DOI QR코드

DOI QR Code

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery

시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가

  • Kwon, Ki Nam (Dept. of Optometry, Seoul National University of Science & Technology) ;
  • Kim, So Ra (Dept. of Optometry, Seoul National University of Science & Technology) ;
  • Park, Mijung (Dept. of Optometry, Seoul National University of Science & Technology)
  • 권기남 (서울과학기술대학교 안경광학과) ;
  • 김소라 (서울과학기술대학교 안경광학과) ;
  • 박미정 (서울과학기술대학교 안경광학과)
  • Received : 2015.08.03
  • Accepted : 2015.09.07
  • Published : 2015.09.30

Abstract

Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

목적: 본 연구에서는 써클콘택트렌즈의 착용이 시력교정술을 받은 눈에서 시력의 질에 어떠한 영향을 미치는 알아보고자 하였다. 방법: 시력교정술을 받지 않은 40안과 시력교정술을 받은 30안에 무도수의 써클콘택트렌즈를 각각 착용시키고 optical quality analysis system을 이용하여 변조전달기능(modulation transfer function, MTF), 객관적 산란지수(objective scatter index, OSI) 및 망막에 맺히는 상의 집속률(Strehl ratio)을 측정하여 객관적인 시력의 질 평가를 실시하였으며, 동공크기를 측정하여 객관적인 시력 질과 동공크기의 상관관계를 분석하였다. 결과: 시력교정술을 받은 눈에 써클콘택트렌즈를 착용하였을 경우는 시력교정술을 받지 않은 눈과 비교하여 모두 통계적으로 유의한 수준으로 변조전달기능이 더 저하되었고, 객관적 산란지수는 더 증가하였으며, 망막에 맺히는 상의 집속률은 더 감소하였다. 또한, 시력교정술을 받은 눈에서의 써클콘택트렌즈의 착용은 시력교정술을 받지 않은 사람에 비하여 동공크기에 따른 변조전달기능, 객관적 산란지수, 망막에 맺히는 상 집속률의 증감에 미치는 상관관계에 더 크게 영향을 미치는 것을 알 수 있었다. 결론: 본 연구에서 시력교정술 후 써클콘택트렌즈 착용은 실제 망막에 맺히는 상의 질에 근거한 객관적인 시력의 질을 저하시키는 것으로 나타났으므로 시력교정술을 한 경우에는 써클콘택트렌즈 착용하였을 때 시력의 질 저하에 대한 충분한 이해와 고려가 필요함을 제안한다.

Keywords

References

  1. Choi HJ, Yum JH, Lee JH, Lee DH, Kim JH. Clinical features and compliance in patients with cosmetic contact lens-related complications. J Korean Ophthalmol Soc. 2014;55(10):1445-1451. https://doi.org/10.3341/jkos.2014.55.10.1445
  2. Kim JH, Song JS, Hyon JY, Chung SG, Kim TJ. A survey of contact lens-related complications in Korea: the Korean contact lens study society. J Korean Ophthalmol Soc. 2014;55(1):20-31. https://doi.org/10.3341/jkos.2014.55.1.20
  3. Kim SR, Choi JH, Lee KG, Park M. Changes in the covering of pupil and the visual acuity by the illuminance when wearing circle soft contact lens. J Korean Ophthalmic Ophthalmol Soc. 2013;18(1):19-25. https://doi.org/10.14479/jkoos.2013.18.1.019
  4. Lee SW, Choi TH, Lee HB. Comparison of wavefront guided customized ablation vs conventional ablation. J Korean Ophthalmol Soc. 2003;44(11):2607-2614.
  5. Oh JR, Kim JS, Lee DH. The change of ocular aberration after lasik surgery. J Korean Ophthalmol Soc. 2003;44(2): 278-283.
  6. Gobbe M, Reinstein DZ, Archer TJ. LASIK-induced aberrations: comparing corneal and whole-eye measurements. Optom Vis Sci. 2015;92(4):447-455. https://doi.org/10.1097/OPX.0000000000000557
  7. Beak JS, Park JH, Yoo ES, Kwon YA, Song WS, Kim BY, et al. Comparison of colvardpupillometer, ORBScan II and sirius in determining pupil size for refractive surgery. J Korean Ophthalmol Soc. 2013;54(8):1175-1179. https://doi.org/10.3341/jkos.2013.54.8.1175
  8. Kim MJ, Kim SK, Oh JH. The study on healing of the corneal epithelial cell in laser assisted subepithelial keratectomy( LASEK) on rabbits. J Korean Ophthalmol Soc. 2003;44(1):174-184.
  9. Chun YS, Lee JH, Lee JM, Jwa WB, Hong SJ, Lee YH, et al. Outcomes after implantable contact lens for moderate to hing myopia. J Korean Ophthalmol Soc. 2004; 45(3):480-489.
  10. Yvon C, Archer TJ, Gobbe M, Reinstein DZ. Comparison of higher-order aberration induction between manual microkeratome and femtosecond laser flap creation. J Refract Surg. 2015;31(2):130-135. https://doi.org/10.3928/1081597X-20150122-09
  11. Kamiya K, Shimizu K, Igarashi A, Kobashi H, Ishii R, Sato N. Clinical evaluation of optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation. Invest Ophthalmol Vis Sci. 2012;53(6): 3161-3166. https://doi.org/10.1167/iovs.12-9650
  12. Martnez-Roda JA, Vilaseca M, Ondategui JC, Giner A, Burgos FJ, Cardona G, et al. Optical quality and intraocular scattering in a healthy young population. Clin Exp Optom. 2011;94(2):223-229. https://doi.org/10.1111/j.1444-0938.2010.00535.x
  13. Lee K, Ahn JM, Kim EK, Kim TI. Comparison of optical quality parameters and ocular aberrations after wavefrontguided laser in-situ keratomileusis versus wavefrontguided laser epithelial keratomileusis for myopia. Graefes Arch Clin Exp Ophthalmol. 2013;251(9):2163-2169. https://doi.org/10.1007/s00417-013-2356-x
  14. Kwak AY, Choi MJ, Seo KY, Ahn JM. Comparison of optical quality between two intraocular lenses using double- pass based optical quality analysis system. J Korean Ophthalmol Soc. 2013;54(12):1818-1823. https://doi.org/10.3341/jkos.2013.54.12.1818
  15. Martnez-Roda JA, Vilaseca M, Ondategui JC, Giner A, Burgos FJ, Cardona G, et al. Optical quality and intraocular scattering in a healthy young population. Clin Exp Optom. 2011;94(2):223-229. https://doi.org/10.1111/j.1444-0938.2010.00535.x
  16. Kim JY, Lee KJ. Evaluation of visual performance for implanted aspheric multifocal intraocular lens in the cataract patients. J Korean Ophthalmic Opt Soc. 2013;18(3): 347-356. https://doi.org/10.14479/jkoos.2013.18.3.347
  17. Kamiya K, Shimizu K, Igarashi A, Kobashi H, Ishii R, Sato N. Clinical evaluation of optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation. Invest Ophthalmol Vis Sci. 2012;53(6): 3161-3166. https://doi.org/10.1167/iovs.12-9650
  18. Ko BU, Ryu WY, Park WC. Pupil size in the normal Korean population according to age and illuminance. J Korean Ophthalmol Soc. 2011;52(4):401-406. https://doi.org/10.3341/jkos.2011.52.4.401

Cited by

  1. The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery vol.21, pp.1, 2016, https://doi.org/10.14479/jkoos.2016.21.1.23
  2. Evaluation of Visual Function under Mesopic Conditions in Individuals Wearing Cosmetic Soft Contact Lenses vol.23, pp.4, 2018, https://doi.org/10.14479/jkoos.2018.23.4.351
  3. A Study on Contact Lens Wear Status of After Corneal Refractive Surgery Subjects vol.19, pp.1, 2017, https://doi.org/10.17337/jmbi.2017.19.1.9
  4. Visual Quality According to Refractive Correction Methods vol.19, pp.2, 2017, https://doi.org/10.17337/jmbi.2017.19.2.167
  5. Comparison of Visual Acuity and Pupil Size when Wearing the Circle Contact Lens After Refractive Surgery Depend on Illumination vol.19, pp.4, 2015, https://doi.org/10.17337/jmbi.2017.19.4.551