Effect of Forceps Jars with Holes on the Drying Time, Rate of Wet Pack, Cost of Rewashing Linen and Maintenance of Sterilization

타공작업이 이동겸자의 건조시간, Wet Pack율, 린넨 세탁비용 및 오염여부에 미치는 영향

  • Received : 2017.09.29
  • Accepted : 2017.12.21
  • Published : 2017.12.30

Abstract

Objectives : This study aims to design a method for drying forceps jars. As part of the process, holes were made in the forceps jars. Drying time, rate of wet pack, and cost of rewashing linen were then determined. Moreover, the study looked into the bacteria incidence rate in the forceps jars. This study suggests a practical way for preventing infection in a hospital through a surgical device. Methods : This study investigated the effect of forceps jars with holes on reducing drying time, rate of wet pack, and cost of rewashing linen. It also looked into the bacteria incidence rate in the forceps jars through a parallel design. Data was collected and analyzed using SPSS version 21. Results : The drying time of a forceps jars was remarkably reduced from $18.44{\pm}0.2$ minutes(non-hole forceps jars) to $0.58{\pm}0.02$ minutes(4-hole forceps jars). The rate of wet pack of non-hole forceps jars was 51.4%. However, the rate of 4-hole forceps jars reached 4.6%. The cost of rewashing linen saw a decline from 38,073 won to 3,381 won. In addition, no bacteria and virus were detected from the 24-hours usage of forceps jars even though the jars had holes. Conclusions : The 4-hole forceps jars greatly increased work efficiency as a result of the reduced drying time, rate of wet-pack and cost of rewashing linen. The 4-hole forceps jars did not influence their sterilizing effect.

Keywords

References

  1. O.K. Park, Y,K. Kim, J.S. Kim, J.M. Kim, I.H. Kim, J.E. Park, et al.(2015), Nursing and Microbiology, Soomoonsa Pub, pp.51-71.
  2. W.A. Rutala, D.J. Weber(2013), Disinfection and Sterilization: An overview, American Journal of Infection Control, Vol.41(5);S2-S5. https://doi.org/10.1016/j.ajic.2012.11.005
  3. Korean Association of Infection Control Nurses(2012), Infection Management, Hyunmoonsa Pub, pp.135-145.
  4. C. Wang, Y. Chen, F. Yang, J. Ren, Xin, Yu, J. Wang, et al.(2016), Efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system, American Journal of Infection Control, Vol.44(8);e141-e143. https://doi.org/10.1016/j.ajic.2016.03.065
  5. http://www.lso-inc.com/sterilization-validationservices/iso17665-steam-sterilization.html
  6. S.P. Eder(2014), A multidisciplinary approach to instrument availability, AORN Journal, Vol.99(4);C7-C8. https://doi.org/10.1016/S0001-2092(14)00289-0
  7. S.H. Kim(2014), Medical Microbiology and Nursing, Hyunmoonsa Pub, pp.56-72.
  8. http://www.law.go.kr/admRulLsInfoP.do?admR ulSeq=2000000014476
  9. R. Seavey(2016), Troubleshooting failed sterilization loads: Process failures and wet packs/loads, American Journal of Infection Control, Vol.44(5);29-34.
  10. Y.H. Kim(2017), Infection Microorganisms and Nursing, Hyunmoonsa Pub, pp.319-345.
  11. AORN(2013), RP Summary: Recommended Practices for Sterilization, AORN Journal, Vol.97(5);534-537. https://doi.org/10.1016/j.aorn.2013.02.006
  12. A.F. Widmer, R. Frei, C. Wendt(2015), Decontamination, Disinfection, and Sterilization, Manual of Clinical Microbiology, Washington D.C: ASM Press, pp.183-216.
  13. Centers for Disease Control(2008), Guidelines for Disinfection and Sterilization in Healthcare Facilities, http://www.cdc.gov/ncidod/dhqp/sterile.htm
  14. J. Hart(2012), Reusable Sterilization Wrap, Canadian Green Health Care Digest November 2, pp.1-6.
  15. R. Seavey(2013), High-level disinfection, sterilization, and antisepsis: Current issues in reprocessing medical and surgical instruments, American Journal of Infection Control, Vol.41(5);S111-S117.
  16. J.Y. Ahn, N.S. Yoon(2004), Effect on Contamination Status of the Sterile Packs, Journal of Soonchunhyang Medical College, Vol.10(3);2101-2104.
  17. H.Y. Kim, E.J. Lee, E.K. Jang, Y.A. Park(2010), A Study for Infection Control Standards for Medical Devices in NICU, Journal of Korean Clinical Nursing Research, Vol.16(2);69-84.
  18. J.H. Kim, G.W. Kim(2013), Recognition of Medical Consumer over the Infection Control of Dental Clinic, Korea Contents Association, Vol.13(11);306-311. https://doi.org/10.5392/JKCA.2013.13.11.306
  19. H.Y. Jung, Y.K. Jung(2013), Recognition and Performance Level of Hospital Infection Control in Nurses of Long-term Care Hospital, The Korean Journal of Health Service Management, Vol.7(4);131-141. https://doi.org/10.12811/kshsm.2013.7.4.131
  20. S.Y. Jeong, H.S. OH, H.K. Chun(2015), Analysis of the Status of Infection Controls after Application of the Healthcare Accreditation System, The Korean Journal of Health Service Management, Vol.9(4);33-49. https://doi.org/10.12811/kshsm.2015.9.4.033