Evaluation of Fire Resistance of Unprotected Concrete-filled Rectangular Steel Tubular Columns under Axial Loading

재하가열시험에 의한 무내화피복 콘크리트충전 각형강관기둥의 내화성능평가

  • Ahn, Jae Kwon (Department of Architecture and Architectural Engineering, Seoul National University) ;
  • Lee, Cheol Ho (Department of Architecture and Architectural Engineering, Seoul National University)
  • Received : 2013.09.10
  • Accepted : 2014.07.15
  • Published : 2014.08.27

Abstract

In this paper, experimental program and associated numerical study were carried out to evaluate the fire resistance of unprotected concrete-filled rectangular steel tubular (CFT) columns subjected to the standard fire. The key testing parameters included the length effect, the load ratio, and the sectional dimensions of the CFT columns. Temperature distribution and axial deformation of the CFT column specimens were measured and analyzed. Rather early local buckling of steel tubes was observed in all the specimens. This caused subsequent load transfer from steel tube to concrete, and eventually triggered concrete crushing, or complete loss of the load bearing capacity of the column. This implies that the limit state of local buckling as well as overall flexural buckling should be incorporated in fire design procedure. As expected, the fire resistance time of specimen with higher load ratio consistently lessened. The prediction of fire resistance time of unprotected CFT columns based on the limiting steel temperature in current design codes or the formula proposed by previous studies is slightly conservative compared to the fire test results available. To establish the finite element analysis model that can be used to predict the thermal and structural behaviour of unprotected CFT columns in fire, the fully coupled thermal-stress analysis was also tried by using the commercial code ABAQUS. The numerical results showed a reasonable global correlation with the experimental results.

본 연구에서는 표준화재에 노출된 무피복 콘크리트충전강관(CFT)기둥의 내화성능 및 거동 특성을 파악하고자 화재실험 및 수치해석 연구를 수행하였다. 실험변수로는 기둥높이, 하중비, 단면크기를 고려하였고, 이들이 CFT 기둥의 내화성능에 미치는 영향을 알아보고자 단면내 온도변화 및 축변형을 분석하였다. 실험결과 모든 실험체의 강관에서 국부좌굴이 발생, 콘크리트로 하중전이가 일어났고, 이후 콘크리트 압괴로 이어졌다. 이는 CFT 기둥의 전체 휨좌굴과 함께 국부좌굴이 내화설계의 주요 변수로 고려되어야 함을 시사한다. 하중비가 증가할수록 콘크리트저항구간이 줄어들면서 전체적인 내화시간이 감소하였다. 강재한계온도에 근거한 합성부재의 내화성능평가는 실제 하중지지력에 의한 내화시간에 비해 다소 보수적임을 확인하였고, 기존 연구자들의 제안식에 의한 성능예측결과도 실제 내화성능과 비교해볼때 개선의 여지가 있었다. 화재시 CFT 기둥의 내화성능을 예측하기 위하여 유한요소해석을 수행하였고, 실험결과와 비교할 때 신뢰성 있는 예측값을 나타냄을 확인하였다.

Keywords

References

  1. Lie, T.T. and Chabot, M. (1992) Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled with Plain Concrete, Internal report No. 611, Institute for Research in Construction, National Research Council of Canada, Ottawa.
  2. Kodur, V.K.R. (1999) Performance-Based Fire Resistance Design of Concrete-Filled Steel Columns, Journal of Constructional Steel Research, Vol.51, pp.21-36. https://doi.org/10.1016/S0143-974X(99)00003-6
  3. Han, L.H. and Yang, Y.F. (2003) An Experimental Study and Calculation on the Fire Resistance of Concrete-Filled SHS and RHS Columns, Journal of Constructional Steel Research, Vol.59, No.4, pp.427-452. https://doi.org/10.1016/S0143-974X(02)00041-X
  4. Wang, Y.C. and Davis, J.M. (2003) An Experimental Study of the Fire Performance of Non-Sway Loaded Concrete-Filled Steel Tubular Column Assemblies with Extended end Plate Connections, Journal of Constructional Steel Research, Vol.59, No.7, pp.819-838. https://doi.org/10.1016/S0143-974X(02)00092-5
  5. 박수희, 류재용, 정경수, 최성모(2007) 일정 축력을 받는 콘크리트충전 각형 강관기둥의 내화성능 평가, 한국강구조학회논문집, 한국강구조학회, 제19권, 제6호, pp.703-714. (Park, S.H. Ryoo, J.Y., Chung, K.S., and Choi, S.M. (2007) An Evaluation for the Fire Resistance of Concrete-Filled Steel Square Tube Columns under Constant Axial Loads, Journal of Korean Society of Steel Construction, KSSC, Vol.19, No.6, pp.703-714 (in Korean)).
  6. 조경숙, 김흥열, 김형준, 권인규(2010) 콘크리트 압축강도 및 하중비에 따른 CFT 기둥의 내화성능에 관한 연구, 한국화재소방학회논문집, 한국소방학회, 제24권, 제2호, pp. 44-51. Cho, K.S., Kim. H.Y., Kim, H.J., and Kwon, I.K. (2010) The Study on the Fire Performance of the CFT Column according to the Concrete Compressive Strengths and Load Ratios, Journal of Korean Institute of Fire Science and Engineering, Vol.24, No.2, pp.44-51 (in Korean).
  7. 조경숙, 김흥열, 김형준, 민병렬, 권인규(2010) 강관의 크기, 축력비 및 콘크리트 압축강도 변화에 따른 CFT 기둥부재의 내화성능에 관한 실험적 연구, 한국화재소방학회논문집, 한국소방학회, 제24권, 제6호, pp.104-111. (Cho, K.S., Kim, H.Y., Kim, H.J., Min, B.Y., and Kwon, I.K. (2010) Experimental Study on Fire Resistance Performance of CFT Column according to Cross Section of Steel, Concrete Compressive Strengths and Load Ratios, Journal of Korean Institute of Fire Science and Engineering, Vol.24, No.6, pp.104-111 (in Korean)).
  8. 김선희, 원용안, 최성모(2012) 비재하 가열실험을 통한 이중강관 CFT 기둥의 잔존강도 평가연구, 한국강구조학회논문집, 한국강구조학회, 제24권, 제1호, pp.81-89. (Kim, S.H., Won, Y.A., and Choi, S.M. (2012) A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.1, pp. 81-89 (in Korean)). https://doi.org/10.7781/kjoss.2012.24.1.081
  9. 정경수, 최인락, 김도환, 김진호(2013) 일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제25권, 제1호, pp.71-80. (Chung, K.S., Choi, I.R., Kim, D.H., and Kim, J.H. (2013) Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.1, pp.71-80 (in Korean)). https://doi.org/10.7781/kjoss.2013.25.1.071
  10. 김성배, 김상섭, 유덕수, 최승관(2013) 신형상 U형 하이브리드 합성보의 내화성능에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제25권, 제4호, pp.379-388. (Kim, S.B., Kim, S.S., Ryu, D.S., and Choi, S.K. (2013) Fire Resistance of U-shape Hybrid Composite Beam, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.4, pp.379-388 (in Korean)). https://doi.org/10.7781/kjoss.2013.25.4.379
  11. Wang, Y.C. (2002) Steel and Composite Structures: Behaviour and Design for Fire Safety, Spon Press-Taylor & Francis Group.
  12. European Committee for Standardization (2005) Eurocode 4: Design of Composite Steel and Concrete Structures. - Part 1.2: General Rules-Structural Fire Design, British Standards Institution, London.
  13. 대한건축학회(2009) 건축구조기준(KBC 2009) (Architectural Institute of Korea (2009) Korea Building Code-Structural (in Korean)).
  14. NUNA (2004) Recommendation for Fire Resistance Design of Concrete-filled Steel Tube Structure, New Urban Housing Association.
  15. European Committee for Standardization (2005) Eurocode 3: Design of Steel Structures. - Part 1.2: General Rules- Structural Fire Design, British Standards Institution, London.
  16. ABAQUS (2010) ABAQUS analysis user's manual, SIMULIA.
  17. Ding, J. and Wang, Y.C. (2008) Realistic Modeling of Thermal and Structural Behavior of Unprotected Concrete Filled Tubular Columns in Fire, Journal of Constructional Steel Research, Vol.64, No.10, pp.1086-1102. https://doi.org/10.1016/j.jcsr.2007.09.014

Cited by

  1. Finite Element Analysis of H-Shaped Compressive Member Exposed High Temperatures vol.30, pp.5, 2016, https://doi.org/10.7731/KIFSE.2016.30.5.054
  2. An Evaluation on Fire Resistance Performances of CFT Columns According to Conditions Exposed to Fire vol.15, pp.3, 2015, https://doi.org/10.9798/KOSHAM.2015.15.3.155
  3. An Residual Capacity for Cold Forming Welded Built-up Square Mega Composite Columns Exposed to Fire vol.9, pp.1, 2018, https://doi.org/10.11004/kosacs.2018.9.1.054
  4. 원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가 vol.27, pp.1, 2014, https://doi.org/10.7781/kjoss.2015.27.1.119
  5. 재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정 vol.27, pp.4, 2015, https://doi.org/10.7781/kjoss.2015.27.4.387
  6. Experimental Study on the Fire Resistance of Steel-Reinforced Concrete Column in Fire According to Load Ratio vol.31, pp.6, 2014, https://doi.org/10.7781/kjoss.2019.31.6.459
  7. Fire behaviour of non-welded concrete-filled-tube columns with strip connectors vol.173, pp.1, 2020, https://doi.org/10.1680/jstbu.16.00170
  8. Prediction of Temperature Distribution and Strength of Unprotected Mega CFT Columns Exposed to Standard Fire vol.33, pp.1, 2014, https://doi.org/10.7781/kjoss.2021.33.1.001
  9. Evaluation of the Fire Resistance Performance and the Post-Fire Structural Performance for CFT Columns with Square-Shape Steel Tube vol.33, pp.1, 2014, https://doi.org/10.7781/kjoss.2021.33.1.011