DOI QR코드

DOI QR Code

Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System

수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발

  • Received : 2015.03.05
  • Accepted : 2015.03.24
  • Published : 2015.03.31

Abstract

In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.

Keywords

References

  1. Y. Zhang, C. Li, D. Liu, Y. Zhang, and Y. Liu, "Monte carlo simulation of a NaI(Tl) detector for in situ radioactivity measurements in the marine environment", Appl. Radiat. Isot., Vol. 98, pp. 44-48, 2015. https://doi.org/10.1016/j.apradiso.2015.01.009
  2. H. M. Park, H. S. Hong, J. H. Kim, and K. S. Joo, "Development of a portable device based wireless medical radiation monitoring system", J. Radiation. Protection., Vol. 39, No 3, pp. 150-158, 2014. https://doi.org/10.14407/jrp.2014.39.3.150
  3. J. Y. Yeom, S. Yamamoto et al., "First performance results of Ce:GAGG scintillation crystals with silicon photomultipliers", IEEE Trans. Nucl. Sci., Vol. 60, No. 2, pp. 988- 992, 2013. https://doi.org/10.1109/TNS.2012.2233497
  4. H. M. park, and K. S. Joo, "Development of a wireless gamma-ray probe for diagnosing and evaluation of its effectiveness", I. J. Electronics. Information. Engineers., Vol. 52, No. 2, pp. 355-363, 2015.
  5. R. Casanovas, J. J. Morant, and M. Salvadoo, "Implementation of gamma-ray spectrometry in two real-time water monitors using NaI(Tl) scintillation detectors", Appl. Radiat. Isot., Vol. 80, pp. 49-55, 2013. https://doi.org/10.1016/j.apradiso.2013.06.003
  6. K. W. Jang, D. H. Cho, W. J. Yoo, J. K. Seo, J. Y. Heo, B. S. Lee, J. H. Moon, B. G. Park, S. Kim, and Y.H. Cho, "Measurements of thermal neutron distribution of nuclear fuel using a plastic fiber-optic sensor", J. Sensor Sci. & Tech., Vol. 18, No. 5, pp. 402-407, 2009. https://doi.org/10.5369/JSST.2009.18.5.402