Abstract

Purpose: This study was to find the correlation between exophthalmetry and visual functions. Methods: Exophthalmetry and visual functions of 200 adults without ophthalmophathy and general disease were examined. Exophthalmetry were measured with Hertel's exophthalmometer. Visual functions (myopia, distance exophoria, near exophoria, near point of convergence, near point of accommodation) were measured for three times. Results: The exophthalmetry was $13.59{\pm}1.10mm$. Myopia, distance exophoria, near exophoria, near point convergence, and near point accommodation were measured as $-2.48{\pm}1.91D$, $3.51{\pm}1.78{\Delta}$, $5.73{\pm}2.44{\Delta}$, $9.63{\pm}2.82cm$, and $21.73{\pm}10.28cm$. With increasing exophthalmetry, the unaided visual acuity, myopia and astigmatism were decreased. On the other hand, distance exophoria, distance esophoria, near exophoria, near point of convergence and near point of accommodation were significantly increased, while exophthalmetry was increased. Conclusions: The relationship between visual functions and exophthalmetry were found to be statistically significant. It could be used as the clinical criteria for prescription of binocular inspections.

목적: 안구돌출도와 시기능의 상관관계를 알아보고자 하였다. 방법: 안질환과 전신질환이 없는 성인 남녀 200명(20~50대 각 50명)을 대상으로 안구돌출도와 시기능을 검사하였다. 허텔 안구돌출계로 안구돌출도를 측정하였고, 근시, 외사위, 내사위, 폭주 근점, 조절 근점 등 시기능 요소에 대한 검사를 3회 반복하여 실시하였다. 결과: 안구돌출도는 $13.59{\pm}1.10mm$, 근시, 원거리 외사위, 근거리 외사위, 폭주 근점 그리고 조절 근점은 $-2.48{\pm}1.91D$, $3.51{\pm}1.78{\Delta}$, $5.73{\pm}2.44{\Delta}$, $9.63{\pm}2.82cm$, $21.73{\pm}10.28cm$로 나타났다. 안구돌출도가 증가할수록 나안시력, 근시 그리고 난시도는 유의하게 감소하였다. 반면 원거리 외사위, 원거리 내사위, 근거리 외사위, 폭주 근점 그리고 조절 근점은 안구돌출도가 증가할수록 유의하게 증가하였다. 결론: 시기능과 안구돌출도의 유의한 관계는 양안시 처방과 검사를 위한 임상적 기준이 될 수 있을 것으로 사료된다.

Keywords

References

  1. McLellan JS, Marcos S, Burns SA. Age-related changes in monochromatic wave aberrations of the human eye. Invest Ophthalmol Vis Sci. 2001;42(6):1390-1395.
  2. Sudasethya. Visual testing and analysis, 1st Ed. Seoul: ShinKwang, 1996;13-199.
  3. Hofstetter HW. A useful age-amplitude formula. Optom World. 1950;38(12):42-45.
  4. Goss DA. Clinical accommodation testing. Curr Opin Ophthalmol. 1992;3(1):78-82. https://doi.org/10.1097/00055735-199202000-00011
  5. Cho YR, Park HJ, Seo JK, Seong JS, Kim JM. The study of binocular function of college students. J Korean Ophthalmic Opt Soc. 2005;10(2):103-110.
  6. Kim HE, Lew H, Yun YS. Exophthalmometric values with hertel exophthalmometers in children. J Korean Ophthalmol Soc. 2009;50(3):336-339. https://doi.org/10.3341/jkos.2009.50.3.336
  7. Koo HM, Shin SG, Yoon IH, Won IG. A clinical study of cause of unilateral exophthalmos. J Korean Ophthalmol Soc. 1995;36(8):1384-1389.
  8. Sung PJ. Optometry, 6th Ed. Seoul: Daehakseolim. 2009;73-573.
  9. Kang HS. Ophthalmic Introduction, 6th Ed. Seoul: Shinkwang, 2011;97-413.
  10. Chung TM. The exophthalmometry extraorbital width and height of lid fissure of Koreans. J Korean Ophthalmol Soc. 1974;15(4):305-311.
  11. Barretto RL, Mathog RH. Orbital measurement in black and white populations. Laryngoscope. 1999;109(7):1051-1054. https://doi.org/10.1097/00005537-199907000-00007
  12. Doo HY, Sim SH, Choi SM, Jang JU, Jeong JH. A study on long distance heterophoria of college students by the difference of testing method. J Korean Vis Sci. 2011;13(1):43-49.
  13. Choi SM. A study about N.P.C. heterophoria and near convergence and divergence by amount of the refractive errors. J Korean Ophthalmol Soc. 2009;14(4):53-57.
  14. Kim JG, Park DW. Visual inspection and analysis, 1st Ed. Seoul: Shinkwang, 1996;33-196.
  15. Kwark YJ. Normal range of exophthalmos in Korea. J Korean Ophthalmol Soc. 1974;15(4):312-315.
  16. Kim DH, Kwok LS. The analysis of normal values on the ocular protrusion and height of palpebral fissure on women university students in Korean. J Korean Ophthalmic Opt Soc. 2005;10(2):139-144.
  17. Wang FM, Millman AL, Sidoti PA, Goldber RB. Ocular findings in treacher collins syndrome. Am J Ophthalmol Soc. 1990;110(3):280-286. https://doi.org/10.1016/S0002-9394(14)76345-7
  18. Kim KH, Moon HK, Noh HR. Correlation between age and visual performance. J Korean Vis Sci. 2014;16(3):301-310.
  19. Seo YW. A study of relationship between refractive error and unaided visual acuity. J Korean Vis Sci. 2000;2(1):7-16.
  20. Smith G. Angular diameter of defocus blur discs. Am J Optom Physiol Opt. 1982;59(11):885-889. https://doi.org/10.1097/00006324-198211000-00006
  21. Yeatts RP. Exophthalmometry. Ophthalmology. 1995;102(1):3-4. https://doi.org/10.1016/S0161-6420(95)31058-5
  22. Phillips RA. Changes in corneal astigmatism. Am J Optom Arch Am Acad Optom. 1952;29(7):379-380. https://doi.org/10.1097/00006324-195207000-00009
  23. Kang HS, Seo YW, Kang IS. Measurement of the phoria for Korean male and female adults by maddox rod method. J Korean Ophthalmic Opt Soc. 1996;1(2):77-84.
  24. Kim JD. Clinical optometry and visual dysfunction, 2nd Ed. Seoul: Shinkwang, 2007;121-294.
  25. Kim IS, Oh YS, Jang JU. The study of near addition for presbyopia in accordance with distance ..near phoria. J Korean Vis Sci. 2012;14(3):197-203.