Abstract

Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

Keywords

References

  1. Lee, S. B., 1995, An Evaluation of Airtihtness Performance and Analysis of Energy Saving Potential in Apartment Housing, Journal of Korean Solar Energy Society, Vol. 15, No. 3, pp. 119-125
  2. Lee, Y. G., and Shin, C. W., 2013, The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apatment, Korean Journal of Air-Conditioning and Refirigeration Engineering, Vol. 25, No. 11, pp. 606-611 https://doi.org/10.6110/KJACR.2013.25.11.606
  3. Shin, H. K., and Jo, J. H., 2011, Comparison of Test Conditions of the Fan Pressurization Method in measuring the Building Airtightness, Architectural Institute of Korea, Vol. 27, No. 8, pp. 279-286
  4. Yoon, J, O,. 2013, Field Measurement of Infiltration in New Apartments using De-Pressurization method, Korean Journal of KIEAE, Vol. 13, No. 3, pp. 27-32 https://doi.org/10.12813/kieae.2013.13.3.027
  5. Lee, T, G., and Yun, D. Y., 2013, The measurement study on the airtightness of dwellings based on the passive design, Korean Journal of KIEAE, Vol. 13, No. 2, pp. 13-20 https://doi.org/10.12813/kieae.2013.13.2.013
  6. Shin, U, C., Yoon, J, H., and Baek, N. C., 2005, Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction, Journal of Korean Solar Energy Society, Vol. 25, No. 4, pp. 61-67
  7. Yoon, J, H., Park, J. W., Lee, K. S., Baek, N. C., and Shin, U. C., 2008, A Study on the Measurement of Airtightness Performance of Detached Houses in chung-cheong area, Journal of Korean Solar Energy Society, Vol. 28, No. 5, pp. 65-71
  8. Kim, K, L., Kim, J. H., and Kim, H. Y., 2008, Analysis of the air exchange rate which follows in airtightness performance of the studio building, Proceedings of the AIK-PK, n.2008, v.01(2008-12)
  9. Statistics Korea, 2010, Population and Housing Census(Household .Housing)
  10. Korean Standard Information Center, Thermal Insulation-Determination of building airtightness-Fan Pressurization method, KS L ISO 9972.
  11. Korean Standard Information Center, The method of air tightness for windows and doors, KS F 2292.
  12. Jo, J. H., 2010, Measurements of the Dwelling Unit Airtightness in High-rise Residential Buildings, Architectural Institute of Korea, Vol. 26, No. 10, pp. 337-344
  13. Kwon, O. H., Kim, J. H., Kim, M. H., Seok, Y. J., and Jeong, J. W., 2010, Case Sutdy of Residential Building Air Tightness in Korea based on Blower Door Test Approach, Architectural Institute of Korea, Vol. 26, No. 7, pp. 303-310
  14. Seo, J. Y., and Yoon, J. O., 2012, Field Measurement of Infiltration in Apartment with Depressurization Method, Proceedings of the AIK, Vol. 32, No. 2, pp 293-294
  15. Shin, C. W., and Lee, Y. G., 2012, A Study on Airtightness Performance of Apartments adoption Ventilation System, Proceedings of the SAREK, 2012, 6, pp 342-345