Abstract

High-power semiconductor devices and microprocessors in factory electrical installation so sensitive to power quality measurements such as harmonic currents, voltage fluctuations, flicker, current imbalance. Therefore, the little change of power quality can influences the productivity of factory electrical machines. Troubleshooting these problems requires accurate measurements and analysis of power quality with monitoring instruments that can effectively locate issues and identify solutions. In this paper, the author presents hand-held power quality monitoring system to locate issues and identify solutions. The proposed system consists of two parts, One is to develop hand-held power meters by using NI(National Instrument) DAQ(Data Acquisition) and WLAN. Another is develop power quality monitoring MMI(Man-Machine Interface) using LabView software. To demonstrate the validity of the proposed algorithm, variable tests are carried out.

본 연구에서는 휴대용 계측기기를 이용한 공장 수용가 전력품질 분석시스템을 제시한다. 기존의 전력품질 분석시스템은 주로 대규모 공장 수용가에서 상시 연결 되어, 공장 전력 데이터를 연속적으로 취득, 저장한 후 분석까지 수행하고 있다. 그러나 이러한 시스템의 문제점은 데이터 취득을 위해 설치된 미터에서 수집된 Raw 데이터를 이용하여 공장 수용가의 전체적인 전력 품질을 감시 할 수는 있으나, 비선형 부하의 조합으로 인한 전력품질 저하 발생 시에는 그러한 상황에 대한 구체적인 원인을 파악하는 것은 불가능하다. 따라서 본 연구에서는 공장의 전력품질 저하가 발생되는 경우 의심되는 여러 부하의 전압, 전류를 직접 측정하여 그 원인이 되는 지점을 쉽게 찾아내고 그에 상응하는 조치가 가능하도록, 휴대용 계측기기 기반 공장 수용가 전력품질 분석시스템을 제시함으로써 보다 안정적인 공장 전력 부하 운영이 가능하도록 한다.

Keywords

References

  1. Y. I. Kim, S. J. Bang, J. H. Han, T. Y. Yun "Development of Power Quality Monitoring System(PQMS) : Datebase design for PQMS" KIEE summer conference 2003, Vol 1, pp. 28-130, Nov. 2003.
  2. Y. I. Kim, S. J. Bang, J. H. Han, T. Y. Yun "Development of Power Quality Monitoring System(PQMS) : Object-Oriented Design for Power Quality Analysis Software", KIEE summer conference 2003, Vol 1, pp. 131-133, Nov. 2003.
  3. S. J. Bang, Y. I. Kim, J. H. Han, T. Y. Yun "Development of Power Quality Monitoring System", KIEE summer conference 2003, Vol 1, pp. 158-160, Nov. 2003.
  4. Y. G. Jung, W. Y. Kim, J. Y. Cho, Y. C. Lim "A DSP based Three Phase Power Quality Analyzer", Transactions of Korean Institute of Power Electronics, Vol 6, pp. 362-368, Aug. 2001.
  5. S. I. Lee, G. H. Cho "Power Quality Analysis and Failure Survey of Earth Leakage Breakers in Factory Electrical Installation", Transactions of Korean Institute of Power Electronics, Vol 13, pp.15-21 Feb. 2008.
  6. S. Y. Choi "A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database", Journal of The Institute of Internet, Broadcasting and Communication(JIIBC), Vol.12, No. 4, pp.189-194, Aug. 2012. https://doi.org/10.7236/JIWIT.2012.12.4.189
  7. Y. S. Im, E. Y. Kang, "MPEG-2 Video Watermarking in Quantized DCT Domain," The Journal of The Institute of Internet, Broadcasting and Communication(JIIBC), Vol. 11, No. 1, pp. 81-86, 2011.
  8. I. Jeon, S. Kang, H. Yang, "Development of Security Quality Evaluate Basis and Measurement of Intrusion Prevention System," Journal of the Korea Academia-Industrial cooperation Society(JKAIS), Vol. 11, No. 1, pp. 81-86, 2010.