DOI QR코드

DOI QR Code

Multi-point detection of hydrogen using the hetero-core structured optical fiber hydrogen tip sensors and Pseudorandom Noise code correlation reflectometry

  • Received : 2015.01.07
  • Accepted : 2015.04.10
  • Published : 2015.06.30

Abstract

In this paper, the multi-point hydrogen detection system based on the combination of the hetero-core optical fiber SPR hydrogen tip sensor and interrogator by pseudorandom noise (PN) code correlation reflectometry has been developed. In a light intensity-based experiment with an LED operating at 850 nm, it has been presented that a transmitted loss change of 0.32dB was induced with a response time of 25 s for 4% $H_2$ in $N_2$ in the case of the 25-nm Au, 60-nm $Ta_2O_5$, and 5-nm Pd multi-layers film. The proposed sensor characteristic shows excellent reproducibility in terms of loss level and time response for the in- and out- $H_2$ action. In addition, in the experiment for multi-point hydrogen detection, all sensors show the real-time response for 4% hydrogen adding with reproducible working. As a result, the real-time multi-point hydrogen detection could be realized by means of the combination of interrogating system and hetero-core optical fiber SPR hydrogen tip sensors.

Keywords

References

  1. J. Villatoro, D. Luna-Moreno, and D. Monzon-Hernandez, 2005, "Optical fiber hydrogen sensor for concentrations below the lower explosive limit," Sens. Actuators B 110, 23-27. https://doi.org/10.1016/j.snb.2005.01.009
  2. J. Villatoro, and D. Monzon-Hernandez, 2005, "Fast detection of hydrogen with nano fiber tapers coated with ultra thin palladium layers," Opt. Express Vol. 13, No. 13, pp. 5087-5092. https://doi.org/10.1364/OPEX.13.005087
  3. M. Tabib-Azar, B. Sutapun, R. Petrick, and A. Kazemi, 1999, "Highly sensitive hydrogen sensors using palladium coated fiber optics with exposed cores and evanescent field interactions," Sens. Actuators B 56, pp. 158-163. https://doi.org/10.1016/S0925-4005(99)00177-X
  4. C. L. Tien, H. W. Chen, W. F. Liu, S. S. Jyu, S. W. Lin, and Y. S. Lin, 2008, "Hydrogen sensor based on side-polished fiber Bragg gratings coated with thin palladium film," Thin Solid Films 516, pp. 5360-5363. https://doi.org/10.1016/j.tsf.2007.07.045
  5. A. Trouillet, E. Marin, and C. Veillas, 2006, "Fibre gratings for hydrogen sensing," Meas. Sci. Technol. Vol. 17, No. 5, pp. 1124-1128. https://doi.org/10.1088/0957-0233/17/5/S31
  6. S. Sumida, S. Okazaki, S. Asakura, H. Nakagawa, H. Murayama, and T. Hasegawa, 2005, "Distributed hydrogen determination with fiber-optic sensor", Sens. Actuators B 108, 508-514. https://doi.org/10.1016/j.snb.2004.11.068
  7. A. Hosoki, M. Nishiyama, H. Igawa, A. Seki, Y. Choi, and K. Watanabe, 2013, "A surface plasmon resonance hydrogen sensor using Au / $Ta_2O_5$/ Pd multi-layers on hetero-core optical fiber structures", Sens. Actuators B 185, pp. 53-58. https://doi.org/10.1016/j.snb.2013.04.072
  8. M. Iga, A. Seki, and K. Watanabe, 2005, "Gold thickness dependence of SPR-based hetero-core structured optical fiber sensor," Sens. Actuators B 106, pp. 363-368. https://doi.org/10.1016/j.snb.2004.08.017
  9. K. Takagi, and K. Watanabe, 2012, "Near Infrared Characterization of Hetero-Core Optical Fiber SPR Sensors Coated with $Ta_2O_5$ Film and Their Applications," Sensors 12, pp. 2208-2218. https://doi.org/10.3390/s120202208
  10. S. Onoda, K. Inoue, T. Nakata, O. Yumoto, and N. Tsukamoto, 2006, "Detection of Rayleigh Back Scattering by Pseudorandom Noise code Correlation Reflectometry," IEICE general conference, C-5-12.