DOI QR코드

DOI QR Code

An Analysis on Building Shading Plan for a City Hall considering Energy Saving

  • Kim, Jin Lee (California State University of Long Beach) ;
  • No, Sang Tae (CSULB, Korea National University of Transportation)
  • Received : 2015.11.18
  • Accepted : 2016.04.01
  • Published : 2016.04.30

Abstract

Purpose: Recently, many public office buildings which were built by curtain wall increased rapidly, but the results of the investigation of the government, these buildings have been found that the heating and cooling thermal load is high, and showed low energy efficiency. Method: To evaluate the effects by applying outdoor louver and indoor blind, which can control solar radiation in order to reduce the heating and cooling load of public office building which was built by glass curtain wall. The heating and cooling load was calculated via Energyplus, building and outdoor louver, indoor blind were modeled by Google sketchup connected to Energyplus. Result: The results of this study were as follows; the case of applying various outdoor louver, the heating and cooling load all decreased as compared to the case without applying outdoor louver, the case of applying indoor blind, the heating and cooling load decreased as compared to the case without applying indoor blind, but indoor blind showed low energy performance comparing outdoor louver.

Keywords

References

  1. A news report on Excessive energy consuming public building of local government, Ministry of public administration and security of KOREA, 2010-2
  2. Kwon, Y. J., Lee, T. G., Cho, K. M., and Kim, J. H., A Study on Shading Design to Minimize Heating and Cooling Energy Demand. Korean Journal of the korea institute of ecological architecture and environment(KIAEBS), 2011-11, 67-72, 2011
  3. Kim, J. S., Lee, H., Oh, M. S., and Kim, H. S., A Study on Improvements of Envelope System for The Energy Saving in Curtain Wall Office Buildings. Korean Journal of KIAEBS, 6, 106-113, 2012
  4. Son, J. H., and Kim, S., A Study on Energy Reduction of Passive Factor Apply for the Improvement of Energy Performance in Public Building. Korean Journal of the Korean solar energy society, 31, 196-201, 2011
  5. Son, J. H., and Kin, S., A Study on Energy Saving Way of Domestic Public Buildings. Korean Magazine of the SAREK, 7, 625-630, 2011
  6. Kim, J. Y., Yook, I. S., Nam, H. J., Lee, J. S., Kim, J. M., and Cho, S, The Impact of Internal heat gain on Heating and Cooling Load in Curtain Wall Office Buildings. Korean Magazine of the SAREK, 6, 925-930, 2008