DOI QR코드

DOI QR Code

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung (Dept. of Building Equipment & Fire Protection System, Chungwoon Univ.) ;
  • Lee, Myung-Eun (Dept. of Architectural Engineering, Suwon Univ.)
  • Received : 2015.10.16
  • Accepted : 2015.11.23
  • Published : 2015.12.31

Abstract

Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

Keywords

References

  1. 최경석, "적외선열화상 측정법에 의한 건축물 단열성능 현장평가에 관한 연구", 박사학위논문, 한양대학교. 2010 // (Choi, Gyeong-Seo, On-site Evaluation for Thermal Performance of Building Envelopes using an Infrared Method, Department of Architectural Engineering Graduate School, Hanyang University, 2010)
  2. 최보혜, 강재식, "건축용 단열재의 장기 경시변화에 따른 열성능 특성", 대한설비공학회 논문집, 제 25권 제 11호, 2013 // (Choi, Bo-Hye, Kang, Jae-Sik, "The Thermal Performance of Building Insulation Materials According to Long-Term Aging, Korean Journal of Air-Conditioning and Refrigeration Engineering", Vol.25, No. 11, 2013)
  3. 박세영, "공동주택 결로 방지 설계기준 개선에 관한 연구", 석사학위논문, 성균관대학교, 2014 // (Park, Se-Young, A study on the improvement of the condensation prevention standards in residential buildings, Department of Convergence Engineering for Future City Sungkyunkwan University, 2014)
  4. 전찬울, 김현수, 정수현, 김영탁, 송두삼, "공동주택 결로 방지에 관한 국내외 기준 비교", 대한설비공학회 하계학술발표대회 논문집, 대한설비공학회, 2013 // (Jeong, Chan-woul, Kim, Hyun-Soo, Jeong Su-Hyeon, kim, Young-Tak, Song, Doo-sam, Comparison and Analysis of Domestic and Foreign Standards for Preventing the Condensation in Multi-residential House, Korean Journal of Air-Conditioning and Refrigeration Engineering, 2013)
  5. 박정훈, "공동주택의 단열성에 관한 분석 및 단열보강 적용에 관한 연구", 석사학위논문, 공주대학교, 2014 // (PARK, Jung-Hun, An Analysis of Thermal Insulation and a Study of Application of Reinforced Insulation in Apartment Houses, Department of Architectural Material Graduate School of Kong-ju National University, 2014)
  6. Moore, Patrick O, "Nondestructive Testing Handbook : Infrared & Thermal Testing, American Society for Nondestructive Testing", 2001
  7. Akira Hoyano, Kohichi Asano, Takehisa Kanamaru, "Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography", Atmospheric Environment 33, 1999
  8. ISO 9869: 1994, "Thermal insulation - Building elements - In-situ measurement of thermal resistance and thermal transmittance", 1994
  9. FLIR System, "FLIR BuildIR-User's Manual", 2010

Cited by

  1. Integrated BIM-Parametric Workflow-Based Analysis of Daylight Improvement for Sustainable Renovation of an Exemplary Apartment in Seoul, Korea vol.11, pp.9, 2019, https://doi.org/10.3390/su11092699