Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe

연질 PE관을 이용한 여름딸기 부분냉방기술 개발

  • Received : 2014.10.22
  • Accepted : 2014.11.18
  • Published : 2014.11.30

Abstract

The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

Keywords

References

  1. Jun, H. J., J. G. Hwang, M. J. Son, and D. J. Choi, 2008. Effect of root zone temperature on root and shoot growth of strawberry, Journal of Bio-Environment Control 17(1): 14-19 (in Korean)
  2. Kim, K. D., E. H. Lee, W. B. Kim, J. G. Lee, D. L. Yoo, Y. S. Kwon, J. N. Lee, S. W. Jang and S. C. Hong, 2011. Effects of Several Cooling Methods and Cool Water Hose Bed Culture on Growth and Microclimate in Summer Season Cultivation of Narrowhead Goldenray 'Ligularia stenocephala'. journal of Bio-Environmental Control 20(2): 116-122(in Korean)
  3. Kim, K. D., Y. S. Ha, K. M. Lee, D. H. Park, S. G. Kwon, J. M. Park and S. W. Chung, 2010a. Development of Temperature Control Technology of Root Zone using Evaporative Cooling Methods in the Strawberry Hydroponics, Journal of Bio- Environment Control 19(4):183-188(in Korean)
  4. Kim, K. D., Y. S. Ha, K. M. Lee, D. H. Park, S. H. Kwon, W. S. Choi and S. W. Chung, 2010b. Development of Temperature Control Technology of Root Zone using Multi-line Heating Methods in the Strawberry Hydroponics, Journal of Bio- Environment Control 19(4):189-194(in Korean)
  5. Kim, T. Y., Y. H. Woo, I. H. Cho, K. D. Kim and J. W. Lee, 2002. Effects of Energy Saving on Partial Heating for Pot Flower Bench Cultivation, Proceedings of the 2002 Annual Conference of the Korean Society for Bio-Environment Control Conference, 44-47(in Korean)
  6. Lee, J. N.,J.G. Lee, E. H. Lee, H. J. Kim, and S. W. Jang, 2010, Breeding of New Ever-bearing Strawberry 'Gangha' for Summer Culture, Korean Journal of Horticultural Science and Technology 28(3): 515-518(in Korean)
  7. Lee, K. J., Y. C. Kwon, C. K. Chun, S. J. Park, J. T. Kwon and C. Huh, 2011. Experimental Study on Heating Performance Characteristics of Air Source Heat Pump with Air to Water Type, Journal of Air-Conditioning and Refrigeration Engineering 23(6):400-405 (in Korean) https://doi.org/10.6110/KJACR.2011.23.6.400
  8. Nam, S. W., 2002. Estimation of Soil Cooling Load in the Root Zone of Greenhouses, Journal of Bio-Environment Control 11(4):151-156(in Korean)
  9. Nam, S. W., Y. S. Kim and D. U. Seo, 2014. Change in the Plant Temperature of Tomato by Fogging and Airflow in Plastic Greenhouse, Protected Horticulture and Plant Factory 23(1): 11-18(in Korean) https://doi.org/10.12791/KSBEC.2014.23.1.011
  10. Park, J. W., Y. S. Ha, K. D. Kim, D. H. Park, K. M. Lee, H. J. Jun, S. G. Kwon, W. S. Choi and S. W. Chung, 2010. Modeling of Medium Temperature Drops of the Elevated-bench Hydroponics for Strawberry Cultivation during Low Temperature Season, Journal of Bio-Environment Control 19(3):123-129(in Korean)
  11. Ryou, Y. S., Y. G. Kang, Y. J. Kim, and K. C. Kang, 2008. Heating and Cooling Effect of Portected Horticulture by Geothermal Heat Pump System with Horizontal Heat Exchanger, Proceedings of the 2008 spring annual conference of The Korean society for New and Renewable Energy, 630-633(in Korean).