DOI QR코드

DOI QR Code

Phase Resonance in Centrifugal Fluid Machinery -A Comparison between Pump Mode and Turbine Mode Operations and a Discussion of Mechanisms of Flow Rate Fluctuation through a Stator-

  • 투고 : 2014.02.24
  • 심사 : 2014.03.18
  • 발행 : 2014.06.30

초록

Phase resonance in Francis type hydraulic turbine is studied. The phase resonance is a phenomenon that the pressure fluctuation in the penstock of hydraulic turbine installation can become very large when the pressure waves from each guide vane caused by the interaction with the runner vane reach the penstock with the same phase. Experimental and numerical studies have been carried out using a centrifugal fan. In the present study, comparisons between the pump mode and the turbine mode operations are made. The experimental and numerical results show that the rotational direction of the rotor does not affect characteristics of the pressure fluctuation but the propagation direction of the rotorstator interaction mode plays an important role. Flow rate fluctuations through the stator are examined numerically. It has been found that the blade passing flow rate fluctuation component can be evaluated by the difference of the fluctuating pressure at the inlet and the outlet of the stator. The amplitude of the blade passage component of the pressure fluctuation is greater at the stator inlet than the one at the stator outlet. The rotor-stator interaction mode component is almost identical at the inlet and the outlet of the stator. It was demonstrated that the pressure fluctuation in the volute and connecting pipe normalized by the flow rate fluctuation becomes the same for pump and turbine mode operations, and depends on the rotational direction on the interaction mode.

키워드

참고문헌

  1. Den Hartog J.P., 1929, "Mechanical Vibrations in Penstocks of Hydraulic Turbine Installations," Transactions of ASME.
  2. Y.N. Chen, 1961, "Wasserdruckschwingungen in Spiralgeh a usen von Speicherpumpen," Suzer-Forschungsheft.
  3. P. Doerfler, 1984, "On the role of phase resonance in vibrations caused by blade passage in radial hydraulic turbomachines," proceedings of IAHR SYMPOSIUM.
  4. Y. Ohura, M. Fujii, O. Sugimoto, H. Tanaka, I. Yamamoto, 1990, "Vibration of the powerhouse structure of a pumped storage power plant," proceedings of IAHR SYMPOSIUM.
  5. Nishiyama, Y., Suzuki, T., Yonezawa, K., Tanaka, H., Doerfler, P., and Tsujimoto, Y., "Phase Resonance in a Centrifugal Compressor," International Journal of Fluid Machinery and Systems, Vol.4, No.3,July-September, 2011, pp. 325-333
  6. Tsujimoto, Y., Tanaka, H., Doerfler, P., Yonezawa, K., Suzuki, T., and Makikawa, K., Effects of Acoustic Resonance and Volute Geometry on Phase Resonance in a Centrifugal Fan, to be published in IJFMS.
  7. Makey, E., Cooper, P., Sloteman, D.P., Gibson, R., 1993, "Investigation of Pressure Pulsations Arising from Impeller/Diffuser Interaction in a Large Centrifugal Pump," Rotating Machinery: Problems & Solutions.
  8. Parmakian, J., Vibration of the Grand Coulee Pump-Discharge Lines, Trans. ASME, July 1954.
  9. T.J. Poinsot, and S.K. Lele, 1992, "Boundary Condition for Direct Simulations of Compressible Viscous Flows," Journal of Computational Physics 101, 104-129. https://doi.org/10.1016/0021-9991(92)90046-2

피인용 문헌

  1. Transient Pressure Analysis of a Prototype Pump Turbine: Field Tests and Simulation vol.140, pp.7, 2018, https://doi.org/10.1115/1.4039258