Changes of Refractive Errors Caused by Corneal Shape and Pupil Size

각막지형과 동공크기에 의한 굴절교정값의 변화

  • 노연수 (강원대학교 안경광학과) ;
  • 김상엽 (강원대학교 안경광학과) ;
  • 문병연 (강원대학교 안경광학과) ;
  • 조현국 (강원대학교 안경광학과)
  • Received : 2014.08.01
  • Accepted : 2014.09.18
  • Published : 2014.09.30

Abstract

Purpose: To investigate the effect of corneal unique shape to changes of refractive full corrections when pupil size changes. Methods: Subjective refraction for monocular full correction was performed to 30 subjects ($23.33{\pm}1.78$ of age, 60 eyes) in two room conditions, 760 lx and 2 lx, respectively. Pupillary diameter was measured in two conditions and the change pattern was analyzed using a peak data of corneal topography. Results: Pupillary diameter was 3.74~4.00 mm in 760 lx and 5.52~5.90 mm in 2 lx. By comparison with refractive data in 760 lx, those data in 2 lx was changed as follows: more (-) spherical power of 17 eyes (28.3%), more (+) spherical power of 10 eyes (17.7%), more (-) cylinderical power of 17 eyes (28.8%), less (-) cylinderical power of 9 eyes (15.3%), and astigmatic axis rotation of 36 eyes (62.1%). From peak data of corneal topography, the changing pattern of two principal meridians was classified into 4 types. Conclusions: Expansion of the corneal refractive surface accompanied with pupillary dilation may be a main factor that effects the changing a values of subjective refraction because of unique corneal shape. Therefore, subjective refraction should be performed under the nearest lighting condition to a main living environment.

목적: 동공크기가 달라질 때 각막의 고유한 형태가 굴절검사 완전교정값에 미치는 영향을 조사하였다. 방법: 평균연령 $23.33{\pm}1.78$세의 30명(60안)을 대상으로 검사실 조도 760 lx와 2 lx에서 각각 자각적굴절검사를 실시하여 단안 완전교정하고, 동공의 크기를 측정하였다. 그리고 각막지형을 측정한 후 peak data를 이용하여 각막지형의 변화를 분석하였다. 결과: 검사실 조도 760 lx에서 측정된 동공크기는 3.74~4.00 mm, 2 lx에서는 5.52~5.90 mm로 측정되었다. 760 lx에서 2 lx로 조도가 변화될 때 (-)구면굴절력이 증가한 경우는 17안(28.3%), (+)구면굴절력이 증가한 경우는 10안(16.7%), (-)원주굴절력이 증가한 경우는 17안(28.8%), (-)원주굴절력이 감소한 경우는 9안(15.3%), 그리고 난시축이 변화한 경우는 36안(62.1%)이었다. 각막지형측정에서 나타난 peak data 분석 결과 각막 주경선의 변화는 4가지 형태로 분류되었다. 결론: 동공확대에 따른 각막굴절면 확장은 각막의 고유한 형태로 인해 자각적굴절 검사값을 변화시키는 요인으로 작용하므로, 자각적굴절검사는 주된 생활환경에 맞는 조도조건에서 실시하여야 한다.

Keywords

References

  1. Han SH, Kim BH, Yoon JH, Lee SE, Park SM, Jeong, et al. Change in the eye's refractive power and pupil's size following intensity of illumination using Auto Ref-Keratometer. J Korean Vis Sci. 2013;15(1):1-7.
  2. Michaels DM. Subjective methods of refraction. In Michaels DM (Ed), Visual Optics and Refraction, 3rd Ed. St. Louis: CV Mosby. 1985;316-334.
  3. Ivanoff A. About the spherical aberration of the eye. J Opt Soc Am. 1956;46(10):901-903. https://doi.org/10.1364/JOSA.46.000901
  4. Howarth PA, Bradiey A. The longitudinal chromatic aberration of the eye and its correction. Vision Res. 1986;26(2): 361-366. https://doi.org/10.1016/0042-6989(86)90034-9
  5. Rabin J. Luminance effects on visual acuity and small letter contrast sensitivity. Optom Vis Sci. 1994;71(11):685-688. https://doi.org/10.1097/00006324-199411000-00003
  6. Lee EJ, Yoon MJ, Kim SH, Yang GT, Jeong JH, Kim HJ, et al. Changes of contrast sensitivity with decreasing luminance in photopic conditions. J Korean Ophthalmic Optics Soc. 2012;17(4):411-417.
  7. Kim SY, Cho HG. Minimal illumination to identify the chart in each visual acuity and deviation of identification capability according to illumination and chart contrast. J Korean Ophthalmic Optics Soc. 2013;18(4):549-554. https://doi.org/10.14479/jkoos.2013.18.4.549
  8. Rosenfield M, Ciuffreda KJ, Hung GK, Gilmartin B. Tonic accommodation: A review. I. Basic aspects. Ophthal Physiol Opt. 1993;13:266-284. https://doi.org/10.1111/j.1475-1313.1993.tb00469.x
  9. Rosenfield M, Ciuffreda KJ, Hung GK, Gilmartin B. Tonic accommodation: A review. II. Accommodative adaptation and clinical aspects. Ophthal Physiol Opt. 1994;14(3): 265-277. https://doi.org/10.1111/j.1475-1313.1994.tb00007.x
  10. Jenkins TCA. Aberrations of the eye and their effects on vision: Part II. Br J Phys Opt. 1963;161-201.
  11. Le Grand Y. Form and Space Vision (translated by Millodot M, Heath GG), rev ed. Bloomington : Indiana University Press. 1967.
  12. Chee CK, Kang WG, Kim CS. The survey on the design standard for the illumination level. Proceeding of KIIEE. 1988;2(3):59-66.
  13. Smith G. Relation between spherical refractive error and visual acuity. Opt Vis Sci. 1991;68(8):591-598. https://doi.org/10.1097/00006324-199108000-00004
  14. Kim JH, Kim IS. A study on the relationship between the disc of least confusion and corrected vision of astigmatism. J Korean Ophthalmic Optics Soc. 2008;13(2):51-57.
  15. Kim JH, Kang SA. A study on the relatioship between the off-axis cylinder and corrected vision of astigmatism. J Korean Ophthalmic Optics Soc. 2007;12(3):83-87.

Cited by

  1. Effects of Variation of Illumination on Visual Function Factors vol.20, pp.2, 2015, https://doi.org/10.14479/jkoos.2015.20.2.195
  2. Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe vol.26, pp.5, 2016, https://doi.org/10.4283/JKMS.2016.26.5.168
  3. Effects of Illumination-Dependent Pupil Size on Higher Order Aberration vol.20, pp.3, 2014, https://doi.org/10.17337/jmbi.2018.20.3.313
  4. The effect of uncorrected ametropia on ocular torsion induced by changes in fixation vol.9, pp.None, 2014, https://doi.org/10.7717/peerj.11932
  5. Comparison of Corneal Aberration and Contrast Sensitivity for WTR-Astigmatism according to the Prescription Method of Soft Contact Lenses vol.26, pp.3, 2014, https://doi.org/10.14479/jkoos.2021.26.3.181