The automation system uses PLC to monitor the manufacturing process status of the production product and processes the sensor information transmitted from the sensor. In this paper, we propose a remote surveillance system to monitor the status of control relay used in automation system. The proposed system consists of a control relay module, a one-chip processor module, a computer monitoring system, and a database system that inputs and manages the details of the control relay. The computer monitoring system is configured to monitor the operating condition and life time of the control relay. The database is configured so that the input date of the control relay can be input and corrected, and the operating state information of the control relay can be automatically printed. In the remote monitoring system, the failure status of the control relay is recognized in real time, and the time required for normal operation can be minimized by quickly replacing faulty parts.

자동화시스템은 PLC를 사용하여 생산제품의 제조 공정상태를 감시하고 센서에서 전달되는 센서정보를 처리한다. 본 연구에서는 자동화시스템에 사용되고 있는 제어용 계전기의 상태를 감시하는 원격감시시스템을 제안한다. 제안한 시스템은 제어 릴레이모듈, 원칩프로세서 모듈, 컴퓨터 모니터링시스템과 제어용 계전기의 내역을 입력하고 관리하는 데이터베이스시스템으로 구성한다. 컴퓨터 모니터링시스템은 제어용 계전기의 작동상태와 수명을 모터링할 수 있도록 구성하였고, 데이터베이스는 제어용 계전기의 투입 일자를 입력하고 수정이 가능하게 구성하였으며, 제어용 계전기의 작동상태의 정보를 자동으로 프린트할 수 있도록 구성하였다. 원격감시시스템에서 제어용 계전기의 고장상태를 실시간으로 파악하고, 고장부품을 신속하게 교체하여 정상가동에 소요되는 시간을 최소화할 수 있도록 하였다.

Keywords

References

  1. Y. I. Kwon, and I. S. Han,"Mechanical Life Prediction of a Relay by Accelerated Life Tests," in Proceedings of the Korean Reliability Society Conference, vol. 9, pp.75-82, June 2005.
  2. K. B. Lee, "Electrical Life Estimation of Electromagnetic Relays by Accelerated Test(ALT)," Master Thesis, Dept. of Safety Engineering Graduate School of Industry and Engineering, Seoul National University, Feb. 2010.
  3. S. H. Ji, S. H. Kim, S. W. Heo, and D. S. Rho, "Evaluation Algorithm for Coordination Protection Between Substation Relay and Recloser," in Proceedings of the Korea Academia-Industrial Cooperation Society Fall Conference, vol. 29, pp.17-20, 2011.
  4. C. K. Kim, I. K. Lee, and S. H. Cho, "Study for Failure Examples of Solenoid Valve, Relay and Idle Control Actuator in Liquid Petroleum Gas vehicle Engines," Journal of the Korean Institute of Gas, vol. 15, no. 3, pp.47-52, June 2011. https://doi.org/10.7842/kigas.2011.15.3.047
  5. KSC 4520, "Hinge Type Electronic Relay," Korean Standards Association, 1992.
  6. I. S. Han, "Mechanical Life Prediction of a Relay by Accelerated Life Tests," Master Thesis, Department of Industrial Engineering Graduate School, Chongju University, Feb. 2004.
  7. Y. H. Chang and J. H Nam, "Implementation of Diagnostic Monitoring System for Auxiliary Relay," in Conference on Korea Information and Communication Engineering, vol. 20, no. 2, pp.709-711, 2016.