DOI QR코드

DOI QR Code

관상동맥 내의 나선형 유동이 협착도에 따라 분획 혈류 예비능에 미치는 영향에 관한 수치해석

THE INFLUENCES OF SWIRL FLOW ON FRACTIONAL FLOW RESERVE IN MILD/MODERATE/SEVERE STENOTIC CORONARY ARTERIAL MODELS

  • 이경은 (강원대학교 기계의용공학과) ;
  • 김국태 (강원대학교 기계의용공학과) ;
  • 류아진 (강원대학교 기계의용공학과) ;
  • 심은보 (강원대학교 기계의용공학과)
  • Lee, Kyung Eun (Department of Mechanical and Biomedical Engineering, Kangwon National University) ;
  • Kim, Gook Tae (Department of Mechanical and Biomedical Engineering, Kangwon National University) ;
  • Ryu, Ah-Jin (Department of Mechanical and Biomedical Engineering, Kangwon National University) ;
  • Shim, Eun Bo (Department of Mechanical and Biomedical Engineering, Kangwon National University)
  • 투고 : 2017.01.05
  • 심사 : 2017.03.15
  • 발행 : 2017.03.31

초록

Swirl flow is often found in proximal coronary arteries, because the aortic valves can induce swirl flows in the coronary artery due to vortex formation. In addition, the curvature and tortuosity of arterial configurations can also produce swirl flows. The present study was performed to investigate fractional flow reserve alterations in a post-stenotic distal part due to the presence of pre-stenotic swirl flow by computational fluid dynamics analysis for virtual stenotic models by quantifying fractional flow reserve(FFR). Simplified stenotic coronary models were divided into those with and without pre-stenotic swirl flow. Various degrees of virtual stenosis were grouped into three grades: mild, moderate, and severe, with degree of stenosis of 0 ~ 40%, 50 ~ 60%, and 70 ~ 90%, respectively. In this study, three-dimensional computational hemodynamic simulations were performed under hyperemic conditions in virtual stenotic coronary models by coupling with a zero-dimensional lumped parameter model. The results showed that the influence of pre-stenotic swirl inflow is dominant on FFR alteration in mild stenosis, whereas stenosis is dominant on FFR alteration in moderate/severe stenosis. The decrease in FFR caused by swirl flow is more significant in mild stenosis than moderate/severe stenosis. Biomechanical modeling is useful for clinicians to provide insight for medical intervention strategies. This hemodynamic-based parameter study could play a critical role in the development of a non-invasive imaging-based strategy-support system for percutaneous transluminal angioplasty in cases of mild/moderate stenosis.

키워드

참고문헌

  1. 1996, Frazin, L.J., Vonesh, M.J., Chandran, K.B., Shipkowitz, T., Yaacoub, A.S. and McPherson, D.D., "Confirmation and Initial Documentation of Thoracic and Abdominal Aortic Helical Flow: An Ultrasound Study," Journal of the American Society for Artificial Internal Organs, Vol.42, No.6, pp.951-956. https://doi.org/10.1097/00002480-199642060-00006
  2. 2007, Frydrychowicz, A., Winterer, J.T., Zaitsev, M., Jung, B., Henning, J., Langer, M. and Markl, M., "Visualization of iliac and proximal femoral artery hemodynamics using time-resolved 3-D phase contrast MRI at 3T," Journal of Magnetic Resonance Imaging, Vol.25, No.5, pp.1085-1092. https://doi.org/10.1002/jmri.20900
  3. 2001, Kaazempur-Mofrad, M.R. and Ethier, C.R., "Mass transport in an anatomically realistic human right coronary artery," Annals of Biomedical Engineering, Vol.29, No.2, pp.121-127. https://doi.org/10.1114/1.1349704
  4. 1993, Kilner, P.J., Yang, G.Z., Mohiaddin, R.H., Firmin, D.N. and Longmore, D.B., "Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping," Circulation, Vol.88, No.5, pp.2235-2247. https://doi.org/10.1161/01.CIR.88.5.2235
  5. 2014, Ha, H. and Lee, S.J., "Effect of swirling inlet condition on the flow field in a stenosed arterial vessel model," Medical Engineering & Physics, Vol.36, No.1, pp.119-128. https://doi.org/10.1016/j.medengphy.2013.10.008
  6. 2003, Houston, J.G., Gandy, S.T., Sheppard, D.G., Dick, J.B., Belch, J.J. and Stonebridge, P.A., "Two-dimensional flow quantitative MRI of aortic arch blood flow patterns: Effect of age, sex, and presence of carotid atheromatous disease on prevalence of spiral blood flow," Journal of Magnetic Resonance Imaging, Vol.18, No.2, pp.169-174. https://doi.org/10.1002/jmri.10341
  7. 2009, Liu, X., Pu, F., Fan, Y., Deng, X., Li, D. and Li, S., "A numerical study on the flow of blood and the transport of LDL in the human aorta: the physiological significance of the helical flow in the aortic arch," American Journal of Physiology-Heart and Circulatory Physiology, Vol.297, No.1, pp.H163-H170. https://doi.org/10.1152/ajpheart.00266.2009
  8. 2008, Verhey, J.F. and Bara, C., "Influence on fluid dynamics of coronary artery outlet angle variation in artificial aortic root prosthesis," Biomed Engineering Online, Vol.7, No.9, pp.1-9. https://doi.org/10.1186/1475-925X-7-1
  9. 2011, Morbiducci, U., Ponzini, R., Rizzo, G., Cadioli, M., Esposito, A., Montevecchi, F.M. and Redaelli, A., "Mechanistic insight into the physiological relevance of helical blood flow in the human aorta: an in vivo study," Biomechanics and Modeling in Mechanobiology, Vol.10, No.3, pp.339-355. https://doi.org/10.1007/s10237-010-0238-2
  10. 2011, Lee, K.E., Lee, J.S. and Yoo, J.Y., "A numerical study on steady flow in helically sinuous vascular prostheses," Medical Engineering & Physics, Vol.33, No.1, pp.38-46. https://doi.org/10.1016/j.medengphy.2010.09.005
  11. 2015, Liu, X., Sun, A., Fan, Y. and Deng, X., "Physiological significance of helical flow in the arterial system and its potential clinical applications," Annals of Biomedical Engineering, Vol.43, No.1, pp.3-15. https://doi.org/10.1007/s10439-014-1097-2
  12. 2009, Paul, M.C. and Larman, A., "Investigation of spiral blood flow in a model of arterial stenosis," Medical Engineering & Physics, Vol.31, No.9, pp.1195-1203. https://doi.org/10.1016/j.medengphy.2009.07.008
  13. 1996, Caro, C.G., Doorly, D.J., Tarnawski, M., Scott, K.T., Long, Q. and Dumoulin, C.L., "Non-planar curvature and branching of arteries and non-planar-type flow," Proceedings of the Royal Society of London A: Mathematical, Physical and Engineering Sciences. The Royal Society, Vol.452, No.1944, pp.185-197. https://doi.org/10.1098/rspa.1996.0011
  14. 2013, Caro, C.G., Seneviratne, A., Heraty, K.B., Monaco, C., Burke, M.G., Krams, R., Chang, C.C., Coppola, G. and Gilson, P., "Intimal hyperplasia following implantation of helical-centreline and straight-centreline stents in common carotid arteries in healthy pigs: influence of intraluminal flow," Journal of the Royal Society Interface, Vol.10, No.89, p.20130578. https://doi.org/10.1098/rsif.2013.0578
  15. 2009, Cookson, A.N., Doorly, D.J. and Sherwin, S.J., "Mixing through stirring of steady flow in small amplitude helical tubes," Annals of Biomedical Engineering, Vol.37, No.4, pp.710-721. https://doi.org/10.1007/s10439-009-9636-y
  16. 2009, Sung, K.H., Ro, K.C. and Ryou, H.S., "Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery," Korea-Australia Rheology Journal, Vol.21, No.2, pp.119-126.
  17. 2013, Keshavarz-Motamed, Z., Garcia, J. and Kadem, L., "Fluid dynamics of coarctation of the aorta and effect of bicuspid aortic valve," PLoS One, Vol.8, No.8, p.e72394. https://doi.org/10.1371/journal.pone.0072394
  18. 2004, Stonebridge, P.A., Buckley, C., Thompson, A. and Dick, J., "Non spiral and spiral (helical) flow patterns in stenoses: in vitro observations using spin and gradient echo magnetic resonance imaging (MRI) and computational fluid dynamic modeling," International Angiology, Vol.23, No.3, p.276.
  19. 2014, Kwon, S.S., Chung, E.C., Park, J.S., Kim, G.T., Kim, J.W., Kim, K.H., Shin, E.S. and Shim, E.B., "A novel patient-specific model to compute coronary fractional flow reserve," Progress in Biophysics and Molecular Biology, Vol.116, No.1 pp.48-55. https://doi.org/10.1016/j.pbiomolbio.2014.09.003
  20. 2015, Iori, F., Grechy, L., Corbett, R.W., Gedroyc, W., Duncan, N., Caro, C.G. and Vincent, P.E., "The effect of in-plane arterial curvature on blood flow and oxygen transport in arterio-venous fistulae," Physics of Fluids, Vol.27, No.3, p.031903. https://doi.org/10.1063/1.4913754
  21. 2008, Achenbach, S., "Quantification of Coronary Artery Stenoses by Computed Tomography," JACC: Cardiovascular Imaging, Vol.1, pp.472-474. https://doi.org/10.1016/j.jcmg.2008.05.008
  22. 2013, Cury, R.C., Feuchtner, G.M., Batlle, J.C., Peña, C.S., Janowitz, W., Katzen, B.T. and Ziffer, J.A., "Triage of patients presenting with chest pain to the emergency department: implementation of coronary CT angiography in a large urban health care system," American Journal of Roentgenology, Vol.200, No.1, pp.57-65. https://doi.org/10.2214/AJR.12.8808
  23. 1973, Young, D.F. and Tsai, F.Y., "Flow characteristics in models of arterial stenosis I. steady flow," Journal of biomechanics, Vol.6, No.4, pp.395-410. https://doi.org/10.1016/0021-9290(73)90099-7
  24. 2012, Klabunde, R., "Cardiovascular Physiology concepts," The 2nd Edition, Lippincott Williams & Wilkins.
  25. 2016, Lee, K.E., Kim, G.T., Lee, J.S., Chung, J.H., Shin, E.S. and Shim, E.B., "A patient-specific virtual stenotic model of the coronary artery to analyze the relationship between fractional flow reserve and wall shear stress," International Journal of Cardiology, Vol.222, pp.799-805. https://doi.org/10.1016/j.ijcard.2016.07.153
  26. 1992, Kelly, R. and Fitchett, D., "Noninvasive determination of aortic input impedance and external left ventricular power output: a validation and repeatability study of a new technique," Journal of the American College of Cardiology, Vol.20, No.4, pp.952-963. https://doi.org/10.1016/0735-1097(92)90198-V
  27. 2006, Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I. and Struijker-Boudier, H., "Expert consensus document on arterial stiffness: methodological issues and clinical applications," Eur Heart J, Vol.27, No.21, pp.2588-2605. https://doi.org/10.1093/eurheartj/ehl254
  28. 2005, Verbeke, F., Segers, P., Heireman, S., Vanholder, R., Verdonck, P. and Van Bortel, L.M., "Noninvasive assessment of local pulse pressure: importance of brachial-to-radial pressure amplification," Hypertension, Vol.46, No.1, pp.244-248. https://doi.org/10.1161/01.HYP.0000166723.07809.7e
  29. 2012, Sankaran, S., Moghadam, M.E., Kahn, A.M., Tseng, E.E., Guccione, J.M. and Marsden, A.L., "Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery," Annals of Biomedical Engineering, Vol.40, No.10, pp.2228-2242. https://doi.org/10.1007/s10439-012-0579-3
  30. 1990, Schreiner, W., Neumann, F. and Mohl, W., "The role of intramyocardial pressure during coronary sinus interventions: a computer model study," IEEE Transactions on Biomedical Engineering, Vol.37, No.10, pp.956-967. https://doi.org/10.1109/10.102808
  31. 1998, Du Toit, C.G., "Finite element solution of the Navier-Stokes equations for incompressible flow using a segregated algorithm," Computer Methods in Applied Mechanics and Engineering, Vol.151, No.1-2, pp.131-141. https://doi.org/10.1016/S0045-7825(97)00107-2
  32. 1993, Haroutunian, V. Engelman, M.S. and Hasbani, I., "Segregated finite element algorithms for the numerical solution of large-scale incompressible flow problems," International Journal for Numerical Methods in Fluids, Vol.17, No.4, pp.323-348. https://doi.org/10.1002/fld.1650170405
  33. 1994, Shim, E.B. and Chang, K.S., "Three-dimensional vortex flow past a tilting disc valve using a segregated finite element scheme," Computational Fluid Dynamics Journal, Vol.3, pp.205-222.
  34. 1997, Shim, E.B. and Chang, K.S., "Numerical analysis of three-dimensional Bjork Shiley valvular flow in an aorta," Journal of Biomechanical Engineering, Vol.119, No.1, pp.45-51. https://doi.org/10.1115/1.2796063
  35. 1998, White, F.M., "Fluid mechanics. 4Th Ed," McGraw-Hill Higher Education.
  36. 1974, Gould, K.L., Lipscomb, K. and Hamilton, G.W., "Physiologic basis for assessing critical coronary stenosis: instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve," The American Journal of Cardiology, Vol.33, No.1, pp.87-94. https://doi.org/10.1016/0002-9149(74)90743-7
  37. 2010, Bark, D.L. and Ku, D.N., "Wall shear over high degree stenoses pertinent to atherothrombosis," Journal of Biomechanics, Vol.43, No.15, pp.2970-2977. https://doi.org/10.1016/j.jbiomech.2010.07.011
  38. 1998, Baumgart, D., Haude, M., Goerge, G., Ge, J., Vetter, S., Dagres, N., Heusch, G. and Erbel, R., "Improved assessment of coronary stenosis severity using the relative flow velocity reserve," Circulation, Vol.98, No.1, pp.40-60. https://doi.org/10.1161/01.CIR.98.1.40
  39. 2014, Gaur, S., Bezerra, H.G., Lassen, J.F., Christiansen, E.H., Tanaka, K., Jensen, J.M., Oldroyd, K.G., Leipsic, J., Achenbach, S. and Kaltoft, A.K., "Fractional flow reserve derived from coronary CT angiography: Variation of repeated analyses," Cardiovascular Computed Tomography, Vol.8, No.4, pp.307-314. https://doi.org/10.1016/j.jcct.2014.07.002
  40. 2011, Koo, B.K., Erglis, A., Doh, J.H., Daniels, D.V., Jegere, S., Kim, H.S., Dunning, A., DeFrance, T., Lansky, A. and Leipsic, J., "Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms: results from the prospective multicenter DISCOVER-FLOW(Diagnosis of Ischemia-Causing Stenoses Obtained Via Noninvasive Fractional Flow Reserve) study," The American College of Cardiology, Vol.58, No.19, pp.1989-1997. https://doi.org/10.1016/j.jacc.2011.06.066
  41. 2013, Nakazato, R., Park, H.B., Berman, D.S., Gransar, H., Koo, B.K., Erglis, A., Lin, F.Y., Dunning, A.M., Budoff, M.J. and Malpeso J., "Noninvasive fractional flow reserve derived from computed tomography angiography for coronary lesions of Intermediate Stenosis Severity Results from the DeFACTO Study," Circulation: Cardiovascular Imaging, Vol.6, No.6, pp.881-889. https://doi.org/10.1161/CIRCIMAGING.113.000297
  42. 2014, Norgaard, B.L., Leipsic, J., Gaur, S., Seneviratne, S., Ko, B.S., Ito, H., Jensen, J.M., Mauri, L., De Bruyne, B. and Bezerra, H., "Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps)," The American College of Cardiology, Vol.63, No.12, pp.1145-1155. https://doi.org/10.1016/j.jacc.2013.11.043
  43. 2014, Renker, M., Schoepf, U.S., Wang, R., Meinel, F.G., Rier, J.D., Bayer, R.R., Möllmann, H., Hamm, C.W., Steinberg, D.H. and Baumann, S., "Comparison of Diagnostic Value of a Novel Noninvasive Coronary Computed Tomography Angiography Method Versus Standard Coronary Angiography for Assessing Fractional Flow Reserve," The American Journal of Cardiology, Vol.114, No.9, pp.1303-1308. https://doi.org/10.1016/j.amjcard.2014.07.064
  44. 2002, Shalman, E., Rosenfeld, M., Dgany, E. and Einav, S., "Numerical modeling of the flow in stenosed coronary artery. The relationship between main hemodynamic parameter," Computers in Biology and Medicine, Vol.32, No.5, pp.329-344. https://doi.org/10.1016/S0010-4825(01)00033-6
  45. 2013, Taylor, C.A., Fonte, T.A. and Min, J.K., "Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis," Journal of the American College of Cardiology, Vol.61, No.22, pp.2233-2241. https://doi.org/10.1016/j.jacc.2012.11.083
  46. 1995, Tron, C., Donohue, T.J., Bach, R.G., Aguirre, F.V., Caracciolo, E.A., Wolford, T.L., Miller, D.D. and Kern, M.J., "Comparison of pressure-derived fractional flow reserve with poststenotic coronary flow velocity reserve for prediction of stress myocardial perfusion imaging," Journal of American Heart, Vol.130, No.4. pp.723-733. https://doi.org/10.1016/0002-8703(95)90070-5