This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. Several case studies were conducted to experimentally evaluate their impact on BIM-based energy analysis to calculate energy load. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.

Keywords

References

  1. U.S. General Services Administration, GSA BIM Guide for Energy Performance, 2012.
  2. U.S. Department of Energy, 2010 U.S. DOE buildings energy databook, 2010.
  3. Y. Ham, M. Golparvar-Fard, "Mapping actual thermal properties to building elements in gbXML-based BIM for reliable building energy performance modeling", Automation in Construction, vol. 49, Part B pp. 214-224, 2015. https://doi.org/10.1016/j.autcon.2014.07.009
  4. S. Laguela, L. Diaz-Vilarino, J. Martinez, J. Armesto, "Automatic thermographic and RGB texture of as-built BIM for energy rehabilitation purposes", Automation in Construction, vol. 31, pp. 230-240, 2013. https://doi.org/10.1016/j.autcon.2012.12.013
  5. S. Laguela, L. Diaz-Vilarino, J. Armesto, P. Arias, "Non-destructive approach for the generation and thermal characterization of an asbuilt BIM", Construction and Building Materials, vol. 51, pp. 55-61, 2014. https://doi.org/10.1016/j.conbuildmat.2013.11.021
  6. Y. Ham, M. Golparvar-Fard, "An automated vision-based method for rapid 3D energy performance modeling of existing buildings using thermal and digital imagery", Advanced Engineering Informatics, vol. 27, pp. 395-409, 2013. https://doi.org/10.1016/j.aei.2013.03.005
  7. P.A. Fokaides, S.A. Kalogirou, "Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes", Applied Energy, vol. 88, no. 12, pp. 4358-4365, 2011. https://doi.org/10.1016/j.apenergy.2011.05.014
  8. Y. Ham, M. Golparvar-Fard, "3D Visualization of Thermal Resistance and Condensation Problems in Infrared Thermography for Building Energy Diagnostics", Visualization in Engineering, vol. 2, no. 12, 2014.