A Verification Study on the Temperature reduction Effect of Water Mist Injection

  • Received : 2015.03.13
  • Accepted : 2015.06.15
  • Published : 2015.06.30

Abstract

Purpose: Recently, according to climate changes, human health is exposed to danger over the world and they influence all fields of human society. Due to these climate changes, humans can be exposed to more frequent and extreme scorching heat and cold wave than the present. As precautions against these urban higher temperature and dryness, diverse methods are being sought. Among them, as measures to form cold islands, the evaporative cooling effect realistic to social and economic conditions was examined. Method: This study was conducted to analyze effects of temperature reduction and cooling according to injection quantity of minute water particles by using a blast sprayer as one of alternatives of alleviation of urban climate changes in outside space in summer. For this, through temperature difference in accordance with the injection quantity per hour of a day, a time zone representing the value of the highest temperature change was analyzed. Also, by analyzing temperature difference according to the injection quantity per daytime insolation, relation of amounts of insolation and evaporation was investigated. Temperature difference in accordance with distances at the highest temperature with the highest value in temperature changes was analyzed. Result: At the study result, about temperature, as injection quantity increase, temperature reduction was significant statistically at the highest temperature with the most insolation. A factor with the highest influence was judged to be the increase of the injection quantity. According to the injection quantity, it was predicted that $3.1^{\circ}C$ temperature reduction of a daily average in case of 0.16L/min, $3.5^{\circ}C$ temperature reduction of a daily average in case of 0.32L/min, and $4.4^{\circ}C$ temperature reduction of a daily average in case of 0.48L/min.

Keywords

References

  1. G. Yoon et al. "Study on cooling system by using dry mist-validation of cooling effectiveness and CFD simulation", Environ Eng, 2008, Vol. 73, No. 633, pp13-20
  2. G. Yoon and M. Okumiya "Cool spot in urban area Dry Mist system-", Proceeding of The Society of Heating, Air-Conditioning and Sanitary Enginners of Japan, 2009, Vol. 83, No. 8, pp651-657
  3. Gyuyoung Yoon. Hideki Yamada nad Masaya Okumiya, Study on cooling system with Using Water Mist control Stratagy for Water Mist system Renew able Energy, 2010, Vol. 22, pp25-29
  4. 홍기배, "Water Mist를 이용한 Cooling System의 특성에 관한 연구: 한 개의 노즐에 대한 실험을 중심으로" 한국교통대학교 2013 논문집, 제 48권 pp27-32 // (Hong Ki-Bea, A Study on the characteristics of cooling system using water Mist, Korea National University of Transportation Journal, 2013, Vol. 48, pp27-32)
  5. 박사근, 신훈, 송민정, 장길수, "미세물분무의 냉각효과에 관한 실험적 연구", 대한건축학회 2005 학술발표대회 논문집, 제 25권 제1호, pp223-226 // (Park Sa-Keun, Shin Hoon, An Experimental Study on Cooling Effect of Water Mist Spray, Journal of Architectural Institute of Korea, 2005, Vol. 25, No. 1, pp223-226)
  6. 김기덕, 이응호, 김원배, 이준구, "곤달비 여름재배시 냉각방법과 냉수호스 베드재배가 생육 및 미기상에 미치는 영향", 한국생물환경조절학회 학술발표 논문집 2011 제 20권 제2호 pp116-122 // (Kim Ki-Deog, Lee Eung-Ho, Kim Won-Bae, Lee Jun-Gu, Effects of Several Cooling Methods and Cool Water Hose Bed Culture on Growth And Microclimate in Summer Season Cultivation of Narrowhead Goldenray, Journal of Bio-Environment Control, 2011, Vol. 20, No. 2, pp116-122)
  7. 김영찬, "초음파진동을 이용한 미세분무냉각 열전달에 관한 실험적 연구", 한국액체미립화학학회지 2010 제 15권 제4호 pp 202-207 // (Kim Yeung-Chan, The Experimental Study on Mist Cooling Heat Transfer, Journal of Ilass Korea, 2010, Vol. 15, No. 4, pp202-207)
  8. 강정윤, 최동호, 임홍성, 허종철, "미스트 분무 및 스프링클러 관수가 단동 플라스틱 하우스에 미치는 냉각효과", 제주대학교 산업기술연구소 학술저널, 2000 제 11권 제2호 pp1-12 // (Kang Jeong-Yun, Choi Dong-Ho, Im Hong-Sung, Huh Jong-Chul, A Study on Cooling Effects of Spray Mist or Sprinkler on Single Span Plastic Greenhouses, Journal of Research Institute Of Advanced Technology, 2000, Vol. 11, No. 2, pp1-12)
  9. 이현우, 김영식, "상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용", 한국생물환경조절학회 학술발표 논문집 2011 제 20권 제1호. pp1-7 // (Lee Hyun-Woo, Kim Young-Shik, Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling, Journal of Protected Horticulture and Plant Factory, 2011, Vol. 20, No. 1, pp1-7)
  10. 허종철, 최동호, 임종환, 서효덕, "미스트 분무시간 및 휴지시간 변화에 따른 하우스 냉각효과 검토", 한국생물환경조절학회 학술발표 논문집 1999 제 8권 제2호 pp59-62 // (Huh Jong-Chul, Choi Dong-Ho, Im Jong-Hyan, Suh Hyu-Duk, Evaluation of Cooling Effects in Greenhouses with Mist System at Variations of Spraying or Non-spraying Time Durations, Journal of Protected Horticulture and Plant Factory, 1999, Vol. 8, No. 2, pp59-62)
  11. 주창훈, 김정호, 윤용한, "도시 열환경을 고려한 녹지관리방안 수립 연구", 한국환경과학회지 2014 제 23권 제7호 pp1349-1358 // (Joo Chang-Hun, Kim Jeong-Ho, Yoon Yong-Han, A Study on Green Space Management Planning Considering Urban Thermal Environment, Journal of Environmental Science International, 2014, Vol. 23, No. 7, pp1349-1358)

Cited by

  1. Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change vol.27, pp.12, 2018, https://doi.org/10.5322/JESI.2018.27.12.1261