DOI QR코드

DOI QR Code

Thermal performance prediction of amorphous steel fibers mixed into the floor heating system

비정질 강섬유 혼입 바닥난방시스템의 열성능 평가

  • Cho, Hyun (Research & Engineering Division, R&D CENTER, POSCO E&C) ;
  • Pang, Seung-Ki (Department of Architecture, Kyungmin College)
  • Received : 2016.03.02
  • Accepted : 2016.07.22
  • Published : 2016.09.30

Abstract

The thermal performance of amorphous steel fibers mixed floor heating system was evaluated. Analysis of results, depending on the hot water supply temperature changes, the average temperature of the bottom of the hot water supply temperature is an amorphous steel fiber floor heating system is about 2~4% higher. The average temperature of the floor surface to 1.5m air amorphous steel fiber system is 1~2% higher. The amount of heat supplied to indoor air (1.5m) from the bottom surface of amorphous steel fiber floor heating system is about 7~8% higher

본 연구에서는 비정질 강섬유 혼입 바닥몰탈을 이용한 바닥난방시스템과 일반 몰탈을 사용한 바닥난방시스템의 열성능을 비교 평가하기 위하여 시뮬레이션을 실시하였다. 시뮬레이션은 온수공급온도를 변화시켰으며 다음과 같은 결론을 얻었다. 바닥의 표면온도, 실내의 공기온도 등을 검토 결과 강섬유온돌을 사용할 경우에는 실내공기를 기준으로 하면 강섬유온돌이 일반온돌에 비해 7~9%에 가까운 열효율이 상승되었으며, 바닥의 온도를 기준으로 하면 2~4% 온도상승이 일어나는 것으로 나타났다.

Keywords

References

  1. Jung Hae-Kwon, Cho Dong-Woo, Yu Ki-Hyung, 2009, "Comparative Analysis on the Heat Transfer Characteristics between Dry and Wet Ondol Systems", Journal of the Architectural Institute of Korea, Vol. 25, No. 11, pp.315-322.
  2. Lee Tai-Gang, Lee Ju-Yeob, Song Min-Jeong, Kim Sun-Woo, 2013, "The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system", Journal of the Korea Institute of Ecological Architecture and Environment, Vol. 13, No. 3, pp.61-69.
  3. Ahn Byung-Wook, 1997, "Ondol Heated Room & its Indoor Thermal Environment", Journal of the Korean Society of Living Environment System, Vol. 4, No. 3, pp.1-12.
  4. Yoon Yong-Jin, Park Sang-Dong, Sohn Jang-Yeul, 1984, "Effect of an Asymmetric Radiation Field on Thermal Sensation with Radiant Heating" Journal of the Architectural Institute of Korea, Vol. 4, No. 2, pp.139-142.
  5. Chung Kwang-Seop, ,1998, "A Study on the Assessment of Local Thermal Sensation in Human Body by Varying Ondol Floor Surface Temperature" Jounal of the Korean Society of Living Environment System, Vol. 5, No. 2, pp.33-38.
  6. Lim Jae-Han, Song Jin-Hee, Koo Bo-Kyoung, Song Seung-Yeong, Seong Yoon-Bok, 2012, "Characteristic of Thermal Output of Thermally Activated Building System During the Heating Operation According to FDM Analysis", Society of Air-conditioning and refrigerating engineers of Korea, pp.218-223.
  7. Choi Jeong-Min, Lee Kyu-Nam, Ryu Seong-Ryoung, Kim Yong-Yee, Yeo Myoung-Souk, Kim Kwang-Woo, 2006, "A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel" Society of Air-conditioning and refrigerating engineers of Korea, pp.795-800.
  8. Choi Jeong-Min, Lee Kyu-Nam, Ryu Seong-Ryoung, Kim Yong-Yee, Yeo Myoung-Souk, Kim Kwang-Woo, 2007, "A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System" Society of Air-conditioning and refrigerating engineers of Korea, Vol. 19, No. 1, pp.77-85.
  9. Sohn Jang-Yeul, Chung Kwang-Seop, Ahn Byung-Wook, 1990, "An Experimental Results of the Transient Temperature Response of a Floor Heating Panel according to Varying Pipe Embedding Depth" Journal of the Architectural Institute of Korea, Vol. 6, No. 5, pp.185-191.
  10. Song Gook-Sup, 2005, "Effects of the Floor Surface Temperature and Metabolism on Scrotal Temperature" Journal of the Korean Society of Living Environment System, Vol. 12, No. 3, pp.185-191.
  11. Oh Byoung-Chil, Lee Kun-Young, 1985, "A Study on the Heat Efficiency in Ondol Heating System by different Heat-Accumulation Material" Journal of the Architectural Institute of Korea, Vol. 5, No. 2, pp.295-298.