DOI QR코드

DOI QR Code

Development of a Collapse-sensing Phone and Collapse Recognition Algorithm

낙상 감지 폰의 개발과 낙상판단 알고리즘

  • Received : 2014.10.30
  • Accepted : 2015.01.28
  • Published : 2015.02.28

Abstract

To deal with the emergency of the solitary aged people, we have developed a collapse-sensing phone, in which a collapse sensor, a GPS receiving chipset and a CDMA sending chipset are included. The general cellular phone is somewhat expensive communication device using sound and characters, but the collapse-sensing phone is a cheaper and popular version. If the collapse sensor recognizes a certain of collapse of the aged people, CDMA sending chipset will send the location of the phone which is received from satellite by GPS receiving chipset. In this paper, a collapse recognition algorithm which is developed by using much experimental data, will be introduced to explain how to recognize the real collapse from fast sitting or immediate standing after collapse. Once a true collapse is ecognized, the phone-ID and the coordinate will be sent to the server of administrative office via CDMA network. And the position of emergency will be displayed on the GIS with the rescue center.

Keywords

References

  1. K.Y. Jee, M.H. Lee, J.W. Seo, T.B. Kim, "Current Status and Future Prospects of the e-Health Market," Electronics and Communications Trends, Vol. 19, No. 2, pp. 90-100, 2004 (in Korean).
  2. Health Industry Center, Final Reports of R&D Construction Supporting for Certification and Industrialization of Senior-Friendly Products, Keimyung University, 2008.
  3. D.Y. Koh, H.S. Cho, "A Survey of Consumer's Perception for u-Health Service and a Preview its Policy," KIET Industrial Economic Review, Vol. 12, No. 1, pp. 3-15, 2011 (in Korean).
  4. Freescale Semiconduct, MMA7260Q Technical Data, http://www.freescale.com, 2005.
  5. F. Astinet, M. Langer, A. Kem, "A PACS-experiences and future development," Computer Assisted Radiology, pp. 398-406, 1991.
  6. Wikipedia, Microsoft Health Vault, http://en.wikipedia.org/wiki/Microsoft_HealthVa ult, 2007.
  7. B. Smith, "Health Care MVNO Planned," WirelessWeek, http://www.wirelessweek.com/articles, 2007.
  8. S.J. Kim, W.Y. Chung, D.U. Jeong, "A Development of the Context Awareness Algorithm Using 3-Axis," Proceedings of Annual Conference on the Institute of Electronics and Information Engineers, Vol. 30, No. 1, pp. 1031-1032, 2007 (in Korean).
  9. J.H. Kim, C.W.Lee, "Design and Implement a Gateway Based on Mobile Device and Web Monitoring System for u-Healthcare Service," IEMEK J. Embed. Sys. Appl., Vol. 4, No. 3, pp. 126-133, 2009 (in Korean).
  10. D.W. Kim, "A Study on Wearable Emergency Medical Alarm System," Master Thesis, Myongji Univiversity, 2006 (in Korean).
  11. D.S. Jang, D.Y. Choi, H.J. Kim, S.C. Choi, T.S. Park, "Location Identification for Indoor Emergency," Proceesings of 31th Korea Information Processing Society Spring Conference, Vol. 16, No.1, pp. 620-622, 2009 (in Korean).
  12. D.S. Jang, S.C. Choi, T.S. Park, "Development of Collapse-Sensing Phone for Emergency Positioning System," Proceedings of International Conference on Information Technology, pp. 1649-1652, 2009.
  13. NAVIUS, Specification for NSAC3M4122A, http://www.navius.co.kr, 2007.
  14. YISO Wireless CO., M802F User's Guide, Ver. 1.0, http://www.yiso.co.kr, 2008.