DOI QR코드

DOI QR Code

Measurement errors of the EIT systems using a phantom and conductive yarns

전기임피던스 단층촬영법을 이용한 외란위치 계측오차

  • Park, Ji Su (Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST)) ;
  • Koo, Sang-Mo (Dept. of Electronic Materials Engineering, Kwangwoon University) ;
  • Kim, Choong Hyun (Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST))
  • Received : 2016.01.29
  • Accepted : 2016.07.06
  • Published : 2016.08.01

Abstract

Electrical impedance tomography (EIT) has been applied to measure the location of external disturbance using a phantom and conductive yarns. According to the test results, the addition of carbon nanotube particles into the phantom does not show remarkable improvement in location errors. On the other hand combined fabric, conductive yarns with fabric, and non-woven fabric, were added to evaluate its performance as a fabric sensor. The combined fabric resulted in a decrease of 21.5% in the circumferential location error and a decrease of 50% in the radial location error, compared to those of the yarns. Additionally, it was revealed that the measurement error is almost linearly proportional to the conductivity of the phantom liquid and resistance of the conductive yarns. The combined fabric can be a promising material for fabric sensors in sports utilities and medical devices.

Keywords

References

  1. V. Sarode, P.M. Chimurkar, A.N. Cheeran, "Electrical Impedance Tomography based medical imaging using finite element method.", International Journal of Engineering Sciences & Emerging Technologies, Vol. 1, Ussue 2, pp. 83-39, February 2012. https://doi.org/10.7323/ijeset/v1_i2_10
  2. T.K. Bera and N. Jampana., "A Multifrequency Constant Current Source Suitable for Electrical Impedance Tomography", Proceedings of 2010 International Conference on Systems in Medicine and Biology. pp. 278-283, December 2010.
  3. T.K. Bera, S.K. Biswas, K. Rajan and J. Nagaraju, "Improving Image Quality in Electrical Impedance Tomography (EIT) Using Projection Error Propagation-Based Regularization (PEPR) Technique: A Simulation Study", J Electr Bioimp, Vol. 2, pp. 2-12, March 2011.
  4. T. J. Yorkey, J. G. Webster, and W. J. Tompkins, "Comparing reconstruction algorithms for electrical impedance tomography", IEEE Trans. Biomed. Eng., Vol. BME-34, No. 11, pp. 843-852, November 1987. https://doi.org/10.1109/TBME.1987.326032
  5. K.-N. Cho and H.-M. Jung, "Electrical and Physical Properties of Sheath-core Type Conductive Textile Sensor with Home-Textile", Fashion & Text. Res. J., Vol. 16, No. 1, pp. 145-152, January 2014. https://doi.org/10.5805/SFTI.2014.16.1.145
  6. T. K. Bera, J. Nagaraju, "Studying the resistivity imaging of chicken tissue phantoms with different current patterns in Electrical Impedance Tomography (EIT)", Measurement, Vol. 45, pp. 663-682, January 2012. https://doi.org/10.1016/j.measurement.2012.01.002
  7. EIDORS: Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software, http://eidors3d.sourceforge.net/, May 2015