Effective dose of cone-beam computed tomography for orthodontic analysis in pediatric patient

소아환자에서 교정분석을 위한 콘빔CT 촬영시 유효선량에 관한 연구

  • Kim, Eun-Kyung (Department of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University)
  • 김은경 (단국대학교 치과대학 구강악안면방사선학교실)
  • Received : 2015.06.15
  • Accepted : 2015.07.10
  • Published : 2015.08.01

Abstract

Objective: The objectives of this study were to measure pediatric organ and effective doses of cone-beam computed tomography (CBCT) for orthodontic analysis and to compare them to those of panoramic and lateral cephalometric radiography, the conventional radiography for orthodontic analysis. Materials and Methods: Alphard VEGA for CBCT, Planmeca Proline XC for panoramic radiography and Orthophos CD for cephalometric radiography were used for this study. Thermoluminescent dosimeter (TLD) chips were located at 24 anatomic sites of 10-year-old anthropomorphic phantom and exposed during CBCT (C-mode; $200{\times}179mm$ FOV), panoramic and lateral cephalometric radiographic procedures at the clinical exposure settings for 10-year-old patient. Pediatric organ and effective doses were measured and calculated using ICRP 2007 tissue weighting factors. Results: Effective doses of CBCT, panoramic radiography and lateral cephlometric radiography in pediatric clinical exposure settings were $292.5{\mu}Sv$, $19.3{\mu}Sv$, and $4.4{\mu}Sv$ respectively. The thyroid gland contributed most significantly to the effective dose in all the radiographic procedures. Conclusion: Effective dose of CBCT was about 12 times to conventional radiographic procedures for orthodontic analysis in pediatric patient. The use of CBCT for orthodontic analysis should be fully justified over conventional radiography and dose optimization to decrease thyroid dose is needed in pediatric patients.

Keywords

References

  1. Arai Y, Tammisalo E, Iwai K, Hashimoto K, Shinoda K. Development of a compact computed tomographic apparatus for dental use. Dentomaxillofac Radiol 1999;28:245-8. https://doi.org/10.1038/sj.dmfr.4600448
  2. Momin MA, Matsumoto K, Ejima K, Asaumi R, Kawai T, Arai V, Honda K, Yosue T. Correlation of mandibular impacted tooth and bone morphology determined by cone beam computed topography on a premise of third molar operation. Surg Radiol Anat 2012 Nov 13; doi:10.1007/s00276-012-1031-y.
  3. Patel S, Dawood A, Whaites E, Pitt Ford T. New dimensions in endodontic imaging: part 1. Conventional and alternative radiographic systems. Int Endod J 2009;42:447-62. https://doi.org/10.1111/j.1365-2591.2008.01530.x
  4. Silva MA, Wolf U, Heinicke F, Bumann A, Visser H, Hirsch E. Cone-beam computed tomography for routine orthodontic treatment planning: a radiation dose evaluation. Am J Orthod Dentofacial Orthop 2008;133:640.e1-5.
  5. Lofthag-Hansen, Grondal K, Ekestubbe A. Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks. Clin Implant Dent Relat Res 2009;11:246-55. https://doi.org/10.1111/j.1708-8208.2008.00114.x
  6. Radiation protection No. 172. Evidence based guidelines on cone beam CT for dental and maxillofacial radiology. [Internet]. Luxemburg: European commission; 2012 [cited 2015 May 30]. Available from: (http://ec.europa.eu/energy/en/radiation-protection-publications)
  7. Ludlow JB, Davis-Ludlow LE, Brooks SL, Howerton WB. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 2006;35:219-26. https://doi.org/10.1259/dmfr/14340323
  8. Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:106-14. https://doi.org/10.1016/j.tripleo.2008.03.018
  9. Roberts JA, Drage NA, Davies J, Thomas DW. Effective dose from cone beam CT examinations in dentistry. Br J Radiol 2009;82:35-40. https://doi.org/10.1259/bjr/31419627
  10. Loubele M, Bogaerts R, Van Dijck E, Pauwels R, Vanheusden S, Suetens P, Marchal G, Sanderink G, Jacobs R. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 2009;71:461-8. https://doi.org/10.1016/j.ejrad.2008.06.002
  11. 정기정, 한원정, 김은경. 3차원 안모분석을 위한 저선량 Multi-detector CT영상의 유효선량 및 화질평가. 대한구강악안면방사선학회지 2010;40:15-23.
  12. Qu XM, Li G, Ludlow JB, Zhang ZY, Ma XC. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:770-6. https://doi.org/10.1016/j.tripleo.2010.06.013
  13. Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K, The SEDENTEXCT Project Consortium. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 2012;81:267-71. https://doi.org/10.1016/j.ejrad.2010.11.028
  14. Jeong DK, Lee SC, Huh KH, Yi WJ, Heo MS, Lee SS, Choi SC. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT. Imaging Sci Dent 2012;42:65-70. https://doi.org/10.5624/isd.2012.42.2.65
  15. Kim DS, Rashsuren O, Kim EK. Conversion coeffidents for the estimation of effective dose in cone-beam CT. Imaging Sci Dent 2014;44:21-9. https://doi.org/10.5624/isd.2014.44.1.21
  16. Theodorakou C, A, Horner K, Pauwels R, Bogaerts R, Jacobs R. Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms. Br J Radiol 2012;85:153-60. https://doi.org/10.1259/bjr/19389412
  17. 한원정, 김종수. 상악 정중과잉치 진단을 위한 cone beam CT의 유효선량. 대한소아치과학회지 2012;39:273-9.
  18. Ludlow JB, Walker C. Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2013;144:802-17. https://doi.org/10.1016/j.ajodo.2013.07.013
  19. Najjar AA, Colosi D, Dauer LT, Prins R, Patchell G, Branets I, Goren AD, Faber RD. Comparison of adult and child radiation equivalent doses from 2 dental cone-beam computed tomography units. Am J Orthod Dentofacial Orthop 2013;143:784-92. https://doi.org/10.1016/j.ajodo.2013.01.013
  20. Ludlow KB, Timothy R, Walker C, Hunter R, Benavides E, Samuelson DB, Scheske MJ. Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol 2015;44:20140197. https://doi.org/10.1259/dmfr.20140197
  21. International Comission on Radiological Protection. The 2007 Recommendations of the International Comission on Radiological Protection. ICRP publication 103. Ann ICRP 37.Oxford. UK : Pergamon Press, 2007.
  22. Hidalgo A, Davis J, Horner K, Theodorakou C. Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom. Dentomaxillofac Radiol 2015;44:20140285. https://doi.org/10.1259/dmfr.20140285