Abstract

The new types of phosphazene diagnostic membranes have been prepared for blood glucose measurements. The possible interferents in human blood were sorted into 4 different series and their effects on the glucose measurements were examined. In case of series I which indicates the lowest concentration, most of them did not show any serious effects on the blood glucose measurements, but only ascorbic acid (AA) showed 5~8% higher values compared to K/S values of the standard solution. In case of series II, all of four interferents showed 3~4% lower K/S values than those of plasma, but they showed consistent values by concentration variation. In case of series III, all of three interferents did not show any big differences compared to the standard solution. In case of series IV which indicates the highest concentration, two interferents showed 11~15% lower K/S values than the standard values, however they did not any serious effect on the blood glucose measurements.

새로운 형태의 포스파젠 진단막을 제조해 혈액 속의 글루코우즈의 농도를 측정하였다. 혈액 속에 존재할 가능성이 높은 장애성분들을 4가지 그룹으로 분류하여 혈당 측정에 미치는 영향을 조사하였다. 가장 낮은 농도를 나타내는 시리즈 I의 경우, 대부분의 첨가물들이 혈당 측정에 큰 영향을 미치지 않았으나, 오직 ascorbic acid (AA)만이 기준 용액보다 5~8% 정도 높은 K/S 결과치를 나타내었다. 시리즈 II의 경우, 네 가지 첨가물 모두 기준 용액의 K/S 결과치보다 3~4% 다소 낮은 값을 보였으나 농도에 따른 일정한 값을 보여 주었다. 시리즈 III의 경우, 세 가지 첨가물 모두 기준 용액에서 얻어지는 K/S 결과치와 큰 차이를 보이지 않았다. 가장 높은 농도를 나타내는 시리즈 IV의 경우, 두 가지 물질 모두가 기준 값보다 11~15% 정도 낮은 수치를 나타내었으나 혈당 측정에 크게 영향을 주지는 않았다.

Keywords

References

  1. Y. Cho, "Diabetes, as much as know that look", Miraejysik, Seoul (2006).
  2. Home Health Management Research Institute, "Diabetes", Kumyoung, Seoul (1992).
  3. Seoul National University Hospital, "A guide for diabetes management", Bummoon education, Seoul (2012).
  4. Y. Kim, "Diabetes treatment", Medbook, Seoul (2012).
  5. T. Asano and T. Norioka, "Diabetes", Nihon Bungeisha, Tokyo (2000).
  6. K. Huh, "Diabetic health", D and C Media, Seoul (2006).
  7. S. Kim, "Life guide for diabetes control", Hyoseong, Seoul (1993).
  8. T. Asano, "Diabetic food and life style", Shufu-To-Seikatsusha Co., Tokyo (2005).
  9. J. Kim, "Diabetes: Diagnostics and control", Ohsung, Seoul (1997).
  10. S. Kwon and M. Choi, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (2): Effects of blood constituens on the measurements of glucose concentration", Membr. J., 18, 4 (2008).
  11. S. Kwon and J. Yu, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (3): Effects of storage environments on the measurements of glucose concentration", Membr. J., 19, 3 (2009).
  12. S. Kwon, "Preparation of polyurethane diagnostic membranes for blood glucose measurements (6): Effects of hematocrit on the measurements of glucose concentration", Membr. J., 20, 3 (2010).
  13. S. Kwon, "Studies on the polyurethane diagnostic membrane for diabetes (2): Effects of additives in membrane formulations for the measurement of urine glucose", Polymer (Korea), 18, 6 (1994).
  14. S. Kwon, I. Park, and D. Yoon, "The preparation of polyacrylonitrile diagonostic membranes for blood glucose measurements (1): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 4 (2007).
  15. R. P. Back, "Biosensor technology", Marcel Dekker, New York (1990).
  16. S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (2): Effects of temperature on the measurements of glucose concentration", Hongik Industrial Technology, 13, 551 (2003).
  17. R. E. Kesting, "Synthetic polymeric membranes", Wiley-Interscience, New York (1985).
  18. M. Gordon, "Polymer membranes", Springer-Verlag, New York (1985).
  19. S. Kwon, "Basic studies on the preparation of diagnostic membranes by using multi-layered gelatin films to measure blood glucose level of diabetics", Membr. J., 8, 1 (1998).
  20. S. Kwon, "Studies on the muti-layered gelatin diagnostic membranes for diabetes (2): Effects of interferents in blood on the diffusion-controlled rates of glucose", Membr. J., 9, 4 (1999).
  21. S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (1): Model experiments by using microporous polyurethane membrane", Hongik Industrial Technology, 12, 717 (2002).
  22. S. Kwon, "A study on the preparation of polyurethane diagnostic membrane for urine glucose test", J. Kor. Ind. & Eng. Chem., 5, 6 (1994).
  23. S. Kwon, I. Park, and D. Yoon, "Studies on the preparation of polyurethane diagnostic membranes for blood glucose measurements (5): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 1 (2007).
  24. S. Kwon and C. Jun, "Studies on polyphosphazenes- bound Wittig reactions", J. of Korean Ind. & Eng. Chem., 5, 5 (1994).
  25. H. R. Allcock, M. Gebura, S. Kwon, and T. X. Neenan, "Amphiphilic polyphosphazenes as membrane materials: Influence of side group on radiation crosslinking, semipermeability, and surface morphology", Biomaterials, 9, 500 (1988). https://doi.org/10.1016/0142-9612(88)90045-2
  26. H. R. Allcock and S. Kwon, "Hydrophilic polyphosphazenes as hydrogels: Radiation crosslinking and hydrogel characteristics of poly[bis(methoxyethoxy) phosphazene]", Biomaterials, 7, 6 (1986).
  27. S. Kwon and B. Lee, "A study on the preparation of metal-ion separation membrane with hydrophilic polyphosphazene", J. of Korean Ind. & Eng. Chem., 10, 3 (1999).
  28. S. Kwon and B. Lee, "A Study on the preparation of ion-exchange membranes with polyphosphazenes", J. of Korean Ind. & Eng. Chem., 9, 3 (1998).
  29. S. Kwon, "Effects of testing and storage environments on the blood glucose measurements by using phosphazene diagnostic membranes", Membr. J., 22, 5 (2012).
  30. S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using polyphosphazene diagnostic membranes" Membr. J., 23, 4 (2013).
  31. S. Kwon, "Preparation of phenoxy-methylamino cosubstituted polyphosphazene diagnostic membranes for bllod glucose measurement", Membr.J., 24, 4 (2014).
  32. H. R. Allcock and S. Kwon, "Covalent linkages of proteins to surface-modified poly(organophosphazenes): Immobilization of glucose-6-phosphate dehydrogenase and trypsin", Macromolecules, 19, 1502 (1986). https://doi.org/10.1021/ma00160a002