Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by CBD System

CBD 시스템으로 보강된 비내진 RC 골조의 내진성능 평가

  • Received : 2015.02.24
  • Accepted : 2015.09.14
  • Published : 2015.12.30

Abstract

In this study, a comparative analysis have been conducted to examine seismic reinforcement effect of a school building that is designed with a CBD (Channel Beam Damper) system supported by H-frame with existing non-seismic RC frame. As a result of experiment, seismic reinforcement specimen with CBD system showed hysteretic characteristics of a large ellipse with great energy dissipation ability and increased strength and stiffness, while non-seismic design specimen showed rapid reduction in strength and brittle shear failure at top and bottom of the left and right column. In addition, comparing the stiffness reduction between the two specimens, CBD system was effective in preventing the reduction of stiffness. Energy dissipation ability of specimen reinforced by CBD system was about 4.0 times higher than the non-reinforced specimen. Such enhancement in energy dissipation ability could be considered as the result of improved strength and deformation for further application in designing of seismic reinforcement.

본 연구에서는 내진설계 이전에 지어진 학교 건물을 대상으로 내진보강효과를 알아보기 위하여 CBD 시스템을 설치하여 기존 비내진 설계된 보강 RC골조 실험결과와 비교 분석하였다. 실험결과, 비내진 설계된 실험체는 좌 우측 기둥의 상 하부에 피해가 집중되면서 급격한 강도저하와 함께 취성적인 전단파괴의 양상을 나타낸 반면, CBD 시스템을 보강한 실험체는 강도 및 강성의 증가와 함께 탄소성 거동을 보이면서 에너지 흡수 능력이 큰 타원형의 이력특성을 나타내었다. 또한, 두 실험체의 강성저하를 비교한 결과 CBD 시스템을 보강한 실험체가 강성저하를 방지하는데도 효과적임을 알 수 있었다. 에너지소산능력도 CBD 시스템을 보강한 실험체가 비보강 실험체에 비해 약 4.0배의 향상된 결과를 나타내었다. 이러한 에너지소산능력의 증진은 내력과 변형 능력의 증진에 따른 결과라고 사료된다. 본 연구에서 제안하는 CBD 시스템을 적용할 경우 비내진 상세를 갖는 철근콘크리트 골조의 내력 증진 및 안전성 확보를 위해 국내 내진기준에서 요구하는 허용층간변형각 기준을 만족하도록 보강하는데 용이하게 적용될 수 있을 것으로 판단된다.

Keywords

References

  1. Oh, S. H., Ryu, H. S., and Kim, Y. J., "Structural Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers", Journal of EESK, 2005, pp.552-559.
  2. Oh, S. H., and Kim, Y. J., "Hysteretic Behavior of Beam-to-Column Connections with Slit Plate Dampers", Journal of AIK, Vol.21, No.12, 2005, pp.101-108.
  3. Lee, H. H., "Yield Strength Evaluation of Slit Shaped Metallic Damper", Proceedings of the Korea Concrete Institute, Vol.22, No.2, 2010, pp.239-240.
  4. Choi, K. S., Kim, H. R., Kim, J. H., and You, Y. C., "Hysteretic Behavior of Steel Slit Damper with Different Aspect Ratio", Proceedings of the Korea Concrete Institute, Vol.23, No.2, 2011, pp.17-18.
  5. Lee, H. H., and Kim, S. I., "Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape", Journal of KSMI, Vol.15, No.5, 2011, pp.199-208.
  6. Lee, H. H., "Displacement and Velocity Dependence of Clamped Shape Metallic Dampers", Journal of KSMI, Vol.17, No.2, 2013, pp.62-70.
  7. Beak, E. L., Oh, S. H., and Lee, S. H., "Seismic performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper", EESK J Earthquake Eng, Vol.18, No.5, 2014, pp.241-251.
  8. KBC, Korean Building and Commentary, Architectural Institute of Korea, 2009.
  9. ACI Committee 374, "Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary", ACI 374.1-05.