DOI QR코드

DOI QR Code

Simulations of Finite Schematic Eyes for Presbyopia Using the Navarro Eye Model

Navarro 모형안을 이용한 노안 정밀모형안의 전산모사

  • Kim, Shin-Hwa (Dept. of Optometry, Seoul National University of Science and Technology) ;
  • Kim, Dal-Young (Dept. of Optometry, Seoul National University of Science and Technology)
  • 김신화 (서울과학기술대학교 안경광학과) ;
  • 김달영 (서울과학기술대학교 안경광학과)
  • Received : 2015.07.24
  • Accepted : 2015.09.07
  • Published : 2015.09.30

Abstract

Purpose: This study was aimed to design new schematic eyes for presbyopia using the Navarro eye model and clinical data. Methods: We collected clinical data of eye-optical parameters of males in their age of 40, 50, and 60 from previous studies, and designed schematic eyes for presbyopia using the ZEMAX program. Results: The presbyopic process and features of the designed schematic eyes well accorded with the clinical data of previous studies. Conclusions: On the basis of the Navarro eye model, a finite schematic eyes for presbyopia were newly designed corresponding with clinical data.

목적: 본 연구는 Navarro 정밀모형안을 이용하고 임상데이터를 적용시킨 새로운 노안 모형안을 전산모사하는 것을 목표로 하였다. 방법: 40세, 50세, 60세 남성을 대상으로 선행연구로부터 광학적 매개변수에 관한 임상데이터를 수집하고, ZEMAX 광학프로그램을 이용하여 노안 정밀모형안을 설계하였다. 결과: 설계된 노안 정밀모형안들의 노안 진행 과정과 특징들이 선행연구들의 임상데이터들과 잘 일치하였다. 결론: Navarro 모형안을 기반으로 하여 임상자료와 상응하는 노안 정밀모형안을 새롭게 설계할 수 있었다.

Keywords

References

  1. Kim BH, Kim SJ, Lim HS, Ji TS. Design of the schematic eye of Koreans using the clinical data. J Korean Ophthalmic Opt Soc. 2004;9(1):117-124.
  2. Kim SG, Park SC. Prediction of visual performance using contrast sensitivity function and modulation transfer function. J Korean Ophthalmic Opt Soc. 2004;15(5):461-468.
  3. Sturzu A, Luca-Motoc D. Theoretical eye models comparison based on MTF evolution. Bulletin of the Transilvania University of Brasov SeriesI: Engineering Sciences. 2011;4(53):33-38.
  4. Sung PJ. Optometry, 5th Ed. Seoul: Daihakseorim, 2005; 33-40.
  5. Kang EK, Park SC, Kim JJ, Hwangbo CK. Analysis and design of an accommodation-dependent eye model based on Navarro model. J Korean Ophthalmic Opt Soc. 2010; 15(3):235-240.
  6. Kim SG, Choi KU. Analysis of accommodation error at the Navarro eye. Korean J Vis Sci. 2007;9(1):43-51.
  7. Navarro R, Santamaria J, Bescos J. Accommodationdependent model of the human eye with aspherics. J Opt Soc Am A. 1985;2(8):1273-1281. https://doi.org/10.1364/JOSAA.2.001273
  8. Statistics Korea. The population ratio of the aged people and the aging index, 2015. http://kosis.kr/statHtml/statHtml.do?orgId=113&tblId=DT_113_STBL_1015552&vw_cd=MT_ZTITLE&list_id=113_11314_02&seqNo=&lang_mode=ko&language=kor&obj_var_id=&itm_id=&conn_path=E1(20 July 2015).
  9. Weale RA. Presbyopia. Brit J Ophthalmol. 1962;46:660-668. https://doi.org/10.1136/bjo.46.11.660
  10. Baarg SB. Optical models of the finite schematic eyes for presbyopia. J Korean Ophthalmic Opt Soc. 2008;19(6): 439-447.
  11. Dubbelman M, Weeber HA, van der Heijde RGL, Vlker-Dieben HJ. Radius and asphericity of the posterior corneal surface determined by corrected Scheimpglug photography. Acta Opthalmol Scand. 2002;80(4):379-383. https://doi.org/10.1034/j.1600-0420.2002.800406.x
  12. Dubbelman M, Sicam VA, Van der Heijde GL. The shape of the anterior and posterior surface of the aging human cornea. Vis Res. 2006;46(6):993-1001. https://doi.org/10.1016/j.visres.2005.09.021
  13. Atchison DA, Markwell EL, Kasthurirangan S, Pope JM, Smith G, Swann PG. Age-related changes in optical and biometric characteristics of emmetropic eyes. J Vis. 2008; 8(4):1-20.
  14. Dubbelman M, Van der Heijde GL. The shape of the aging human lens: curvature, equivalent refractive index and paradox. Vis Res. 2001:41(14);1867-1877. https://doi.org/10.1016/S0042-6989(01)00057-8
  15. Sivak JG, Mandelman T. Chromatic dispersion of the ocular media. Vis Res. 1982;22(8):997-1003. https://doi.org/10.1016/0042-6989(82)90036-0
  16. Wikpedia. CIE 1931 color space , 2015. https://en.wikipedia.org/wiki/CIE_1931_color_space(5 June 2015).
  17. Alessi PJ. CIE technical report calorimetry, 2004. https://www.google.co.kr/url?sa=t&rct=j&q=&esrc=s&source=web&cd=3&ved=0CCwQFjACahUKEwi0-qrAou7GAhUWW4gKHcuyD_o&url=http%3A%2F%2Fwww.cdvplus.cz%2Ffile%2F3-publikace-cie15-2004%2F&ei=e02vVfTQIpa2oQTL5b7QDw&usg=AFQjCNEJEKGrJDBpo7hVn0Z_T_AYs9a24Q&sig2=GhvSv1ylL02qYVOcXzBHVQ&bvm=bv.98197061,d.dGY(22 July 2015).
  18. International Organization for Standardization (ISO). Ophthalmic implants intraocular lenses - part 2: Optical properties and test methods, 2014. http://www.iso.org/iso/catalogue_detail.htm?csnumber=55682(22 July 2015).
  19. Kim SG, Park SC. Prediction of visual performance using contrast sensitivity function and modulation transfer function. J Korean Ophthalmic Opt Soc. 2004;15(5):461-468.
  20. Koretz JE, Strenk SA, Strenk LM, Semmlow JL. Scheimpflug and high-resolution magnetic resonance imaging of the anterior segment: A comparative study. J Opt Soc Am A Opt Image Sci Vis. 2004;21(3):346-354. https://doi.org/10.1364/JOSAA.21.000346
  21. Wong TY, Foster PJ, Ng TP, Tielsch JM, Johnson GJ, Seah SK. Variations in ocular biometry in an adult Chinese population in Singapore: The Tanjong Pagar Survey. Invest Ophthalmol Vis Sci. 2001;42(1):73-80.
  22. Glasser A, Campbell MC. Presbyopia and the optical changes in the human crystalline lens with age. Vis Res. 1998;38(2):209-229. https://doi.org/10.1016/S0042-6989(97)00102-8
  23. Cavallotti CAP, Cerulli A. Age-related changes of the human eye (Chap. 3. Aging effects on the optics of the eye written by Artal P.), 1st Ed. New York: Humana Press, 2008: 35-44.

Cited by

  1. A Simulation Study of Female Schematic Eyes for the Presbyopia Based on the Clinical Data vol.22, pp.1, 2017, https://doi.org/10.14479/jkoos.2017.22.1.41