DOI QR코드

DOI QR Code

Stereotactic Vacuum-Assisted Core Biopsy Results for Non-Palpable Breast Lesions

  • Agacayak, Filiz (Department of Radiology, Istanbul Florence Nightingale Hospital) ;
  • Ozturk, Alper (Department of Breast Surgery, Istanbul Florence Nightingale Hospital) ;
  • Bozdogan, Atilla (Department of Biostatistics, Istanbul Florence Nightingale Hospital) ;
  • Selamoglu, Derya (Department of Breast Surgery, Istanbul Florence Nightingale Hospital) ;
  • Alco, Gul (Department of Radiation Oncology, Gayrettepe Florence Nightingale Hospital) ;
  • Ordu, Cetin (Department of Medical Oncology, Faculty of Medicine, Istanbul Bilim University) ;
  • Pilanci, Kezban Nur (Department of Medical Oncology, Faculty of Medicine, Istanbul Bilim University) ;
  • Killi, Refik (Department of Radiology, Istanbul Florence Nightingale Hospital) ;
  • Ozmen, Vahit (Department of Breast Surgery, Istanbul Florence Nightingale Hospital)
  • Published : 2014.07.15

Abstract

Background: The increase in breast cancer awareness and widespread use of mammographic screening has led to an increased detection of (non-palpable) breast cancers that cannot be discovered through physical examination. One of the methods used in the diagnosis of these cancers is vacuum-assisted core biopsy, which prevents a considerable number of patients from undergoing surgical procedures. The aim of this study was to present the results of stereotactic vacuum-assisted core biopsy for suspicious breast lesions. Materials and Methods: Files were retrospectively scanned and data on demographic, radiological and pathological findings were recorded for patients who underwent stereotactic vacuum-assisted core biopsy due to suspicious mammographic findings at the Interventional Radiology Centre of the Florence Nightingale Hospital between January 2010, and April 2013. Statistical analysis was carried out using Pearson's Chi-square, continuity correction, and Fisher's exact tests. Results: The mean age of the patients was 47 years (range: 36-70). Biopsies were performed due to BIRADS 3 lesions in 8 patients, BIRADS 4 lesions in 77 patients, and BIRADS 5 lesions in 3 patients. Mammography elucidated clusters of microcalcifications in 73 patients (83%) and focal lesions (asymmetrical density, distortion) in 15 patients (17%). In terms of complications, 1 patient had a hematoma, and 2 patients had ecchymoses (3/88; 3.3%). The histopathologic results revealed benign lesions in 63 patients (71.6%) and malignant lesions in 25 patients (28.4%). The mean duration of the procedure was 37 minutes (range: 18-55). Although all of the BIRADS 3 lesions were benign, 22 (28.6%) of the BIRADS 4 lesions and all of the BIRADS 5 lesions were malignant. Among the malignant cases, 80% were in situ, and 20% were invasive carcinomas. These patients underwent surgery. Conclusions: In cases where non-palpable breast lesions are considered to be suspicious in mammography scans, the vacuum-assisted core biopsy method provides an accurate histopathologic diagnosis thus preventing a significant number of patients undergoing unnecessary surgical procedures.

Keywords

References

  1. Ames V, Britton PD (2011). Stereotactically guided breast biopsy: a review. Insights Imaging, 2, 171-6. https://doi.org/10.1007/s13244-010-0064-1
  2. Avci IA, Kumcagiz H, Altinel B, Caloglu A (2014). Turkish female academician self-esteem and health beliefs for breast cancer screening. Asian Pac J Cancer Prev, 15, 155-60. https://doi.org/10.7314/APJCP.2014.15.1.155
  3. Brenner RJ, Bassett LW, Fajardo LL, et al (2001). Stereotactic core-needle breast biopsy: a multi-institutional prospective trial. Radiology, 218, 866-72. https://doi.org/10.1148/radiology.218.3.r01mr44866
  4. Burbank F, Parker SH, Fogarty TJ (1996). Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg, 62, 738-44.
  5. Ciatto S, Houssami N, Ambrogetti D, et al (2007). Accuracy and underestimation of malignancy of breast core needle biopsy: the Florence experience of over 4000 consecutive biopsies. Breast Cancer Res Treat, 101, 291-97. https://doi.org/10.1007/s10549-006-9289-6
  6. Dogan L, Gulcelik MA, Yuksel M, Uyar O, Reis E (2012). Wire-guided localization biopsy to determine surgical margin status in patients with non-palpable suspicious breast lesions. Asian Pac J Cancer Prev, 13, 4989-92. https://doi.org/10.7314/APJCP.2012.13.10.4989
  7. Domeyer PJ, Sergentanis TN, Katsari V, et al (2013). Screening in the era of economic crisis: Misperceptions and misuse from a longitudinal study on Greek women undergoing benign vacuum-assisted breast biopsy. Asian Pac J Cancer Prev, 14, 5023-9. https://doi.org/10.7314/APJCP.2013.14.9.5023
  8. Faour I, Al-Salam S, El-Terifi H, El Taji H (2008). The use of a vacuum-assisted biopsy device (Mammotome) in the early detection of breast cancer in the United Arab Emirates. Ann N Y Acad Sci, 1138, 108-13. https://doi.org/10.1196/annals.1414.016
  9. Fouladi N, Pourfarzi F, Mazaheri E, et al (2013). Beliefs and behaviors of breast cancer screening in women referring to health care centers in northwest Iran according to the Champion health belief model scale. Asian Pac J Cancer Prev, 14, 6857-62. https://doi.org/10.7314/APJCP.2013.14.11.6857
  10. Huang M, Adrada BE, Candelaria R, et al (2014). Stereotactic breast biopsy: pitfalls and pearls. Tech Vasc Interv Radiol, 17, 32-9. https://doi.org/10.1053/j.tvir.2013.12.006
  11. Jackman RJ, Marzoni FA Jr, Rosenberg J (2009). False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1,280 lesions and review of the literature. AJR Am J Roentgenol, 192, 341-51. https://doi.org/10.2214/AJR.08.1127
  12. Kettritz U, Rotter K, Schreer I, et al (2004). Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study. Cancer, 100, 245-51. https://doi.org/10.1002/cncr.11887
  13. Kumaroswamy V, Liston J, Shaaban AM (2008). Vacuum assisted stereotactic guided mammotome biopsies in the management of screen detected microcalcifications: experience of a large breast screening centre. J Clin Pathol, 61, 766-9.
  14. Lee KE, Kim HH, Shin HJ, Cha JH (2013). Stereotactic biopsy of the breast using a decubitus table: comparison of histologic underestimation rates between 11- and 8- gauge vacuum-assisted breast biopsy. Springerplus, 2, 551. https://doi.org/10.1186/2193-1801-2-551
  15. Liberman L, Abramson AF, Squires FB, et al (1998). The breast imaging reporting and data system: positive predictive value of mammographic features and final assessment categories. Am J Roentgenol, 171, 35-40. https://doi.org/10.2214/ajr.171.1.9648759
  16. Liberman L, Vuolo M, Dershaw DD, et al (1999). Epithelial displacement after stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol, 172, 677-81. https://doi.org/10.2214/ajr.172.3.10063859
  17. Mendez A, Cabanillas F, Echenique M, et al (2004). Mammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB). Ann Oncol, 14, 450-4.
  18. Meyer JE, Smith DN, Lester SC, et al (1999). Large-core needle biopsy of nonpalpable breast lesions. JAMA, 281, 1638-41. https://doi.org/10.1001/jama.281.17.1638
  19. NHS Breast Screening Programme (2009) NHS breast screening programme review ISBN 978 1 84463 064 6. www.cancerscreening.nhs.uk//breastscreen/publications/2009review.html
  20. NHS Breast Screening Programme and Association of Breast Surgery at BASO (2010) An audit of screen-detected breast cancers for the year of screening April 2008 to March 2009.
  21. Perry N, Broeders M, de Wolf C, et al (2006). European guidelines for quality assurance in breast cancer screening and diagnosis, 4th edn, ISBN 92-79-01258-4.
  22. Philpotts LE, Lee CH, Horvath LJ, Tocino I (1997) Canceled stereotactic core-needle biopsy of the breast: analysis of 89 cases, Radiology, 205, 423-8. https://doi.org/10.1148/radiology.205.2.9356623
  23. Rotter K, Haentschel G, Koethe D, et al (2003). Evaluation of mammographic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies. Am J Surg, 186, 134-42. https://doi.org/10.1016/S0002-9610(03)00176-4
  24. Shah VI, Raju U, Chitale D, et al (2003). False-negative core needle biopsies of the breast: an analysis of clinic, radiologic, and pathologic findings in 27 consecutive cases of missed breast cancer. Cancer, 97, 1824-31. https://doi.org/10.1002/cncr.11278
  25. Tate PS, Rogers EL, McGee EM, et al (2001). Stereotactic breast biopsy: a six year surgical experience. J Ky Med Assoc, 99, 98-103.
  26. Tonegutti M, Girardi V (2008). Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions. Radiol Med, 113, 65-75. https://doi.org/10.1007/s11547-008-0226-0
  27. Tothova L, Rauova K, Valkovic L, Vanovcanova L, Lehotska V (2013). Stereotactic vacuum-assisted breast biopsy: our experience and comparison with stereotactic automated needle biopsy. Bratisl Lek Listy, 114, 71-7.
  28. Uyeturk U, Tatli AM, Gucuk S, et al (2013). Risk factors for stage IV breast cancer at the time of presentation in Turkey. Asian Pac J Cancer Prev, 14, 7445-49. https://doi.org/10.7314/APJCP.2013.14.12.7445
  29. Wang XW, Xiong YH, Zen XQ, Lin HB, Liu QY. (2012). Diagnostic accuracy of ultrasonography guided fine-needle aspiration cytologic in staging of axillary lymph node metastasis in breast cancer patients: a meta-analysis. Asian Pac J Cancer Prev, 13, 5517-23. https://doi.org/10.7314/APJCP.2012.13.11.5517

Cited by

  1. Comparison between Radiological and Invasive Diagnostic Modalities in Diagnosis of Breast Cancer vol.16, pp.10, 2015, https://doi.org/10.7314/APJCP.2015.16.10.4323
  2. Image-guided vacuum-assisted breast biopsy in the diagnosis of breast microcalcifications vol.46, pp.7, 2018, https://doi.org/10.1177/0300060518770577