DOI QR코드

DOI QR Code

Force-Deformation Relationship of Bearing-Type Bolted Connections Governed by Bolt Shear Rupture

볼트 전단파단이 지배하는 지압형식 볼트접합부의 힘-변형 관계

  • Received : 2014.03.11
  • Accepted : 2014.08.02
  • Published : 2015.02.27

Abstract

Well-designed bolted connections can exhibit excellent ductile behavior through bearing mechanism until the occurrence of bolt shear rupture. The ultimate strength analysis of eccentric bolted connections is an economical and mechanistic approach which uses such ductility. However, the bolt load-deformation relationship, which forms basis of the current practice, is based on very limited combinations of bolt and steel materials. The primary objective of this study was to establish the general bolt force-deformation relationship based on systematic single-bolt bearing connection tests. The test results showed that the projected area of the bolt hole and the strength and thickness of the plate to be connected are the main factors affecting the force-deformation relationship. The results of this study can be used for the instantaneous center of rotation method (ICRM) to achieve more accurate analysis and economical design of a variety of group-bolted connections subjected to eccentric shear.

잘 접합된 볼트접합부는 볼트의 전단파단이 발생할 때 까지 지압 메커니즘에 의하여 훌륭한 연성거동을 보인다. 이러한 볼트접합부에 내재된 연성 능력을 최대한 활용한다면 중력하중, 풍하중, 지진하중 등 다양한 하중에 대하여 활용하여 접합비용의 경제성 제고에 기여할 수 있다. 편심하중을 받는 볼트접합부의 경우 보수적인 탄성해석법과 합리적으로 볼트접합부의 연성거동을 활용할 수 있는 극한강도 해석법이 존재하나 기존의 극한강도해석법은 오늘날 다양한 소재와 설계조건의 다양화에도 불구하고 하나의 소재와 조건으로 이루어진 실험식에 의존하고 있다. 본 연구의 주된 목적은 체계화된 단일볼트의 실험을 기반으로 볼트의 일반화된 힘-변형 관계식을 정립하는 것이다. 실험결과를 토대로 볼트접합부의 기하학적인 요소(볼트의 직경, 플레이트의 두께) 및 강도가 힘-변형 관계에 주된 영향을 미치는 요소라는 것을 알 수 있다. 실험결과를 순간중심회전법에 적용하여 보다 정확하고 경제적인 편심하중을 받는 군볼트 접합부 설계가 가능하다.

Keywords

References

  1. 이철호, 김재훈(2005) 웨브를 볼트로 접합한 보 플랜지 절취형(RBS) 철골모멘트접합부의 내진설계 및 성능평가, 한국강구조학회논문집, 한국강구조학회, 제17권, 제6호, pp.689-697. Lee, C.H. and Kim J.H. (2005) Seismic Design and Testing of Reduced Beam Section Steel Moment Connections with Bolted Web Attachment, Journal of Korean Society of Steel Construction, KSSC, Vol.17, No.6, pp.689-697 (in Korean).
  2. 신경재, 임보혁, 이수헌, 최성모(2011) 웨브를 볼트로 접합한 보-기둥 접합부의 유한요소해석, 한국강구조학회논문집, 한국강구조학회, 제23권, 제3호, pp.305-316. Shin, K.J., Lim, B.H., Lee, S.H., and Choi, S.M. (2011) FEA of beam-column connection with bolted web, Journal of Korean Society of Steel Construction, KSSC, Vol.23, No.3, pp.305-316 (in Korean).
  3. 양승현(2012) 표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화, 한국강구조학회논문집, 한국강구조학회, 제24권, 제5호, pp.605-612. Yang, S.H. (2012) Change of Strength of High-Strength Bolted Connection Depending of Standard and Over Bolt Hole, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.5, pp.605-612 (in Korean).
  4. 김태수, 김민성(2012) 페라이트계 스테인리스강(STS430) 이면전단 볼트접합부의 구조거동에 관한 실험적 연구, 한국강구조학논문집, 한국강구조학회, 제24권, 제5호, pp. 463-474. Kim, T.S. and Kim, M.S. (2012) An Esperimental Study on Structural Behavior of Double Shear Bolted Connections Fabricated with Ferritic Stainless Steel (STS430), Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.5, pp.463-474 (in Korean).
  5. 김지훈, 김태수, 강현식(2013) 페라이트계 스테인리스강 2행 2열 일면전단 볼트접합부의 최대내력평가, 한국강구조학논문집, 한국강구조학회, 제25권, 제6호, pp.659-669. Kim, J.H., Kim, T.S., and Kang, H.S. (2013) Ultimate Strength Estimation of Ferritic Stainless Steel Single Shear Bolted Connections Fastened with Four Bolts, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.6, pp.659-669 (in Korean).
  6. Crawford, S.F. and Kulak, G.L. (1971) Eccentrically Loaded Bolted Connections, Journal of the Structural Division, ASCE, Vol.97, No.3, pp.765-783.
  7. Sato, A. and Uang, C.M. (2010) Seismic Performance Factors for Cold-Formed Steel Special Bolted Moment Frames, Journal of Structural Engineering, ASCE, Vol. 136, No.8, pp.961-967. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000191
  8. Uang, C.M., Sato, A., Hong, J.K., and Wood, K. (2010) Cyclic Testing and Modeling of Cold-Formed Steel Special Bolted Moment Frame Connections, Journal of Structural Engineering, ASCE, Vol.136, No.8, pp.953-960. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000190
  9. Hong, J.K. and Uang, C.M. (2004) Cyclic Testing of A Type of Cold-Formed Steel Moment Connections for Pre-Fabricated Mezzanines, Report No. TR-04/03, University of California.
  10. Wallaert, J.J. and Fisher, J.W. (1964) Shear Strength of High-Strength Bolts, Fritz Laboratory Repots No. 288.20, Lehigh University.
  11. AISC (2010) Specification for Structural Steel Buildings, American Institute of Steel Construction, Inc., Chicago, Illinois, USA.
  12. 한국강구조학회(2009) 강구조기준에 따른 고력볼트 접합시공지침, 한국강구조학회. KSSC (2009) Fabrication Guide for Structural Joints Using High-Strength Bolts, Korean Society of Steel Construction (in Korean).

Cited by

  1. 단일볼트 지압접합부의 힘-변형관계 vol.29, pp.5, 2015, https://doi.org/10.7781/kjoss.2017.29.5.341