DOI QR코드

DOI QR Code

Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

  • Seo, Jae-Min (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science and Research Institute of Clinical Medicine, Chonbuk National University) ;
  • Ahn, Seung-Geun (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science and Research Institute of Clinical Medicine, Chonbuk National University)
  • Received : 2013.09.30
  • Accepted : 2014.01.14
  • Published : 2014.06.30

Abstract

Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

Keywords

References

  1. Yoon TH, Chang WG. The fabrication of a CAD/CAM ceramic crown to fit an existing partial removable dental prosthesis: a clinical report. J Prosthet Dent 2012;108:143-6. https://doi.org/10.1016/S0022-3913(12)60137-1
  2. Burt D. Copy existing tooth form to retrofit to an RPD accurately: an ideal CAD/CAM application. Dent Today 2009; 28:140-1.
  3. Helvey GA. Retrofitting crowns to an existing removable partial denture clasp: a simple technique. J Prosthet Dent 2002;87:399-402. https://doi.org/10.1067/mpr.2002.122867
  4. Livaditis GJ. Fabricating abutment crowns for existing removable partial dentures using custom resin clasp analogs. J Prosthet Dent 1998;80:619-29. https://doi.org/10.1016/S0022-3913(98)70041-1
  5. Tran CD, Sherraden DR, Curtis TA. A review of techniques of crown fabrication for existing removable partial dentures. J Prosthet Dent 1986;55:671-3. https://doi.org/10.1016/0022-3913(86)90439-7
  6. Hill GM. Construction of a crown to fit a removable partial denture clasp. J Prosthet Dent 1977;38:226-8. https://doi.org/10.1016/0022-3913(77)90290-6
  7. Macpherson JR, Evans DB. Fabricating crowns to fit existing removable partial dentures: an illustration of two techniques. J Prosthodont 1993;2:199-205. https://doi.org/10.1111/j.1532-849X.1993.tb00408.x
  8. Silberman DM. An indirect procedure for making a crown under an existing partial denture. J Prosthet Dent 1993;69: 631-3. https://doi.org/10.1016/0022-3913(93)90296-Z
  9. Schneider RL. Adapting ceramometal restorations to existing removable partial dentures. J Prosthet Dent 1983;49:279-81. https://doi.org/10.1016/0022-3913(83)90516-4
  10. Raskin ER. An indirect technique for fabricating a crown under an existing clasp. J Prosthet Dent 1983;50:580-1. https://doi.org/10.1016/0022-3913(83)90585-1
  11. Fahmy NZ, Salah E. An in vitro assessment of a ceramicpressed- to-metal system as an alternative to conventional metal ceramic systems. J Prosthodont 2011;20:621-7. https://doi.org/10.1111/j.1532-849X.2011.00767.x
  12. Goldin EB, Boyd NW 3rd, Goldstein GR, Hittelman EL, Thompson VP. Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations. J Prosthet Dent 2005;93:143-7. https://doi.org/10.1016/j.prosdent.2004.10.023
  13. Venkatachalam B, Goldstein GR, Pines MS, Hittelman EL. Ceramic pressed to metal versus feldspathic porcelain fused to metal: a comparative study of bond strength. Int J Prosthodont 2009;22:94-100.

Cited by

  1. Fabricating a Ceramic-Pressed-to-Metal Restoration with Computer-Aided Design, Computer-Aided Manufacturing and Selective Laser Sintering: A Case Report vol.8, pp.1, 2015, https://doi.org/10.5856/JKDS.2015.8.1.41
  2. Digital Workflow for Retrofitting a Surveyed Crown Using a Removable Partial Denture as an Antagonist vol.29, pp.6, 2014, https://doi.org/10.1111/jopr.13187