Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island

제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태

  • 김봉애 (제주대학교 생활환경복지학부) ;
  • 고연숙 (제주대학교 생활환경복지학부)
  • Received : 2017.08.04
  • Accepted : 2017.10.22
  • Published : 2017.12.26

Abstract

This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.

Keywords

Acknowledgement

Supported by : 제주대학교

References

  1. American Public Health Association & American Academy of Pediatrics. (2011). Caring for Our Children: National Health and Safety Performance Standards; Guidelines for Early Care and Education Programs, Third Edition, 212-213. http://cfoc.nrckids.org/WebFiles/CFOC3_updated_final.pdf
  2. Aoki, T., Suto, C., Mizutani, A., & Ohsawa, T. (2009). Thermal Performance and Environment Evaluated from the Fluctuation of Indoor Temperature and Humidity in Winter, Journal of Environmental Engineering(Transactions of AIJ), 74(637), 305-314. https://doi.org/10.3130/aije.74.305
  3. ASHRAE. (2005). 2005 ASHRAE Handbook Fundamentals, CHAPTER 8 Thermal Comfort, 8.15.
  4. Byun, H., & Choi, M. (2006). A Study on the Composition and Planning Guidelines of Outdoor Play Environment at Child Care Centers in Seoul, Korean Journal of Human Ecology, 15(2), 209-225.
  5. Byun, H., Choi, M., & So, K. (2013). A Study on Characteristics of Building, Outdoor Playground & Equipment in Child Care Center, Journal of the Korean Housing Association, 24(6), 9-18. https://doi.org/10.6107/JKHA.2013.24.6.009
  6. Choi, Y. (2010). A Study on the Composition of the Interior Space of the Child Care Facilities for Employees in Public Office. Korea Institute of Youth Facility & Environment, 8(3), 89-99.
  7. Choi, K. (1997). A Study on the Behavior Survey for Space Organization of Toddlers' Activity Room at Day Care Center, Journal of the Architectural Institute of Korea, 13(11), 137-148.
  8. Chol, K., Bea, S., Kang, M., & Ju, S. (2000). A Study on the Architectural Design Guidelines for Child Care Centers. Journal of the Architectural Institute of Korea, 16(12), 1-10.
  9. Chung, J. (2001). A Study on the Architectural Planning of Nurseries-Focus on spatial organization planning-, Journal of the Architectural Institute of Korea, 7(11), 57-64.
  10. Fujii, R., & Sadayuki, M. (2016). A Research on Creating a Good Environment of One-Year-Old Children's Room in Japaness Child Daycare Centers, Journal of Architecture Planning, 81(729), 2383-2391. https://doi.org/10.3130/aija.81.2383
  11. Harper, G.Y. (1961). Airborne Micro-Organisms: Survival Tests with Four Viruses, J. Hyg., Camb., 59, 479-486. https://doi.org/10.1017/S0022172400039176
  12. Hori, Y., Ito, N., Sunaga, N., & Muro, K. (1997). Evaluation of Thermal Comfort in a Non-Uniform Thermal Environment-Effect of Floor Temperature on Thermal Comfort and Prediction of Thermal Comfort on the Basis o f Local Thermal Sensation, Journal Architecture Planning Environmental Engineering, Architectural Institute of Japan, 501, 37-44.
  13. Jang, S. (2006). A Cross-Cultural Study on the Seating Style of Children between Korea and U.S.A Viewed from Activity Analysis in Child Care Centers, Family and Environment Research, 44(4), 159-173.
  14. Jang, S., & Shin, K. (2010). Observation Research on Preschoolers' Play Behavior for the Design Plan for the Indoor Play Area of Day Care Centers-Focusing on Preschoolers of Day Care Centers between Korea and US-, Journal of the Korean Institute of Interior Design, 19(6), 214-223.
  15. Ju, S. (2004). A Study on the Planning of Infant Nursing Rooms of Child Care Centers in U.S.A., Journal of the Architectural Institute of Korea, 20(11), 123-130.
  16. Ju, S. (2005). A Study on the Planning of Nursing Rooms of Child Care Centers in U.S.A., Journal of the Korean Housing Association, 16(6), 129-137.
  17. Kim, Y. (2009). Spacial Organization of Day Care Centers in Australia-Focusing on the Center-based Long-Day Care Centers Sponsored by Universities in Sydney -, Journal of the Architectural Institute of Korea, 25(10), 67-74.
  18. Kim, Y., Choi, M., & Park, J. (2011). A Preliminary Study of Licensing Facilitation Standards for Improvements in Quality for Childcare Centers. Korea Association of Human Ecology, 20(3), 691-711. https://doi.org/10.5934/KJHE.2011.20.3.691
  19. Kim, Y., & Choi, K. (2007). Case Studies on the Design Criteria of Outstanding Child Care Centers in Korea. Journal of the Architectural Institute of Korea, 23(8), 99-106.
  20. Kim, Y., & Lim, S. (2007). Measurement of Indoor Air Quality in a Kindergarten, Review of the Korean Institute of Educational Facilities, 14(1), 52-57.
  21. Kim, Y., Yun, G., & Lim, B. (2012). Measurement of Indoor Air Quality in a Kindergarten of the City, Journal of the Regional Association of Architectural Institute of Korea, 14(4), 315-320.
  22. Kurabuchi, T., Ogasawara, T., Kumagai, K., & Asari, Y. (2009). Relationship between Absolute Humidity and Virus Survival Rate Affecting Influenze Transmission, The Society for Heating, Air-Conditioning Sanitary Engineers for Japan, 1339-1342.
  23. Lee, D., Yang, J., Oh, H., Nam, I., Kim, J., Park, E., & Sohn, J. (2014). Study on the Thermal Comfort of Children for Improvement of Indoor Environment at Childcare Center In Seoul, Korea, Journal of Korea Facility Management Association, 9(2), 37-39.
  24. Lee, J., Kim, D., Choi, S., & Byun, N. (2016). Kindergarten Facility and Environment Design Based on the Child Development Theory-Focused on Foreign Cases, Journal of the Architectural Institute of Korea Planning & Design, 32(4), 49-58. https://doi.org/10.5659/JAIK_PD.2016.32.4.49
  25. Lee, K. (2005). A Study on the Space Program of the Day-Care Centers in Workshop Area, Korean Institute of Interior Design Journal, 14(1), 109-117.
  26. Lim, J., & Sohn, J. (2010). Methods for Management and Improvement of Indoor Air Quality in Child Care Centers, Journal of the Architectural Institute of Korea, 26(9), 227-236.
  27. Lowen, A.C., Mubareka, S., Steel, J., & Palese, P. (2007). Influenze Virus Transmission Is Dependent on Relative Humidity and Temperature, PLos Parhog, 3, 1470-1476.
  28. Ministry of education. (2016). Enforcement decree for the school health act, http://www.law.go.kr/lsInfoP.do?lsiSeq=186013&efYd=2017 0301#0000
  29. Ministry of education, culture, sports, science and technology-japan(MEXT). (2009). School environment management manuel-Chapter 2 School environment and health standard 1-, 15-16, http://www.mext.go.jp/component/a_menu/education/detail/_ _icsFiles/afieldfile/2010/04/08/1292465_02.pdf
  30. Ministry of health. (2012). Infectious Disease Control Guidelines in the Nursery, 17-19. http://www.mhlw.go.jp/bunya/kodomo/pdf/hoiku02_1.pdf
  31. Morimoto, N., Aoki, T., Mizutani, A., & Ohsawa, T. (2009). A study on the investigation and the improvement of indoor environment in kindergarten-Measurement survey on the health problems of the childhood in winter-, Proceedings of Tokai Chapter Architectural Research Meeting, 389-392.
  32. National Association for the Education of Young Children. (2017). NAEYC Program Standards and Accreditation Assessment Items Standard 9: Physical Environment, 1-10.
  33. Park, J., Chol, M., & Kim, Y. (2011). A Study on the Characteristics of Area and Spatial Elements Based on the Building Size of Childcare Center, Journal of the Korean Housing Association, 22(1), 65-73. https://doi.org/10.6107/JKHA.2011.22.1.065
  34. Park, S., Kim, J., Joe, G., Yeo, M., & Kim, K. (2015). Analysis of Size-resolved Indoor and Outdoor Particle Sources to Indoor Particles in a Child-care Center, Journal of the Architectural Institute of Korea Planning & Design, 31(12), 215-222. https://doi.org/10.5659/JAIK_PD.2015.31.12.215
  35. Seok, J. (2013). A Study on the Planning of the Daycare Center for Children Under Three in France-Survey of the Daycare for Children Under Three in Paris-. Journal of the Architectural Institute of Korea Planning & Design, 29(8), 139-148. https://doi.org/10.5659/JAIK_PD.2013.29.8.139
  36. Shoji, M. (1994). Special issue : Common cold and influenza. Commong cold and seasons. Focusing on influenza epidemics, The Japanese Journal of Clinical and Experimental Medicine, 17(2), 3030-3038.
  37. Yoo, B. (2014). A Study on Characteristics of Space Planning Based on the Types of Childcare Center in Ulsan. Journal of the Architectural Institute of Korea Planning and Design, 30(11), 39-47. https://doi.org/10.5659/JAIK_PD.2014.30.11.39
  38. The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan(SHASE). (1997). 快適な温熱環境 のメカニズム-豊かな生活空間をめざして, The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan.
  39. U.S. General Services Adiministration(GSA). (2003). Child Care Center Design Guide, 113-114. https://www.gsa.gov/graphics/pbs/designguidesmall.pdf#sear ch=%27child+care+center+design+guide%27