DOI QR코드

DOI QR Code

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter

동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구

  • Ryu, Ri (Dept. of Architectural Design, Graduate School of Techno Design, Kookmin University) ;
  • Seo, Jang-hoo (Dept. of Architectural Design, School of Architecture / Graduate School of Techno Design, Kookmin University) ;
  • Kim, Yong-seong (Dept. of Architectural Design, Graduate School of Techno Design, Kookmin University)
  • Received : 2015.04.07
  • Accepted : 2015.05.19
  • Published : 2015.06.30

Abstract

Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

Keywords

References

  1. 국토교통통계누리 (http://stat.molit.go.kr),주택보급률(Housing Supply Ratio), 승인번호 제11628호 // (www.stat.molit.go.kr, MOLIT-Related Statistics, Housing Supply Ratio, Approval No. 11628)
  2. 류리, 지충구, 김용성, "PCM을 적용한 창호형 이중외피 시스템 연구", 대한건축 학회지(학술논문),제29권 제4호 통권 제294호, pp.227-234, 2013.04 // (Ri Ryu, Chung-gu Ji, Young-Seong Kim, A Study of Window-Type Double Skin System Using PCM: Focusing on Energy Reduction for Heating and Cooling , Architectural Institute of Korea, Vol. 29 No. 04, pp.227-234, 2013.04)
  3. 이규영, 류리, 서장후, 김용성, "냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구", 대한건축설비공학회 논문집, Vol. 26 No. 06, pp.247-256, 2014.06 // (Kyuyoung Lee, Ri Ryu, Janghoo Seo, Yongseong Kim , Study on PCM applied Thermal Storage Wall System to reduce Cooling Energy, Korean Journal of Air-Conditioning and Refrigeration Engineering , Vol. 26 No. 06, pp.247-256, 2014.06)
  4. 이건호, 김현수, 장대희, 문수영, "다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구", 한국생태환경건축학회 논문집(학술논문), Vol. 5 No. 2, pp 19-26, 2005 // (Lee Keon-ho, Kim Hyeon-soo, Jang Dae-hee, Moon Soo-young, Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions, Vol. 5 No. 2, pp 19-26, 2005)
  5. 오정익, "Huri Focus : 기후변화대응 축열 건자재의 개발 동향 제 36호", 주택도시 연구원, 2009 // (Oh, Jung-gik, Huri Focus : Climate change, the development trend of building materials corresponding regenerative, House and City Research Institute, 2009)
  6. Ri Ryu, Chung-gu Ji, Janghoo Seo, Young-Seong Kim, A study on the analysis of indoor temperature according to the PCM temperature applied to the double skin facade system for saving cooling energy during summer season, Contemporary Engineering Sciences, 2014

Cited by

  1. 에어캡 적층을 통한 에어캡 벽 모듈 개발 vol.29, pp.10, 2017, https://doi.org/10.6110/kjacr.2017.29.10.504
  2. Performance Evaluation of the Louver-type Double-skin Facade System using PCM Film for Cooling Energy Reduction vol.20, pp.2, 2020, https://doi.org/10.12813/kieae.2020.20.2.015