim, Han-Guen (Dept. of New & Renewable Electric Energy, Kyungnam College of Information & Technology)
  • Received : 2014.08.10
  • Published : 2014.06.01

Abstract

In this paper, a design problem of the flywheel energy storage system controller using genetic algorithm (GA) is investigated for a frequency control of the wind diesel hybrid power generation system in an isolated power system. In order to select parameters of the FESS controller, two performance indexes are used. We evaluated a frequency control effect for the wind diesel hybrid power system according to change of the weighted values of a performance index. To verify performance of the FESS controller according to the weighted value of the performance index, the frequency domain analysis using a singular value bode diagram and the dynamic simulations for various weighted values of performance index were performed. To verify control performance of the designed FESS controller, the eigenvalue analysis and the dynamic simulations were performed. The control characteristics with the two designed FESS controller were compared with that of the conventional pitch controller. The simulation results showed that the FESS controller provided better dynamic responses in comparison with the conventional controller.

Keywords

References

  1. S. C. Tripathy, M. Kalantar, and R. Balasubramanian, "Dynamics and stability of wind and diesel turbine generators with superconducting magnetic energy strorage unit on an isolated power system," IEEE Trans. On Energy Conversion, vol. 6, no. 4, pp. 579-585, Dec., 1991 https://doi.org/10.1109/60.103628
  2. S. C. Tripathy and I. P. Mishra, "Dynamic performance of wind-diesel power system with capacitiver energy storage," Energy Convers. Mgmt, vol. 37, no. 12, pp. 1787-1798l, 1996 https://doi.org/10.1016/0196-8904(96)00026-X
  3. S. C. Tripathy, "Dynamic simulation of hybrid winddiesel power generation system with superconductor magnetic energy storage," Energy Convers. Mgmt, vol. 38, no. 9, pp. 919-930, 1997 https://doi.org/10.1016/S0196-8904(96)00093-3
  4. T. S. Bhatti, A. A. AL-Ademi and N. K. Bansal, "Load frequency control of isolated wind diesel hybrid power system," Energy convers. Mgmt, vol. 38, no. 9, pp. 829-837, 1997 https://doi.org/10.1016/S0196-8904(96)00108-2
  5. D. Das, S. K. Aditya, and D. P. Kothari, "Dynamics of diesel and wind turbine generator on an isolated power system," Electrical power and energy system, 21, pp. 193-189, 1999
  6. V. P. Singh, S. R. Mohanty, N. Kishor, and P. K. Ray, "Robust H-infinity load frequency control in hybrid distributed generation system," Electrical power and energy systems, 46, pp. 294,305, 2013