Abstract

A beam splice method using inclined end-plates and high-strength tension bolts was developed. The end-plates welded to a bracket and a spliced beam are connected each other by using the tension bolts. In the present study, six exterior beam-to-column moment connections were tested under cyclic loading. Test parameters were the end-plate details and bolt arrangements. All specimens were designed so that moment resistances of the end-plates and bolts were greater than the required moment at the beam splice, in accordance with the design methods of AISC Design Guide 4. Test results showed that in the beam splices with the extended end-plates, the beam moment successfully transferred to the bracket, without any defeats such as excessive prying action of the end plates and brittle failure at the end plate-to-beam flange weld joints. However, the deformation capacities of the overall beam-to-column connections were limited due to the brittle failure of the beam-to-column flange weld joints. From the test results, recommendations for seismic design and detailing of the beam-to-column moment connection with inclined end-plate beam splice were given.

최근 경사단부강판과 고장력 볼트를 이용한 보 이음(Inclined end-plate beam splice) 공법이 개발되었다. 단부강판은 브래킷 단부에 용접되고 연결보는 고장력 볼트를 통해 이음시킨다. 기둥면에는 브래킷이 용접되고, 브래킷과 연결보 단부에 각각 경사단부강판과 고장력 볼트를 이용하여 이음 시킨다. 이 연구에서는 총 6개의 외부 보-기둥 모멘트접합부의 반복가력실험을 수행하였다. 실험변수는 단부강판 상세와 볼트 배열 상세이다. 모든 실험체는 AISC Design Guide 4에 따라 단부강판 및 볼트에 의한 모멘트 저항성능이 보 이음부 요구모멘트보다 크도록 설계되었다. 실험결과, 확장된 단부강판(Extended end-plate)을 사용한 보이음부의 경우 이음부 단부강판의 지레작용 및 볼트의 취성 파단 없이 중앙 보 모멘트가 단부 브래킷으로 효과적으로 전달되었다. 하지만, 보-기둥 접합부의 변형능력은 기둥면 보 플랜지 용접부의 취성파단으로 제한적이었다. 실험결과를 바탕으로, 기울어진 단부강판 이음부를 갖는 보-기둥 모멘트접합부의 내진설계를 위한 개선사항을 제안하였다.

Keywords

References

  1. America Institute of Steel Construction (AISC), Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, ANSI/AISC 358-10, Chicago, 2010.
  2. Sumner, E.A. (2003) Unified Design of Extended End-Plate Moment Connections Subjected to Cyclic Loading, Ph.D. Dissertation, Virginia Polytechnic Institute and State University, Virginia.
  3. Ryan, J.C. (1999) Evaluation of Extended End-Plate Moment Connections Under Seismic Loading, Ph.D. Dissertation, Virginia Polytechnic Institute and State University, Virginia.
  4. Quayyum, S. (2014) Advanced Finite Analysis of Moment Resisting Connections for Improving Seismic Performance and Exploring Effects of Residual Stress and Fire Damage, Ph.D. Dissertation, North Carolina State University, North Carolina.
  5. Ghobarah, A., Korol, R.M., and Osman, A. (1992) Cyclic Behavior of Extended End-Plate Joints, Journal of Structure Engineering, ASCE, Vol.118, No.5, pp.1333-1353. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:5(1333)
  6. Tsai, K.C. and Popov, E.P. (1992) Cyclic Behavior of End-Plate Moment Connections, Journal of Structure Engineering, ASCE, Vol.116, No.11, pp.2917-2930.
  7. Adey, B.T., Grondin, G.Y., and Cheng, J.J.R. (2000) Cycling loading of End Plate Moment Connections, Canadian Journal of Civil Engineering, National Research Council of Canada, Vol.27, No.4, pp.2917-2930.
  8. Korol, R.M., Ghobarah, A., and Osman, A. (1990) Extended End-Plate Connections Under Cyclic Loading: Behavior and Design, Journal of Constructional Steel Research, Elsevier Science Publishers, Vol.16, No.4, pp.253-279. https://doi.org/10.1016/0143-974X(90)90030-K
  9. America Institute of Steel Construction (AISC), Design Guide 4: Extended End-Plate Moment Connections Seismic and Wind Applications (Second Edition), Chicago, 2003.
  10. Morrison, S.J., Astaneh-Asl, A., and Murray, T. (1985) Analytical and Experimental Investigation of the Extended Stiffened Moment End-Plate Connection with Four Bolts at the Beam Tension flange, FSEL/MBMA, 85-05.
  11. 김희동, 양재근, 이형동(2015) 비보강 확장단부판 접합부에 체결된 고장력볼트의 지레작용력 및 축방향 인장강성에 대한 해석적 연구, 한국강구조학회논문집, 한국강구조학회, 제27권, 제2호, pp.251-260. Kim, H.D., Yang, J.G., and Lee, H.D. (2015) Analytical Study on the Prying Action Force and Axial Tensile Stiffness of High-Strength Bolts Used in an Unstiffened Extended End-Plate Connection, Journal of Korean Society of Steel Construction, KSSC, Vol.27, No.2, pp.251-260 (in Korean).
  12. Meng, R.L. (1996) Design of Moment End-plate Connections for Seismic loading, Ph.D. Dissertation, Virginia Polytechnic Institute and State University, Virginia.
  13. Prinz, G.S., Nussbaumer, A., Borges, L., and Khadka, S. (2014) Experimental testing and simulation of bolted beam-column connections having thick extended end plates and multiple bolts per row, Journal of Engineering Structures, Elsevier Science Publishers, Vol.59, pp.434-447. https://doi.org/10.1016/j.engstruct.2013.10.042
  14. 정경수, 김우식, 박만우, 도병호(2010) 밀착조임 볼트체결방법에 따른 엔드플레이트 접합부의 구조성능평가, 한국강구조학회논문집, 한국강구조학회, 제22권, 제2호, pp.121-128. Chung, K.S., Kim, W.S., Park, M.W., and Do, B.H. (2010) Evaluation of Structural Behavior of Tapered Member with Snug-tightened Flush End-Plate Connection, Journal of Korean Society of Steel Construction, KSSC, Vol.22, No.2, pp.121-128 (in Korean).
  15. 이철호, 정종현, 김정재(2014) 철골모멘트 용접접합부의 내진성능에 미치는 합성슬래브의 영향, 한국강구조학회논문집, 한국강구조학회, 제26권, 제5호, pp.385-396. Lee C.H., Jung J.H., and Kim, J.J. (2014) Effects of Composite Floor Slab on Seismic Performance of Welded Steel Moment Connections, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.5, pp.385-396 (in Korean).
  16. Bruneau, M., Uang, C.M., and Whittaker, A. (1998) Ductile Design of Steel Structures, McGraw-Hill, New York.
  17. Chen C.C. and Lin C.C. (2013) Seismic performance of steel beam-to-column moment connections with tapered beam flanges, Journal of Engineering Structures, Elsevier Science Publishers, Vol.48, pp.588-601. https://doi.org/10.1016/j.engstruct.2012.10.003
  18. Mahin, S.A. (1998) Lessons from damage to steel buildings during the Northridge earthquake, Journal of Engineering Structures, Elsevier Science Publishers, Vol.20, No.4-6, pp.261-270. https://doi.org/10.1016/S0141-0296(97)00032-1
  19. Miller, D. K. (1998) Lessons learned from the Northridge earthquake, Journal of Engineering Structures, Elsevier Science Publishers, Vol.20, No.4-6, pp.249-260. https://doi.org/10.1016/S0141-0296(97)00031-X
  20. Seek, M.W., Murray, T.M. (2008) Seismic Strength of Moment End-Plate Connections with Attached Concrete Slab, Proceedings, Connections VI, American Institute of Steel Construction, Chicago, IL, pp.23-25.
  21. Federal Emergency Management Agency, FEMA (2000a), Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, FEMA 350, Washington, DC, 2000.
  22. American Institute of Steel Construction (AISC), Specification for Structural Steel Buildings, ANSI/AISC 360-10, Chicago, 2010.
  23. 이철호, 김성용(2017) 바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강, 한국강구조학회논문집, 한국강구조학회, 제29권, 제1호, pp25-36. Lee C.H. and Kim S.Y. (2017) Seismic Retrofit of Welded Steel Moment Connections Considering the Presence fo Composite Floor Slabs, Journal of Korean Society of Steel Construction, KSSC, Vol.29, No.1, pp.25-36 (in Korean).

Cited by

  1. 각형강관 기둥-H형강 보 신형상 내진접합부의 실험적 평가 vol.30, pp.2, 2017, https://doi.org/10.7781/kjoss.2018.30.2.077
  2. Oversized Hole End-Plate Splice for Columns with Vertical Misalignment vol.31, pp.3, 2019, https://doi.org/10.7781/kjoss.2019.31.3.151