Abstract
Current domestic research is to demonstrate the effectiveness and efficiencies of flood prevention measures through one-dimensional numerical analysis and this study's object is to help water managers to make the efficient decisions by applying the two-dimensional urban run off model XP-SWMM model in the flooded area and comparing with the flood prevention measures. Statistics were analyzed, based on the data collected from Cheongju Weather Service from 1967 to 2011 for 45 years. 50 years Flood frequency simulations of water flow capacity analysis of the target area for flooded areas $539,548m^2$, inundation depth 1.0 m, was analyzed by inundation time of 48 minutes. When comparing with the constructions of bypass road and underground storage facilities to increase the water flow capacity of A1 small drainage areas as flood protection, if you install a batching target underground detention basin with a capacity of $13,500m^3$, it is expected that the flood by rainfall with frequency of 50 years will be resolved completely. In preparation for extreme weather in the future flood mitigation measures, underground storage tank installation is considered a better efficient way.
현재 국내 연구는 1차원 수치해석을 통한 침수방지대책의 효과분석 및 효율성을 입증하는 형태로 본 연구에서는 2차원 도시유출모형인 XP-SWMM 모형을 침수지역에 적용, 침수방지대책을 상호 비교 분석함으로써 수자원관리자의 효율적인 정책결정에 반영할 수 있도록 하는 것이 본 연구의 목적이다. 기상데이터는 지난 1967년부터 2011년까지 45년간 청주 기상대에서 수집한 것으로 통계 분석하여 사용하였다. 대상 배수구역 통수능력 분석을 50년 빈도 모의 결과 침수면적 $539,548m^2$, 최대침수심 1.0m, 침수시간 48분으로 분석되었다. 침수대책으로 A1 소배수구역의 통수능력 증대를 위해 우회수로 및 지하저류시설 건설을 비교한 결과 대상유역에 용량이 $13,500m^3$인 지하저류시설을 설치할 경우 50년 빈도의 강우까지 침수가 완전 해소될 것으로 판단된다. 향후 침수 저감대책으로 이상기후에 대비할 수 있는 지하저류조 설치가 효율성이 좋을 것으로 판단된다.