DOI QR코드

DOI QR Code

A Comparative Evaluation on the Thermal Insulation Performance of Windows according to the Temporary Improvement Method

창호의 단열성능 간이 개선방법의 비교 분석

  • Received : 2014.09.29
  • Accepted : 2014.12.08
  • Published : 2015.02.28

Abstract

The purpose of this study is to compare the thermal insulation performance of windows according to the formation of air layer and to evaluate its energy efficiency on a selected standard house. A thermal insulation test, KS F 2278 was used to measure U-values (Heat transmission coefficients) for the following three cases: the first case (Case 1) is a Low-E pair glass (Argon injected), the second case (Case 2) is a Low-E pair glass with the air cap attached on the glass surface, and the third case (Case 3) is a Low-E pair glass, on the frame of which the air cap is attached. The evaluation of the energy efficiency was conducted according to a building energy calculation method from ISO 13790, calculation of energy use for space heating and cooling, using the U-values obtained from the thermal insulation tests. As results of the tests, the U-values of Case 1, Case 2, and Case 3 were $1.668W/m^2{\cdot}K$, $1.568W/m^2{\cdot}K$, and $1.319W/m^2{\cdot}K$ respectively. The Case 2 had about 5.9% lower value than the Case 1, and the Case 3 had about 20.9% lower value than the Case 1. It seems that the thermal performance of the windows is attributed to an increase of the heat resistance and the thickness of air layer. An evaluation of the energy efficiency of the three cases on the selected standard house showed that the amount of heating energy demand per unit area was $7.776kWh/m^2{\cdot}yr$ for the Case $1,6.856kWh/m^2{\cdot}yr$ for the Case 2, and $4.856kWh/m^2{\cdot}yr$ for the Case 3. This study suggests that the formation of air layer (by using air cap) and its thickness should reduce the heat energy demand and thus improve the energy saving efficiency

Keywords

References

  1. Jang, Cheol-Yong, "A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating", Journal of Korean Solar Energy Society Vol.30 No.1 2010. 2.
  2. Jang, Cheol-Yong, "The technical Status of Windows", Journal of Korean Society of Mechanical Engineers Vol.50 No.7 2010. 7.
  3. Lee, Jin-Sung, "Estimation of Insulation Performance Forecast Formula According to the Window Components", Journal of Architectural Institute of Korea Vol.25 No.5 2009. 5.
  4. Korea Standard Information Center, "Test Method of Thermal Resistance for Windows and Doors", 2008
  5. James R. Welty et al, "Fundamentals of Momentum, Heat and Mass transfer (5th edition)", John Wiley and Sons 2007.
  6. W. Feist, "PHPP(Passive House Planning Package)", Passiv Haus Institut, 2007
  7. Kwak, Hee-Jeong, "A Study on the Gain Utilization Factor of Energy Demand in Monthly method of ISO 13790", Korean Institute of Architectural Sustainable Enviroment and Building System 2012. 10.
  8. ISO 13790, "Calculation of energy use for space heating and cooling", International Organization for Standardization, 2008
  9. Ministry of Land, Infrastructure and Transport, "Building Energy Conservation Design Standards", 2011

Cited by

  1. Development of Window-Mounted Air Cap Roller Module vol.11, pp.7, 2018, https://doi.org/10.3390/en11071909
  2. Estimation on effective thermal conductivities of air cavities using thermal conduction analysis vol.18, pp.6, 2018, https://doi.org/10.12813/kieae.2018.18.6.147