초록

To study the effect of installation and the shapes of filling pieces used for windows on the infiltration rate, infiltration tests were performed with two types of sliding windows and two shapes for the filling pieces. Infiltration occurred most at the top and bottom parts of the center location where two windows overlap, indicating the necessity of a filling piece to be installed at these locations. Infiltration velocity is proportional to the square root of the pressure difference, complying well with the theoretical correlation. Infiltration is reduced about 50% by the filling piece installation. This study shows that filling pieces are essential and their shapes play significant roles in reducing the infiltration of windows.

키워드

참고문헌

  1. Jang, C. Y. and Lee, N. E., 2010, A Measurement and Evaluation of Air Tightness of temperable Low-e Windows, Proceedings of SAREK, pp. 368-371.
  2. Kim, S. S., Cho, S., Yoon, Y., J., and Park, H. S., 2005, The Study on the Determining of the Infiltration Coefficient by Window Types, Journal of Architectural Institute of Korea of Planning and Design, Vol. 21, No. 4, pp. 183-189.
  3. Chung, J. M., 2012, A study on the Development of the Door Hardwares Construction Specification for Safety and Quality Improvement of Building Door, MS thesis, Seoul National University of Science and Technology.
  4. Moon, S. D., Chung, J. M., and Ock, J. H., 2013, Analysis of the Causes of Defects in Fenestration Construction and Their Impacts on Construction Quality, Journal of the Korea Institute of Building Construction, Vol. 13, No. 4, pp. 341-350. https://doi.org/10.5345/JKIBC.2013.13.4.341
  5. Jeong, H. G., 2008, A Study on the Effect of Window System on Indoor Temperature and Building Energy Consumption, MS thesis, Seoul National University of Science and Technology.
  6. Park, J. J., Kim, Y. I., and Chung, K. S., 2013, Study of Infiltration due to Window Air Permeability in Officetel, Proceedings of SAREK, pp. 742-745.
  7. Korea Standard Association, 2013, KS F 2292, The test method of air tightness for windows and doors.