DOI QR코드

DOI QR Code

Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship

선박 복합 밀폐공간 내 환기효율 분석을 통한 공기환경 개선에 관한 연구

  • Jeong, Jae-Hoon (Department of Global Construction Engineering, Sungkyunkwan University) ;
  • Song, Doosam (Department of Architectural Engineering, Sungkyunkwan University)
  • 정재훈 (성균관대학교 글로벌건설엔지니어링학과) ;
  • 송두삼 (성균관대학교 건축공학과)
  • Received : 2015.04.23
  • Accepted : 2015.07.21
  • Published : 2015.08.10

Abstract

In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied.

Keywords

References

  1. Paik, E. G., 2004, The Study on Improvement of Industrial Ventilation Efficiency Forced on Welding Process of Shipbuilding, Proceedings of the Occupational Safety and Health Research Institute.
  2. Seo, J. M., Rho, J. H., and Han, M. S., 2014, Study on Airflow Analyses of Confined Spaces in Ship Structures Using Network Simulation, Proceedings of the SAREK, pp. 519-522.
  3. Moon, J. H., Cho, D. H, Kang, S. Y., Choi, C. H., Im, Y. C., and Lee, J. H., 2005, Improvement of Indoor Air Environment in a Large Welding Factory by Displacement Ventilation, Proceedings of the SAREK, pp. 69-74.
  4. Ha, H. C., Kim. T. H., Choi, M. R., and Park, S. C., 2007, A study on applicability of exposure standard and improvement of work envirnment for reducing welding fume(Mn) exposure in shipbuilding industry, Proceedings of the Occupational Safety and Health Research Institute.
  5. Jeong, J. H., Seo, J. M., Roh, J. H., and Song, D. S., 2014, Study on Improvement of Air Quality under the Welding in Complex Enclosures of Ship, Proceedings of the SAREK, pp. 87-90.
  6. Lee, K. M. and Lee, C, G., 2007, A study on the effect of welding fume during the welding work, Proceedings of the KWJS, pp. 306-309.
  7. Sim, G. J., 2000, Control method of welding fume in $CO_2$, Proceedings of the SAREK, pp. 1-16.
  8. Park, J. W., 2005, The state of the art of Japaness ventilation standard, Proceedings of the SAREK, pp. 104-115.
  9. Kato, S. and Murakami, S., 1988, New ventilation efficiency scales based on spatial distribution of contaminant concentration aided by numerical simulation, ASHRAE Transaction, Vol. 94, No. 2, pp. 309-30.
  10. Murakami, S., 1992, New scales for ventilation efficiency and their application based on numerical simulation of room airflow, Proceedings of the ISRACVE, ASHRAE, pp. 29-40.
  11. Kato, S. and Murakami, S., 1992, New scales for evaluating ventilation efficiency as affected by supply and exhaust openings based on spatial distribution of contaminant, Proceedings of the ISRACVE, ASHRAE, pp. 177-186.

Cited by

  1. Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 vol.28, pp.6, 2016, https://doi.org/10.6110/KJACR.2016.28.6.256