DOI QR코드

DOI QR Code

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul (Department of Radiological Science, Gachon University)
  • Received : 2017.04.10
  • Accepted : 2017.05.11
  • Published : 2017.06.30

Abstract

In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

Keywords

References

  1. P. A. Bottomley and E. R. Andrew, Phys. Med. Biol. 23, 630 (1978). https://doi.org/10.1088/0031-9155/23/4/006
  2. J. T. Vaughan, M. Garwood, C. M. Collins, W. Liu, L. DelaBarre, G. Adriany, P. Andersen, H. Merkle, R. Goebel, M. B. Smith, and K. Ugurbil, Magn. Reson. Med. 46, 24 (2001). https://doi.org/10.1002/mrm.1156
  3. T. S. Ibrahim, R. Lee, B. A. Baertlein, A. M. Abduljalil, H. Zhu, and P. M. Robitaille, Magn. Reson. Imaging 19, 1339 (2001). https://doi.org/10.1016/S0730-725X(01)00404-0
  4. C. M. Collins, W. Liu, B. J. Swift, and M. B. Smith, Magn. Reson. Med. 54, 1321 (2005). https://doi.org/10.1002/mrm.20709
  5. P. F. Van de Moortele, C. Akqun, G. Adriany, S. Moeller, J. Ritter, C. M. Collins, M. B. Smith, J. T. Vaughan, and K. Ugurbil, Magn. Reson. Med. 54, 1503 (2005). https://doi.org/10.1002/mrm.20708
  6. J. Kevin, J. Chang, and I. R. Kamel, Appl. Radiol. 39, 22 (2010).
  7. G. Adriany, P. F. Van de Moortele, J. Ritter, S. Moeller, E. J. Auerbach, C. Akgun, C. J. Snyder, T. Vaughan, and K. Ugurbil, Magn. Reson. Med. 59, 590 (2008). https://doi.org/10.1002/mrm.21488
  8. Y. B. Kim and Y. C. Ryu, Trans. Korean Inst. Electr. Eng. 63, 546 (2014). https://doi.org/10.5370/KIEE.2014.63.4.546
  9. Y. C. Ryu and Y. B. Kim, Trans. Korean Inst. Electr. Eng. 63, 404 (2014). https://doi.org/10.5370/KIEE.2014.63.3.404
  10. Parallel RF Transmission: RF Shimming GUI (http://cai2r.net/resources/software/parallel-rf-transmissionrfshimming-gui)
  11. V. L. Yarnykh, Magn. Reson. Med. 57, 192 (2007). https://doi.org/10.1002/mrm.21120