Abstract

This study is a secondary study that is a cyclic seismic test of High depth hybrid composite beam and column connection after the primary bending strength test of a high depth Hybrid composite beam. Total of 3 seismic test specimens were prepared to cyclic test. The bracket and beam web spliced by high strength bolt and the bracket and beam upper flange was spliced by welding. Test results showed that the seismic strength was higher than the plastic moment($M_p$) in the positive negative moment section, the requirement of composite intermediate moment frame wes satisfied. Therefore, the requirement of intermediate moment frame can be secured by applying the details of connection of this study results.

본 연구는 춤이 큰 하이브리드 합성보의 1차 휨 성능 평가 후, 2차 연구로써 춤이 큰 하이브리드 합성보와 기둥 접합부의 내진성능평가 실험이다. 실험 변수는 보 춤, 부모멘트 철근 수, 브라켓과 보 이음부의 볼트 수 등으로 3개의 실험체를 제작하였다. 접합부 상세는 기둥에 브라켓을 접합 후, 브라켓에 하이브리드 보를 이음하였다. 브라켓과 보 이음은 하부와 웨브는 볼트접합, 상부는 용접접합하였다. 실험결과 내력은 정 부모멘트 모두 소성모멘트($M_p$) 이상을 확보하였으며, 변형능력은 3% 이상의 층간변위각을 확보하여 합성중간모멘트골조의 요구조건을 만족하는 것으로 나타났다. 그러므로 춤이 큰 하이브리드 합성보에 철골철근콘크리트 기둥을 적용하는 경우 본 연구결과의 접합부상세를 적용하면, 중간모멘트골조의 내진성능을 확보할 수 있다고 판단된다.

Keywords

References

  1. 김성배, 강민정, 조성현, 김상섭(2015) 신개념 하이브리드 합성보의 휨성능 및 내진성능에 관한 실험적 연구, 한국방재학회논문집, 한국방재학회, 제15권, 제4호, pp.1-12. Kim, S.B., Kang, M.J., Cho, S.H., and Kim, S.S. (2015) An Experimental Study on Bending and Seismic Performance of New Concept Hybrid Composite Beam, Journal of the Korean Society of Hazard Mitigation, KOSHAM, Vol.15, No.4, pp.1-12 (in Korean).
  2. 김형섭, 이참남, 이승환, 김법렬(2012) 콘크리트 채움 U형 합성보와 선조립기둥의 내진접합부 성능 실험, 대한건축학회논문집, 대한건축학회, 제28권, 제4호, pp.55-64. Kim, H.S., Lee, C.N., Lee, S.H., and Kim, B.R. (2012) Seismic Performance Test of Concrete-filled U-shaped Steel Beam-to-Prefabricated Column Connections, Journal of Architectural Institute of Korea, AIK, Vol.28, No.4, pp.55-64 (in Korean). https://doi.org/10.5659/JAIK_SC.2012.28.4.55
  3. 허병욱, 곽명근, 배규웅, 정상민(2007) 강판성형 합성보의 휨성능 평가 -춤이 깊은 합성데크-, 한국강구조학회논문집, 한국강구조학회, 제19권, 제3호, pp.247-258. Heo, B.W., Kwak, M.K., Bae, K.W., and Jeong, S.M. (2007) Flexural Capacity of the Profiled Steel Composite Beams-Deep Deck Plate, Journal of Korean Society of Steel Construction, KSSC, Vol.19, No.3, pp.247-258 (in Korean).
  4. 김성배, 이원록, 김정연, 이승배, 유덕수, 김대회, 김상섭 (2012) 신형상 U형 하이브리드 합성보의 휨성능에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제24권, 제5호, pp.521-534.Kim, S.B., Lee, W.R., Kim, J.Y., Lee, S.B., Ryu, D.S., Kim, D.H., and Kim, S.S. (2012) Study on the Flexible Strength of U-shape Hybrid Composite Beam, Journal of Architectural Institute of Korea, AIK, Vol.24, No.5, pp.521-534 (in Korean).
  5. 심현주, 장보라, 정진안, 이은택(2010) 원사이드볼트를 이용한내진각형강관기둥-H형강보접합부의구조성능평가, 한국강구조학회논문집, 한국강구조학회, 제22권, 제4호, pp.355-363. Shim, H.J., Jang, B.R., Chung, J.A., and Lee, E.T. (2010) Performance Evaluation of Connection of Seismic Rectangular Steel Tube Column-H Beam Using One-side Bolts, Journal of Korea an Society of Steel Construction, KSSC, Vol.22, No.4, pp.355-363.
  6. 김성배, 조성현, 오광수, 전용한, 최영한, 김상섭(2016) 춤이 작은 신형상 고성능 하이브리드 합성보의 휨성능 평가, 한국강구조학회논문집, 한국강구조학회, 제28권, 제3호, pp.151-162. Kim, S.B., Cho, S.H., Oh, K.S., Jeon, Y.H., Choi, Y.H. and Kim, S.S. (2014) Bending Performance Evaluation of Hybrid Composite Beam with Low Depth and New Shape, Journal of the Korean Society of Steel Construction, KSSC, Vol.28, No.3, pp.151-162 (in Korean).
  7. 한국강구조학회(2011) 하중 저항계수 설계법에 의한 강구조설계기준 해설, 한국강구조학회. KSSC(2011) Korean Steel Structure Design Code and Commentary-Load and Resistance Factored Design, KSSC (in Korean).
  8. 김영주, 배재훈, 안태상, 장동운(2014) 합성보에 적용된 앵글 전단연결재의 Push-out 실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제3호, pp.155-167. Kim, Y.J., Bae, J.H., Ahn, T.S., and Jang, D.W. (2014) Push-out Test on Welded Angle Shear Connectors used in Composite Beams, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.3, pp.155-167 (in Korean).
  9. Viest, I.M., Colaco, J.P., Furlong, R.W., Griffis, L.G., Leon, R.T., and Wyllie, L.A. (1996) Composite Construction Design for Buildings, McGraw Hill, USA.
  10. Salmon, C.G., Johnson, J.E., and Malhas, F.A. (2008) Steel Structures Design and Behavior, Fifth Edition, Prentice Hall, USA.
  11. 대한건축학회(2009) 건축구조설계기준 및 해설(KBC 2009), 기문당. AIK (2009) Korea building code and commentary structural, Architectural Institute of Korea (in Korean).
  12. 建設省建築硏究所(1996), (社)鋼材俱樂部, "鋼構造物の耐震保有性能評價のための標準試驗方法と評價基準の提案". JISF (1996) A Valuation Basis Proposal of Standard Test Method for a Seismic Capacity Evaluation Performance of Steel Structure, Japan (in Japanese).
  13. FEMA-350 (2000) Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, prepared by the SAC Joint Venture for the Federal Emergency Management Agency, Washington, DC.

Cited by

  1. Development and Seismic Performance Testing of Asymmetric Hybrid Composite Beam-to-Column Connections vol.31, pp.1, 2019, https://doi.org/10.7781/kjoss.2019.31.1.053