DOI QR코드

DOI QR Code

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min (Department of Electrical and Computer Engineering, Sungkyunkwan University) ;
  • Oh, Chang-Yeol (Department of Electrical and Computer Engineering, Sungkyunkwan University) ;
  • Sung, Won-Yong (Department of Electrical and Computer Engineering, Sungkyunkwan University) ;
  • Ahn, Jung-Hoon (Department of Electrical and Computer Engineering, Sungkyunkwan University) ;
  • Lee, Byoung Kuk (Department of Electrical and Computer Engineering, Sungkyunkwan University)
  • Received : 2016.04.01
  • Accepted : 2016.08.06
  • Published : 2017.01.02

Abstract

The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

Keywords

References

  1. H. M. Ahn, C. Y. Oh, W. Y. Sung, J. H. Ahn, and B. K. Lee, "Analysis and design of LCL filter with passive damping circuits for three-phase grid-connected inverters," ICPE 2015-ECCE Asia, Seoul, South Korea, pp. 652-658, 1-5 June 2015.
  2. P. Channegowda and V. John, "Filter Optimization for Grid Interactive Voltage Source Inverters," IEEE Trans. Ind. Electron., vol. 57, no. 12, pp. 4106-4114, Dec. 2010. https://doi.org/10.1109/TIE.2010.2042421
  3. W. Wu, Y. He and T. Tang, "A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter," IEEE Trans. Ind. Electron., vol. 60, no. 10, pp. 4339-4350, Oct. 2013. https://doi.org/10.1109/TIE.2012.2217725
  4. M. Cespedes, T. Beechner, L. Xing and J. Sun, "Stabilization of Constant-Power Loads by Passive Impedance Damping," APEC 2010, Palm Springs, CA, 21-25, Feb. 2010.
  5. T. C. Wang, Z. Ye, G. Sinha, and X. Yuan, "Output Filter Design for a Grid-interconnected Three-Phase Inverter," PESC 2003, Acapulco (Mexico), Jun. 2003.
  6. Q. Liu, L. Peng, Y. Kang, S. Tang, Deliang Wu, and Y. Qui, "A Novel Design and Optimization Method of an LCL Filter for a Shunt Active Power Filter," IEEE Trans. Ind. Electron., vol. 61, no. 8, pp. 4000-4010, Aug. 2014. https://doi.org/10.1109/TIE.2013.2282592
  7. X. Guo, X. You, X. Li, R. Hao, and D. Wang, "Design Method for the LCL Filters of Three-phase Voltage Source PWM Rectifiers," J. Power Electron., vol. 12, no. 4, pp. 559-566, Jul. 2012 https://doi.org/10.6113/JPE.2012.12.4.559
  8. M. Liserre, F. Blaabjerg, and S. Hansen, "Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier," IEEE Trans. Ind. App., vol. 41, no. 5, pp. 1281-1291, Sept. 2015
  9. R. Pena-Alzola, M. Liserre, F. Blaabjerg, R. Sebastian, J. Dannehl, and F. Wilhelm Fuchs, "Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters," IEEE Tran. Power Electron., vol. 28, no. 6, pp. 2642-2646, Jun. 2013, https://doi.org/10.1109/TPEL.2012.2222931
  10. F. Golnaraghi, B. C. Kuo, "Frequency-Domain Analysis," in Automatic Control Systems, 9th ed. New York: Wiley, 2009, pp.418-426
  11. IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE standard 519-1992, May 10, 1992
  12. B. Ren, X. Sun, S. An, X. Cao, and Q. Zhang "Analysis and Design of an LCL Filter for the Threelevel Grid Connected Inverter," 2012 IEEE 7th Int. Power Electron. and Motion Control Conf., China, Harbin, pp. 2023-2027, Jun. 2012.