Abstract

Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

Keywords

References

  1. Choi,Gyeong-Seo, On-siteEvaluation forThermalPerformanceofBuilding Envelopesusing an InfraredMethod, Department of Architectural Engineering Graduate School, Hanyang University, 2010
  2. Choi, Bo-Hye, Kang, Jae-Sik, "The Thermal Performance of Building Insulation Materials According to Long-Term Aging, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.25, No. 11, 2013
  3. Park, Se-Young, A study on the improvement of the condensation prevention standards in residential buildings, Department of Convergence Engineering for Future City Sungkyunkwan University, 2014
  4. Jeong, Chan-woul, Kim, Hyun-Soo, Jeong Su-Hyeon, kim, Young-Tak, Song, Doo-sam, Comparison and Analysis of Domestic and Foreign Standards for Preventing the Condensation in Multi-residential House, Korean Journal of Air-Conditioning and Refrigeration Engineering, 2013
  5. PARK, Jung-Hun, An Analysis of Thermal Insulation and a Study of Application of Reinforced Insulation in Apartment Houses, Department of Architectural Material Graduate School of Kong-ju National University, 2014
  6. Moore, Patrick O, "Nondestructive Testing Handbook : Infrared & Thermal Testing, American Society for Nondestructive Testing", 2001
  7. Akira Hoyano, Kohichi Asano, Takehisa Kanamaru, "Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography", Atmospheric Environment 33, 1999