Abstract

Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

Keywords

References

  1. 국토교통부, "건축물의 설비기준 등에 관한 규칙", 국토교통부령 제 219호
  2. 김상민, 박병윤, 손장열, "공동주택 열교환기의 성능 및 에너지소비 특성 평가", 설비공학 논문집 17권 5호, 2005 // (Sang-Min Kim, Byung-Yoon Park, Jang-Yeul Sohn, "Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments.", Korean Journal Of Air-Conditioning and Refrigeration Engineering, Vol.17, No.5, 2005)
  3. 김선숙, 이정재, 이윤규, "외기조건에 따른 열회수형 환기시스템의 성능평가", 대한건축학회 논문집 24권 8호, 2008 // (Kim Sun-Sook, Yee Jurng-Jae, Lee Yun-Gyu, "Performance Evaluation of an Energy Recovery Ventilator with Various Outdoor Climate Conditions.", Journal of The Architectural Institute of Korea, Vol.24, No.8, 2008)
  4. 이명주, 김원석, 이우주, 이원택, "건축물에너지절약요소기술 적용에 따른 단독주택 에너지 요구량 절감률 변화에 관한 연구", 대한건축학회 논문집 28권 5호, 2012 // (Lee Myoung-Ju, Kim Won-Seok, Lee Woo-Joo, Lee Won-Taek, "A Study about Reduction Rates of Building Energy Demand for a Detached House according to Building Energy Efficient Methods.", Journal of The Architectural Institute of Korea, Vol.28, No.5, 2012)
  5. 이재동, "포스코 그린빌딩 개요", 건축환경설비 6권 2호, 2012
  6. 이진욱, 이승복, 김태연, "에너지 절감형 업무용 건물의 에너지 성능 측정 및 검증에 관한 사례 연구", 대한건축학회 논문집 31권 2호, 2015 // (Lee, Jin-Uk, Leigh, Seung-Bok, Kim, Taeyeon, "A Case Study on Energy Performance Measurement and Verification of an Energy Saving Office Building.", Journal of The Architectural Institute of Korea, Vol.31, No.2, 2015)
  7. 국토교통부, "건축물의 에너지절약설계기준 해설서", 국토교통부 고시 제 2015 - 1108호